End of Life Notification for TPD-433F
- EOL notification date: 2017/11/17
Phased out model: TPD-433F
Last Order Date: Subject to availability (limited in quantity while stocks last)
Dear Partners,
ICP DAS hereby formally announces the manufacturing discontinue and End of Life (EOL) of TPD-433F.
Within the effective warranty period, ICP DAS is committed to continue providing comprehensive after-sales service and technical support.
● Reason for termination: Phase out of MCU
● Suggested replacement device: TPD-433F-H
- Status: Available
- Please refer to the following table for cross reference information. -
Model NameTPD-433FTPD-433F-HProduct StatusPhased outAvailableCPU32-bit RISC CPU32-bit RISC CPUMiniOS8Yes (update required)-Memory Expansion16 MB SDRAM/8 MB Flash16 MB SDRAM/16 MB FlashReal Time Clock (RTC)YesYesBuzzerYesYesRotary Switch (0~9)YesYesLCD4.3 TFT (Resolution 480 x 272, 65536 colors)4.3 TFT (Resolution 480 x 272, 65536 colors)Serial PortCOM1: RS-485
COM2: RS-232COM1: RS-485
COM2: RS-232Firmware updatesUSB 1.1 ClientUSB 1.1 Client or EthernetEthernetRJ-45 x 1, 10/100 Base-TXRJ-45 x 1, 10/100 Base-TXPowered from PoEIEEE 802.3af, Class1 (48 V)IEEE 802.3af, Class1 (48 V)Powered from Terminal Block+10 ~ +30 VDC+12 ~ +48 VDCReset ButtonYesYes -
Migrating projects from TPD-433F to TPD-433F-H:
1. Open original project by using HMIWorks v2.10.22 or last version.
2. Click the HMIWorks menu item "Project/Project Configuration". - 3. Click the "General" page and select the “TPD” option.
4. Change the "TouchPAD Type" to TPD-433F-H. - If your original project uses Ladder program, and is created by HMIWorks v2.09.09 or older versions, please follow the steps 5 - 6 to disable the new Ladder mode.
New ladder mode: The Coil-Set and Coil-Reset change the coil state and lock it (industrial standard) until reset or set. Other coil operations will not unlock or change it.
Old ladder mode: There is no lock feature.
5. Click the "Others" page.
6. Unchecked the "Use New Ladder Implementation” item in the “Ladder” pane.
7. Click "OK" button. - 8. Click the HMIWorks menu item "Run/Build (Render, Compile)" to rebuild project or press F5.
-