Introduction
It's a fact that the PC hardware and software may fail. To prevent the failure,many different solutions are proposed. However, none of these solutions offer a 100% assurance. Since it's hard to prevent the failure, to detect the failure becomes more and more important. The WDT-03 is used to detect the failure of the software and hardware. It can be used to reduce the risk of PC failure. The WDT-03 is useful even for those systems with built-in watchdog circuit.
The WDT-03 is equipped with two RS-232 ports, one is master port and another one is slave port. The master RS-232 port is designed to communicate with the local host-PC. The local host-PC can enable/disable/refresh/read-back the watchdog timer through the master RS-232 port. The slave RS-232 is used to send information to the remote Host-PC for monitoring. SO the remote HOST will get information immediately if the local host-PC has any software or hardware problem, even the power is failure
The WDT-03 is equipped with two RS-232 ports, one is master port and another one is slave port. The master RS-232 port is designed to communicate with the local host-PC. The local host-PC can enable/disable/refresh/read-back the watchdog timer through the master RS-232 port. The slave RS-232 is used to send information to the remote Host-PC for monitoring. SO the remote HOST will get information immediately if the local host-PC has any software or hardware problem, even the power is failure
Applications
- Factory Automation
- Product Test
- Laboratory Automation


Ordering Information
| PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
|---|---|---|---|
This combination include other products.
Similar Products
| Software | |
|---|---|
| Utility | Support Utility for DOS, 95/98/Me/2000/NT |
| Memory | |
|---|---|
| Type | EEPROM |
| Size | 63 bytes for user read/write, read/write cycles : 100,000 times |
| Watchdog | |
|---|---|
| Watchdog Timer | Software enable/disable watchdog timer; From 0.03 second to 1966.05 seconds |
| Bus Voltage Monitoring | 3.3V , 5V , 12V , -5V , -12V |
| Temperature Monitoring | 3 channels |
| Fan Speed Monitoring | 3 channels |
| PC Bus | |
|---|---|
| Type | ISA/PCI bus for PC and any System with RS-232 interface |
| COM Ports | |
|---|---|
| Ports | 1 x RS-232 (local CPU) 1 x RS232 (remote HOST(monitor the local CPU)) |
| Baud Rate | 2.4K, 4.8K, 9.6K, 19.2K, 38.4K, 57.6K, 115.2K |
| Data Format | N,8,1 |
| Protocol | DCON Protocol |
| Power | |
|---|---|
| Consumption | 2 W |
| Mechanical | |
|---|---|
| Dimensions (mm) | 140 mm x 70 mm |
| Environment | |
|---|---|
| Operating Temperature | 0 ~ +60°C |
| Storage Temperature | -20 ~ +75°C |