UA-5231 Series IIoT Communication Server Release New Version V.1.3.3.2

Product Update 2021-09-27


 

UA Series Release New Version V1.3.3.2:

The UA series IIoT Communication Server releases the new version of V1.3.3.2. It upgrades the storage and communication port on the hardware specifications and adds four new functions on the firmware side. Also, the data security functions and some errors have improved. This new version will optimize your project design and product application. Welcome to try our live demo and consult with us.
(Support 512MB Flash version update)
 

Hardware Upgrade: 

1. Storage Upgrade: The Flash enlarge from 512 MB to 8 GB for the model UA-5231/5231M.
2. Communication Port Upgrade: Add one more RS-485 Serial port to have the 2500 VDC isolated function. Now, both RS-485 Serial ports are the isolated ports. It can help block noise interference and protect field equipment and application projects. 
 
Model OS CPU SDRAM Flash FRAM microSD Card Ethernet Port USB Port RS-232/
RS-485
Wireless
UA-5231 Linux Kernel 3.2.14 ARM CPU, 1.0 GHz DDR3 512 MB 8 GB 64 KB 4 GB
(Max. 32 GB microSDHC)
1 1 4
(Isolated RS-485 x 2)
-
UA-5231M -
UA-5231M-4GC 4G
UA-5231M-4GE
UA-5231M-3GWA 3G
 
UA-5231: IIoT Communication Server with 1 Ethernet Port, Plastic Case
UA-5231M: IIoT Communication Server with 1 Ethernet Port, Metal Case
UA-5231M-4GE: IIoT Communication Server with 1 Ethernet Port, Metal Case, 4G LTE (FDD) Wireless Communication
UA-5231M-4GC: IIoT Communication Server with 1 Ethernet Port, Metal Case, 4G LTE (FDD, TDD) Wireless Communication
UA-5231M-3GWA: IIoT Communication Server with 1 Ethernet Port, Metal Case, 3G Wireless Communication
 

Firmware New Functions: 

1. Function of Module Communication Conversion: Add Internal Module converting with OPC UA
This function can create virtual internal variables and put them into the OPC UA Server to provide data exchange of multiple OPC UA Clients. Using this function, the user can achieve the Client to Client data communication conversion. 




2. Module List for Modbus Mapping Table: Add more models into the Module List, such as WISE, ET/PET, DL, tM series modules
In the Modbus RTU and Modbus TCP Module Setting, more WISE, ET/PET, DL, tM series and models are added into the Module List. With one clicking on a model of Module List, the system will create the complex Modbus Address Mapping Table quickly, easily, automatically for the users, saving more time and effort. The users can download the latest ICP DAS Module List from the Firmware webpage of the UA Download Center. And upload ICP DAS Module List in the menu of the Module Setting of the UA Web UI.




3. Variable type: Support Int64 data type
This new function supports Modbus devices with the 64-bit Integer data type, such as electricity meters, water meters, etc. It allows users to design the projects more diversified and can apply the UA series into more advanced applications.




4. Remote Database MySQL / MS SQL / MariaDB: Add Data Change mode for Data Logger setting
The user can select to write the log data into the database when the data changes. If the data do not change, the system will not spend the resources to write. Which not only saves the resources but also improves the performance. In addition, it also provides the option of merging or separating the [Date Time Format] field, which is more compatible with the database table design.



 

Live Demo:

ICP DAS provides trial Live Demo of UA series. Please refer to below linkage and try the Live demo of UA Series Communication Server. Or http://122.147.137.139/ (Username: root, Password: root)




 

More websites:

UA series Website :
http://www.icpdas.com/en/product/guide+IIoT+Controller_Server+Communication__Server#534 

UA Download Center > Firmware – Download the Firmware and the Module List 
https://www.icpdas.com/en/download/show.php?num=1135&nation=US&kind1=&model=&kw=ua- 

UA Brochure – IIoT Cloud Solution: UA Series IIoT Communication Server 
https://www.icpdas.com/en/download/show.php?num=1260&kind=19