| All I-8000, compact PAC, have similar form factor and system architecture. With different software or communication interface, they can be classfied to several solutions as following |
 |
Will be available |
 |
Available soon |
 |
Will be phased out |
 |
Phased out |
|
|
| |
|
|
8000 Series ISaGRAF based PAC (Programmable Automation controller)
The controller fully supports all five of the IEC61131-3 standard PLC languages:
1. Ladder diagram.
2. Function block diagram.
3. Sequential function chart.
4. Structured text.
5. Instruction List plus flow chart.
It supports Modbus protocol and can link to distributed I/O modules with Modbus or DCON protocol via the RS-232/485 or Ethernet. |
| Model |
I/O Slot |
CPU |
SRAM |
Flash |
Memory Expansion |
Ethernrt |
RS-232/485 |
| |
I-8417 |
4 |
40 MHz |
512 KB |
512 KB |
– |
1 (10-Base-T) |
4 |
| |
I-8817 |
8 |
| |
I-8437 |
4 |
40 MHz |
512 KB |
512 KB |
– |
1 (10-Base-T) |
3 |
| |
I-8837 |
8 |
| |
I-8437-80 |
4 |
80 MHz |
| |
I-8837-80 |
8 |
| |
 |
iP-8417 |
4 |
80 MHz |
768 KB |
512 KB |
microSD |
– |
4 |
 |
iP-8817 |
8 |
 |
iP-8447 |
4 |
80 MHz |
768 KB |
512 KB |
microSD |
2 (10/100 Base-Tx) |
4 |
 |
iP-8847 |
8 |
|
| |
|
|
8000 Series Matlab based PAC (Programmable Automation controller)
Matlab/Simulink is very powerful and flexible software for technical computing, which includes modeling, simulating, analyzing dynamic system , etc. Simulink provides a graphical user interface (GUI) for building models as block diagram by click-and-drag mouse operation. And Real-Time Workshop based on Matlab/Simulink supplies a real-time development environment—an approach from system design to hardware implementation. You can shorten development cycles and reduces costs with real-time workshop by testing design iteration on target hardware. |
| Model |
I/O Slot |
CPU |
SRAM |
Flash |
Memory Expansion |
Ethernrt |
RS-232/485 |
| |
I-8438-G |
4 |
80 MHz |
512 KB |
512 KB |
– |
1 (10-Base-T) |
3 |
| |
I-8838-G |
8 |
|
| |
|
|
 |
Slave I/O unit with DCON protocol
DCON protocol is a very simple and easy used ASCII based protocol. It is suit master-slave or query-response distributed I/O applications. The unit is pre-installed a DCON firmware. Therefore PC, HMI or PLC can uses DCON protocol to communicate with I/O modules in the unit via the RS-232/485 or Ethernet interface. |
| Model |
I/O Slot |
CPU |
SRAM |
Flash |
Memory Expansion |
Ethernrt |
RS-232/485 |
| |
I-8410 |
4 |
40 MHz |
256 KB |
256 KB |
– |
– |
3 |
| |
I-8810 |
8 |
| |
I-8430 |
4 |
512 KB |
512 KB |
1 (10-Base-T) |
| |
I-8830 |
8 |
| |
I-8KE4-G |
4 |
80 MHz |
1 |
| |
I-8KE8-G |
8 |
|
| |
|
|
 |
Programmable slave I/O unit with Modbus protocol
Modbus is very wide known protocol in the industrial manufacturing and environment monitoring fields. It is suit master-slave or query-response distributed I/O applications. The unit is pre-installed a Modbus firmware. Therefore PC, HMI or PLC can use Modbus/TCP and Modbus/RTU protocol to communicate with I/O modules in the unit via the RS-232/485 or Ethernet interface.
Besides the slave I/O functionality, it is also a c language based programmable controller that equipped a DOS-like OS (MiniOS7). Users can use C compilers that can create 16 bit executable file (*.exe) to develop a program then download it to the controller. That let the controller work stand alone. There are two free charge version compilers (Turbo C 2.0 and Turbo C++ 1.01), we suggest users to use the Turbo C++ 1.01.
Using the software development toolkits that we provide can customize the firmware. The SDK provides rich functions for Modbus communication, such as Modbus/TCP master/slave, Modbus/RTU master/salve, Modbus/ASCII master, etc. |
| Model |
I/O Slot |
CPU |
SRAM |
Flash |
Memory Expansion |
Ethernrt |
RS-232/485 |
| |
I-8431-MTCP |
4 |
40 MHz |
512 KB |
512 KB |
– |
1 (10-Base-T) |
3 |
| |
I-8831-MTCP |
8 |
| |
I-8431-80-MTCP |
4 |
80 MHz |
| |
I-8831-80-MTCP |
8 |
| |
I-8KE4-MTCP-G |
4 |
1 |
| |
I-8KE8-MTCP-G |
8 |
|
| |
|
|
|
| |
|
| |
| |