home > product> solutions > remote i/o modules/units > I-8K & I-87K With different communication interface, the I/O modules can be classified to high communication speed (Parallel bus) 8K series modules and low communication speed (serial interface) 87K series modules. Go to I-8K Series Go to I-87K Series I-8K Series VS I-87K Series
There are two types of I/O modules, Parallel and Serial. The parallel modules (I-8K Series) are high-speed modules and support MCU (Main Control Unit) only. The serial modules (I-87K Series) can support either MCU or I/O expansion unit. The difference between the two series are:Model I-8K Series I-87K Series Communication interface Parallel bus Serial bus Protocol - DCON Communication speed Fast Slow DI with latched function - Y DI with counter input - Y (100 Hz) Power on value - Y Safe value - Y Programmable slew-rate for AO module - Y High Profile VS Low Profile
With different form factor, I/O modules can be classified to high profile and low profile. Basically, high profile and low profile modules that with same item number also have same I/O channel number.
For example: I-8054 and I-8054W both has 8 DI and 8 DO.
Except I/O channel number, other specifications could be different. You have to double check whether the specifications suit your application. For example:
For I-8054W, its DI logic high level is +10~+50V. But for I-8054, it is +3.5~+30V.
The support list of MCU (Main Control Unit) and I/O expansion unit are:I-8K Series VS I-87K Series
There are two types of I/O modules, Parallel and Serial. The I-8K series modules are high-speed modules with parallel interface and the I-87K series are serial interface modules. Both they are supported on PAC (Programmable Automation Controller) units listed in the following table.PAC Description I-8K Series I-87K Series High Profile Low Profile High Profile Low Profile XPAC WES/CE6 OS Y… - Y… - WinPAC CE5 OS Y… - Y… - LinPAC Linux OS Y… - Y… - ViewPAC PAC with Display Y(Note) - Y(Note) - iPAC MiniOS7 OS Y - Y - iPPC-6731-WES7 WES PAC with 15" Touch Panel Y - Y - MP-8000 Motion PAC Y… - - - I-8000 MiniOS7 OS Y Y Y Y I-8K Series VS I-87K Series
The high-speed I-8K series are parallel interface modules and I-87K series are serial interface modules. Both they are supported on PAC-base slave I/O unit. But only I-87K series modules are supported on expansion I/O units like I-87Kn, ET-87Pn, RU-87Pn and USB-87Pn series units.Slave I/O unit Protocol Interface I-8K Series I-87K Series Ethernet RS-485 High Profile Low Profile High Profile Low Profile I-8x10 DCON - 
Y… Y Y… Y I-8x30
I-8KE4/8DCON 

I-8xxx-MTCP
I-8KE4/8-MTCPModbus TCP 

Y… Y Y… Y iP-8xxx-MTCP Modbus TCP 

Y… - Y… - iP-8xxx-MRTU Modbus RTU - 
ET-87P4-MTCP
ET-87P8-MTCPModbus TCP
Modbus RTU
- - - Y… - ET-87P4/8 DCON I-87K4/5/8/9 DCON - 
- - Y… Y RU-87P1/2/4/8 DCON - 
- - Y… - USB-87P1/2/4/8 DCON USB - - Y… - CAN-8xx3 CANopen CAN bus Y… Y… Y… Y… CAN-8xx4 DeviceNet - Y… Y… Y… 
Will be available 
Available soon 
Phased out I-8K series I/O modules Type High Profile
(Software Support)Low Profile Description Analog I/O Modules
(Selection Guide)
I-8014W 
I-8014CW 
I-8017DW 
I-8017HCW I-8017HW 
I-8017HS(Note 1)I-8024W I-8017H I-8024 AI modules have high sampling rate from 1K to 100Ksps (depends on software) Multifunction Modules
(Selection Guide)
I-8026W Digital I/O Modules
(Selection Guide)I-8037 I-8040 I-8041 I-8042 I-8048 I-8050 I-8051 I-8052 I-8053 I-8054 I-8055 I-8056 I-8057 I-8058 I-8060 I-8063 I-8064 I-8065 I-8066 I-8068 I-8069 I-8077 The accessing time can be up to 20KHz (depend on software) Counter/Frequency Module
(Selection Guide)I-8084W I-8080 Input signal range can be 10Hz to 400 KHz PWM Module
(Selection Guide)I-8088W Memory Module/Socket
(Selection Guide)I-8072 I-8072B I-8073 (Note 3) S256 S512 Used to log or retain data. Communication Module
(Selection Guide)I-8112iW I-8114W I-8114iW I-8142iW I-8144iW I-8172W I-8112 I-8114 I-8142 I-8142i I-8144 I-8172 (Note 1) Used to expand RS-232/422/485 and FRnet ports. Ethernet switch module 
I-8135W Used to expand Ethernet connection. Motion Module
(Selection Guide)I-8090W (Note 4) I-8091W (Note 4) I-8092F-G (Note 2) I-8093W I-8094-G (Note 2) I-8094F-G (Note 2) I-8094H-G (Note 1) I-8094A-G (Note 1) I-8090-G (Note 5) I-8091-G (Note 5) Used to drive motors or get encoder data. CAN Bus Modules 
I-8120
(I-8KCAN)I-8120W I-8123W I-8124W 1 Port Programmable CAN Interface Module with Dual Port RAM 1 Port Programmable CAN Interface Module with Dual Port RAM 1 Port High Performance CANopen Master Module 1 Port High Performance DeviceNet Master Module Note 1: Can be used with I-8000, WinCon and LinCon controllers only.
Note 2: Can be used with ISaGRAF in XPAC WinPAC, WinCon, LinPAC, LinCon, I-8000, iPAC-8000,XPAC.
Note 3: Can’t be used with LinCon controllers.
Note 4: Can be used with ISaGRAF or iPAC-8000 only.
Note 5: Can be used with ISaGRAF or I-8000 only.TOP | HOME 
Will be available 
Available soon 
Phased out Other I/O modules Model Description 4SIPP-801-CAB Low profile blank I/O module 4SIPP-801-CAG 4SIPP-801W-CAG High profile blank I/O module TOP | HOME