main_iconSingle Phase Power Meter

PM-3112 PM-3114 PM-3112-MTCP PM-3114-MTCP
No. of Measurement circuit 2 single phase circuits 4 single phase circuits 2 single phase circuits 4 single phase circuits
No. of Input Voltage 2 2 2 2
No. of Input Current 2 4 2 4
Input Voltage 10 - 300 V
Input Current  Wired clip-on CT,CT Φ10 mm ( 60 A), CT Φ16 mm (100 A), CT Φ24 mm (200 A)
Frequency 50 / 60 Hz
Wiring diagram 1P2W 1P4W 1P2W 1P4W
Power Parameters Measures True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
W Accuracy better than 0.5% (PF=1)
Communication RS485 / Modbus RTU Ethernet / Modubs TCP
Relays Form A (Normal Open) x 2; Relay Contact Voltage Range : 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC


main_iconThree Phase Power Meter
PM-3033 PM-3133 PM-3133-RCT PM-3033-MTCP PM-3133-MTCP PM-3133-RCT-MTCP
No. of Measurement circuit 1 three phase circuits 1 three phase circuits 1 three phase circuits 1 three phase circuits 1 three phase circuits 1 three phase circuits
No. of Input Voltage 1 1 1 1 1 1
No. of Input Current 3 3 3 3 3 3
Input Voltage 10 - 500 V
Input Current 1A or 5A External type CT,
CTØ10 mm (60 A);
CTØ16 mm (100 A);
CTØ24 mm (200 A);
CTØ36 mm (300 A);
CTØ36 mm (400 A)
Rogowski Coil CT,
CTØ55 mm (500 A);
CTØ80 mm (1000 A);
CTØ105 mm (2000 A);
1A or 5A External type CT,
CTØ10 mm (60 A);
CTØ16 mm (100 A);
CTØ24 mm (200 A);
CTØ36 mm (300 A);
CTØ36 mm (400 A)
Rogowski Coil CT,
CTØ55 mm (500 A);
CTØ80 mm (1000 A);
CTØ105 mm (2000 A);
Frequency 50 / 60 Hz
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Power Parameters Measures True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
W Accuracy better than 0.5% (PF=1) Better than 1%
(PF=1;
Input Current >50 A)
better than 0.5% (PF=1) Better than 1%
(PF=1;
Input Current >50 A)
Communication RS485 / Modbus RTU Ethernet / Modubs TCP
Relays - Form A (Normal Open) x 2;
Relay Contact Voltage Range :
5 A @ 250 VAC (47 ~ 63Hz),
5 A @ 30 VDC
- Form A (Normal Open) x 2;
Relay Contact Voltage Range :
5 A @ 250 VAC (47 ~ 63Hz),
5 A @ 30 VDC


main_iconSmart Power Meter with LED Display
PM-2133D PM-2133D-MTCP PM-5133
No. of Measurement circuit 1 three phase circuits
No. of Input Voltage 1
No. of Input Current 3
Input Voltage 10 - 500 V
Input Current PM-2133D-005P: CTØ10 mm (0.05 A ~ 5 A)
PM-2133D-100P: CTØ10 mm (0.05 A ~ 60 A)
PM-2133D-160P: CTØ16 mm (0.1 A ~ 100 A)
PM-2133D-240P: CTØ24 mm (0.15 A ~ 200 A)
PM-2133D-360P: CTØ36 mm (0.3 A ~ 300 A)
PM-2133D-400P: CTØ36 mm (0.3 A ~ 400 A)
PM-5133-005P: CTØ10 mm (0.05 A ~ 5 A)
PM-5133-100P: CTØ10 mm (0.05 A ~ 60 A)
PM-5133-160P: CTØ16 mm (0.1 A ~ 100 A)
PM-5133-240P: CTØ24 mm (0.15 A ~ 200 A)
PM-5133-360P: CTØ36 mm (0.3 A ~ 300 A)
PM-5133-400P: CTØ36 mm (0.3 A ~ 400 A)
Frequency 50 / 60 Hz
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Power Parameters Measures True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
W Accuracy better than 0.5% (PF=1)
Communication RS485 / Modbus RTU Ethernet / Modubs TCP RS485 / Modbus RTU


main_iconMulti-Channel Power Meter
PM-4324 PM-4324A PM-4324-MTCP PM-4324A-MTCP
No. of Measurement circuit 8 three phase circuits or 24 single phase circuits
No. of Input Voltage 1 2 1 2
No. of Input Current 24 24 24 24
Input Voltage 10 - 500 V
Input Current External type CT,
CTØ10 mm (60 A);
CTØ16 mm (100 A);
CTØ24 mm (200 A);
CTØ36 mm (300 A);
CTØ36 mm (400 A)
Frequency 50 / 60 Hz
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Power Parameters Measures True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
W Accuracy better than 0.5% (PF=1)
Communication RS485 / Modbus RTU Ethernet / Modubs TCP
Relays Form A (Normal Open) x 2;
Relay Contact Voltage Range :
5 A @ 250 VAC (47 ~ 63Hz),
5 A @ 30 VDC


main_iconiWSN Power Meter
iWSN-9603-1P / iWSN-9603-3P
No. of Measurement circuit 2 three phase circuits or 4 single phase circuits
No. of Input Voltage 1
No. of Input Current 4(Single Phase) / 2(Three Phase)
Input Voltage Three phase 4 wire x1, 100 - 480 VAC (58 - 277 VAC single phase)
Input Current
External type CT Rogowski Coil CT
CTØ16 mm (100 A) CTØ55 mm (500 A)
CTØ24 mm (200 A) CTØ80 mm (1000 A)
CTØ36 mm (400 A) CTØ105 mm (2000 A)
Frequency 50 / 60 Hz
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Power Parameters Measures True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Power Factor (PF)
W Accuracy better than 1% (PF=1)
RF
Channels 0 ~ 15
Group ID 0 ~ 3
Radio Frequency 433.1000 ~ 434.6000 MHz
Transmission Power 9±1dBm (PA Off) / 18±1dBm (PA On)
Transmission Distance (LoS) 100 m
Node ID 1 ~ 31
Working Duty 1, 10, 30, or 60 Seconds