home > product> solutions > pac > I/O Expansion Unit
 
All I-8000, compact PAC, have similar form factor and system architecture. With different software or communication interface, they can be classfied to several solutions as following
Will be available
Available soon
Will be phased out
Phased out
Modbus RTU I/O Expansion Unit
Modbus is a communication protocol developed by Modicon in 1979 for linking devices with Modicon PLCs using a master/slave relationship. Different versions of Modbus today include Modbus RTU, Modbus ASCII and Modbus TCP. Where Modbus RTU and ASCII are based on serial communication like RS-232 and RS-485, and Modbus TCP is based on Ethernet communication. It's a standard, truly open and widely used in industrial automation field.

The iP-8000-MRTU series is an I/O unit with Modbus protocol. It supports most of high profile I-8K and I-87K series I/O modules. SCADA and HMI software can easily access variant I/O signals via the iP-8000-MRTU.
Model Auto Configuration Hot Swap COM Port Power Supply I/O slot
iP-8411-MRTU Yes - 4 30 W 4
iP-8811-MRTU 8
 
TOP | HOME
Will be available
Available soon
Will be phased out
Phased out
Intelligent RS-485 I/O expansion unit
The unit is used to expand I-87K series I/O modules via the RS-485 interface. It is equipped one power module, one RS-485 interface, one CPU module and several I/O slots. Only high profile I-87K series I/O modules can plug in the unit.

The most important features are
1. Auto configuration
Each slot configuration can be pre-configured and stored in the CPU module, Once a module is plug in, the CPU module will write the pre-configured data to the module.
2. Hot Swap
All I-87K modules circuit design allow it to be hot swapped. The unit don't need to power off while swapping I/O modules.

With above two features, the maintenance becomes very easy. If one module is damaged, the worker just need to find one new module and replace the damaged one. The whole system don't need to shut down for maintenance and the configuration will be done by the CPU module.
Model Auto Configuration Hot Swap Max. baudrate Power Supply I/O slot
  RU-87P1 Yes Yes 115.2 Kbps 5 W 1
  RU-87P2 8 W 2
  RU-87P4 30 W 4
  RU-87P8 30 W 8
 
TOP | HOME
RS-485 I/O expansion unit
The unit only equipped one power module, one RS-485 interface and several I/O slots. It is used to expand I/O modules via the RS-485 interface. Only I-87K and m-87K series I/O modules can plug in the unit.
Model Max. baudrate Power Supply I/O slot
  I-87K4 115.2 Kbps 20 W 4
  I-87K5 5
  I-87K8 8
  I-87K9 9
 
TOP | HOME
Intelligent USB I/O expansion unit
The unit is used to expand I-87K series I/O modules via the USB interface. It is equipped one power module, one USB interface, one CPU module and several I/O slots.

The most important features are
1. Hot Swap
The USB-87Pn doesn’t need to shut down its power to replace or plug I-87K I/O modules. Therefore, the whole system can keep operating without any interruption.
2. Auto configuration
Configurations of I-87K I/O modules can be pre configured and stored in the nonvolatile memory of the USB-87Pn. When the USB-87Pn is power on or an I-87K I/O module is plug in, the USB-87Pn automatically check and restore these configurations to each I-87K I/O modules on it.

Only high profile I-87K module can plug in the unit.
Model Auto Configuration Hot Swap Max. baudrate Power Supply I/O slot
  USB-87P1 Yes Yes 115.2 Kbps 10 W 1
  USB-87P2 15 W 2
  USB-87P4 30 W 4
  USB-87P8 8
 
TOP | HOME
Intelligent Ethernet I/O expansion unit
The unit is used to expand I-87K series I/O modules via the Ethernet. It is equipped one power module, two Ethernet ports, one CPU module and several I/O slots. Only high profile I-87K series I/O modules can plug in the unit.

The most important features are
1. Auto configuration
Each slot configuration can be pre-configured and stored in the CPU module, Once a module is plug in, the CPU module will write the pre-configured data to the module.
2. Hot Swap
All I-87K modules circuit design allow it to be hot swapped. The unit don't need to power off while swapping I/O modules.

With above two features, the maintenance becomes very easy. If one module is damaged, the worker just needs to find one new module and replace the damaged one. The whole system doesn't need to shut down for maintenance and the configuration will be done by the CPU module.
Model Auto Configuration Hot Swap Ethernet Power Supply I/O slot
  ET-87P4 Yes Yes 10/100 BaseTx 30 W 4
  ET-87P8 8
ET-87P4-MTCP Yes Yes 10/100 BaseTx 30 W 4
ET-87P8-MTCP 8
ET-8KP4-MTCP Yes No 10/100 BaseTx 30 W 4
ET-8KP8-MTCP 8
 
TOP | HOME
Modbus TCP I/O Expansion Unit
Modbus is a communication protocol developed by Modicon in 1979 for linking devices with Modicon PLCs using a master/slave relationship. Different versions of Modbus today include Modbus RTU, Modbus ASCII and Modbus TCP. Where Modbus RTU and ASCII are based on serial communication like RS-232 and RS-485, and Modbus TCP is based on Ethernet communication. It's a standard, truly open and widely used in industrial automation field.
The iP-8000-MTCP series is an I/O unit with Modbus protocol. It supports most of high profile I-8K and I-87K series I/O modules. SCADA and HMI software can easily access variant I/O signals via the iP-8000-MTCP.
Model Auto Configuration Hot Swap Ethernet Power Supply I/O slot
iP-8441-MTCP Yes 2 (10/100 BaseTx) 30 W 4
iP-8841-MTCP 8
 
TOP | HOME
Intelligent Remote Redundant Ethernet I/O expansion unit

The unit is the intelligent remote redundant I/O unit with Modbus TCP protocol. It can be equipped with 2 power modules, 2 communication module, 8 I/O modules. The unit offers redundancy options for various functions- ranging from power redundancy to I/O redundancy. Besides, there are most of I/O modules, such as DI, DO, AI, AO, PI, PO, HART and etc, can be used in the units. Only the F-8K modules can be plugged in the unit.

The most important features are
1. Auto configuration
Each slot configuration can be pre-configured and stored in the CPU module, Once a module is plug in, the CPU module will write the pre-configured data to the module.
2. Hot Swap All F-8K modules circuit design allow it to be hot swapped. The unit don't need to power off while swapping I/O modules.
3. Redundancy
Support redundant communication, power and I/O function to enhance the reliability of the system.
4. Open Communication protocol
Due to the Modbus TCP protocol, iDCS-8830 can be integrated in various PC/PAC/PLC system easily.
Model Redundancy Auto Configuration Hot Swap Ethernet Power Supply I/O slot
  iDCS-8830 Yes Yes Yes 10/100 BaseTx 40 W 8
 
TOP | HOME
 
 