MN-DA2-DIN is a Motionnet 2-channel analog output I/O module. The max device capacity can be loaded 64 I/O modules on each Motionnet
communication port. Thus, each port can be expended into 128 analog output points at once. The communication latency between
two devices is 15.1 μsec so that the max communication latency with 64 I/O modules on one communication port is 0.97 ms. The
I/O connection status update is automated and real-time by hardware without occupied CPU time. The 16 bit high precision resolution
analog output is provided +/- 10V range, 5V reference voltage with low shift, and hardware calibration in offset and gain for easy usage
to customers. |