~ New ~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Running HMI and Control Logic in the Same PAC |
 |
New!! |
 |
Trend and Gauge meter |
 |
Alarm Lists |
|
|
|
|
|
|
|
|
|
|
|
|
XP-8x47-Atom-CE6 Series are the new generation ISaGRAF based PACs of ICP DAS. It is equipped with an Atom Z510 1.1 GHz CPU, various connectivity (VGA, USB, Ethernet, RS-232/485) and 1/3/7 I/O slots for high performance parallel I/O modules (high profile I-8K Series) and serial I/O modules (high profile I-87K series).
The benefits of running Windows CE 6.0 on XPAC include hard real-time capability, small core size, fast boot speed, interrupt handling at a deeper level and achievable deterministic control. XPAC is also capable of running ISaGRAF and PC-based control software such as Visual Basic .NET, Visual C#,…. etc. It has all of the best features of both traditional PLCs and Windows capable PCs.
Major advantage compared with the WP-8xx7 and VP-2xW7 :
• The USB-mouse operations and Ethernet communication of the XP-8xx7-Atom-CE6 are more effective
(consume less CPU loading) than the WP-8xx7 and VP-2xW7.
• The memory size (Flash and SDRAM) of the XP-8xx7-Atom-CE6 is much more than the WP-8xx7 and VP-2xW7.
The XPAC Series XP-8xx7-Atom-CE6 supports ISaGRAF Ver. 3 Workbench:
• IEC 61131-3 Standard Open PLC Programming Languages (LD, FBD, SFC, ST, IL, FC) + Flow Chart (FC)
• Auto-Scan I/O
• On-Line Debugging/Control/Monitoring, Off-Line Simulation
• Simple Graphic HMI |
|
|
|
|
|
|
|
|
|
|
|
|
|
Windows Compact Edition 6.0 |
.NET Compact Framework 3.5 |
ISaGRAF Ver.3 SoftLogic Inside |
Support IEC 61131-3 Standard |
Support Soft-GRAF HMI |
Support connect to Microsoft Server |
Accepts max. 2 MB ISaGRAF code size |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CPU: Atom Z510, 1.1 GHz |
More Effective USB & Ethernet than WP-8xx7 |
512 MB DDR SDRAM, 2 GB Built-In Flash |
Battery Backup SRAM: 512 KB |
System Rescue CF Card (Disaster Recovery System) |
1/3/7 I/O Expansion Slots (support High Profile I/O Modules) |
Dual Ethernet Ports (10/100M/1G) |
4 Serial Ports (RS-232/RS-485) |
Redundant Power Inputs |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Models |
XP-8047-Atom-CE6 |
XP-8347-Atom-CE6 |
XP-8747-Atom-CE6 |
System Software |
OS |
Windows CE 6.0 R3 Core |
.Net Compact Framework |
3.5 |
Embedded Service |
FTP Server, ASP (Java Script, VB Script), SQL Compact Edition 3.5 |
SDK Provided |
Dll for Visual Studio .Net 2005/2008 |
Multilanguage Support |
English, German, French, Spanish, Russian, Italian, Czech, Japanese, Korean, Simplified Chinese, Traditional Chinese |
Development Software |
ISaGRAF Software |
ISaGRAF Ver.3 |
IEC 61131-3 standard |
Languages |
LD, ST, FBD, SFC, IL & FC
Support Soft-GRAF HMI : XP-8xx7-CE6, XP-8xx7-Atom-CE6, WP-8xx7/5xx7 and VP-2xW7/4xx7 PAC |
Max. Code Size |
2 MB |
Scan Time |
3 ~ 15 ms for normal program
15 ~ 50 ms (or more) for complex or large program |
Non-ISaGRAF |
Options: VS.NET 2005/2008 (VB.NET, C#.NET) |
Web Service |
Web HMI |
PC running Internet Explorer can monitor/control PAC via Internet/modem |
Security |
Web HMI supports three levels username and password protection. (high/middle/low) |
CPU Module |
CPU |
Atom Z510, 1.1 GHz |
System Memory |
512 MB DDR SDRAM |
Dual Battery Backup SRAM |
512 KB; data valid up to 5 years (for retain variables) |
Flash |
2 GB as IDE Master |
EEPROM |
16 KB |
CF Card |
Yes, support up to 32 GB |
Programmable LED Indicator |
2 |
RTC (Real Time Clock) |
Provide second, minute, hour, date, day of week, month, year |
64-bit Hardware Serial Number |
Yes, for Software Copy Protection |
Dual Watchdog Timers |
Yes |
Rotary Switch |
Yes (0 ~ 9) |
DIP Switch |
Yes (8 bits) |
Audio |
Microphone-In and Earphone-Out |
VGA & Communication Ports |
VGA |
Yes, (resolution: 1400 x 1050, 1024 x 768, 800 x 600, 640 x480) |
Ethernet |
RJ-45 x 2, 10/100/1000 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
USB 2.0 |
4 |
COM 1 |
Internal communication with the high profile I-87K series modules in slots |
COM 2 |
RS-232 (RxD, TxD and GND); non-isolated |
COM 3 |
RS-485 (Data+, Data-) with internal self-tuner ASIC; 3000 VDC isolated |
COM 4 |
RS-232/RS-485 (RxD, TxD, CTS, RTS and GND for RS-232, Data+ and Data- for RS-485);
non-isolated |
COM 5 |
RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated |
I/O Expansion Slots |
Slot Number |
1 |
3 |
7 |
Note: For High Profile I-8K and I-87K Modules Only |
Mechanical |
Dimensions (W x L x H) |
169 x 132 x 125 mm |
231 x 132 x 125 mm |
355 x 132 x 125 mm |
Installation |
DIN-Rail or Wall Mounting |
Environmental |
Operating Temperature |
-25 ~ +75°C |
Storage Temperature |
-30 ~ +80°C |
Ambient Relative Humidity |
10 ~ 90% RH (non-condensing) |
Power |
Input Range |
+10 ~ +30 VDc |
Isolation |
1 kV |
Redundant Power Inputs |
Yes, with one power relay (1 A @ 24 VDC) for alarm |
Capacity |
25 W |
35 W |
35 W |
Consumption |
16.6 W |
16.8 W |
18 W |
|
|
|
Protocols (some protocols need optional devices) |
Net ID |
1 ~ 255, user-assigned by software |
Modbus TCP/IP Master |
Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol (FAQ-113) |
Modbus RTU/ASCII Master |
Max. 32 Ports : COM2 ~ 33 (To connect to other Modbus Slave devices). (*) |
Modbus RTU Slave |
Max. 8 Ports : COM2 ~ 33 (For connecting ISaGRAF, PC/HMI/OPC Server & HMI panels). (*) |
Modbus TCP/IP Slave |
2 Ethernet Ports all support Modbus TCP/IP Slave protocol for connecting ISaGRAF & PC/HMI.
2 Ports support up to 64 connections.
Note: If PAC uses 1 connection to connect each PC/HMI, it can connect up to 64 PC/HMI; If PAC uses 2 connections to connect each PC/HMI, it can connect up to 32 PC/HMI; When one Ethernet port is broken, the other one can still connect to PC/HMI. |
Web HMI Protocol |
Ethernet Ports for connecting PC running Internet Explorer. |
User-Defined Protocol |
Write own protocol applied at COM2 ~ 33 by Serial communication function blocks. (*) |
I-7000 & I-87K RS-485 Remote I/O |
One of COM3 ~ 4 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards or RU-87Pn
+
I-87K High Profile I/O boards as remote I/O.
Max. 255 modules of I-7000/87K Remote I/O for one PAC. |
M-7000 Series Modbus I/O |
Max. 32 RS-485 ports. Each port can connect up to 32 M-7000 Modules. (*) |
Modbus TCP/IP I/O |
LAN2 supports ICP DAS Ethernet I/O : I-8KE4-MTCP and I-8KE8-MTCP. If LAN2 is broken, it will switch to LAN1 automatically to continuously work. (This need LAN1 & LAN2's IP are set in the same IP domain) (FAQ-042) |
FRnet I/O |
Support max 7 pcs. I-8172W boards in slot 1 ~ 7 to connect to FRnet I/O modules, like FR-2053, FR-2057 FR-32R, FR-32P.
Each I-8172W board can link max. 256 DI plus 256 DO ch. (FAQ-82 and FAQ-154) |
Send Email |
Supports functions to send Email with one attached file via Ethernet port. |
Ebus |
To exchange data between ICP DAS's ISaGRAF Ethernet PACs via Ethernet port. (LAN2 Port only) |
SMS: Short Message Service |
COM4 or COM5 can link to a GSM Modem to support SMS. User can request data/control the controller by cellular phone. The controller can also send data & alarms to user's cellular phone.
Optional GSM Modem: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem) or other GSM/GPRS Modem. |
MMICON/LCD |
COM4 or COM5 supports ICP DAS's MMICON. |
UDP Server & UDP Client :
Exchange Message &
Auto-Report |
LAN1 or LAN2 support UDP Server and UDP Client protocol to send/receive message to / from PC/HMI or other devices.
For example, to automatically report data to InduSoft's RXTX driver. |
TCP Client :
Exchange Message &
Auto-Report |
LAN1 or LAN2 support TCP Client protocol to send / receive message to / from PC/HMI or other devices which support TCP server protocol. |
GPRS/SMS |
Support the I-8212W (2G/3G) card to receive/send a short message or to dial up to link the Internet by GPRS connection to send an email or communicate with remote stations by using "Ftp Client" (FAQ-151) and "TCP Client" / "UDP Server" / "UDP Client" (FAQ-143). |
SQL Client |
Support SQL Client function to write data to (or read data from) Microsoft SQL Server (2000 SP3, 2005, 2008). |
Hot-Swap and Redundant System
(Will be available) |
This redundant system has setup two “Active IP” address point to the active LAN1 and LAN2 ports always. One or more PC/HMI/SCADA can communicate with this redundant system via one of the two given active IP. So the PC/HMI/SCADA can access to the system easily without any notice about which PAC is currently active.
Moreover, the new redundant system can integrate with the RU-87P4/87P8 Expansion Unit plus the I-87K high-profile I/O cards to support the hot-swap application. If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system. (FAQ-138 and FAQ-125) |
CAN/CANopen |
COM2, 4 ~ 33 (*) to connect one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One PAC supports max.32 RS-232 ports to connect max.32
I-7530. (FAQ-086) |
CANopen Master |
Support the I-8123W CANopen Master card to connect other CANopen slave devices. (FAQ-145) |
HART Solutions |
Support I-87H17W modules in slot 1 to 7 to communicate with other HART devices. |
FTP Client |
Support FTP client to upload files in the PAC to a remote FTP server on PC. (FAQ-151)
Soft-GRAF’s g_Alarm & g_Logger1 HMI objects support FTP client, too. (FAQ-146) |
Soft-GRAF HMI |
Support the Soft-GRAF HMI . User can use the Soft-GRAF Studio on the PC to design the HMI screen and then download it to the PAC to display the HMI on the PAC. (FAQ-146) |
Optional I/O Functions (Refer to ISaGRAF PAC I/O Selection Guide for I/O Module list) |
PWM Output |
High Speed PWM Module |
I-7088, I-8088W, I-87088W: 8-ch PWM outputs, software support 1 Hz ~ 100 kHz
(non-continuous), duty: 0.1 ~ 99.9% |
DO Module as PWM |
88-ch max. 250 Hz max. For Off=2 & On=2 ms. Output square wave: Off: 2 ~ 32766 ms,
On: 2 ~ 32766 ms.
Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave) |
Counter, Encoder, Frequency |
Parallel DI Counter |
8 ch. max. for 1 controller. Counter val: 32 bit. 250 Hz max. Min. ON & OFF width must >2 ms.
Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W. |
Serial DI Counter |
Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16 bit)
Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W. |
Remote DI Counter |
All remote I-7000 & I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535 |
High Speed Counter |
I-87082W: 100 kHz max. 32 bit;
I-8084W: 250 kHz max. 32 bit |
Encoder |
I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4 MHz for
pulse/direction and cw/ccw input mode. (FAQ-112)
I-8084W: 250 kHz max., 4-ch encoder, pulse/direction or up/down or A/B phase (Quad. mode).
Not support Encoder Z-index. (FAQ-100) |
Frequency |
I-87082W: 2-ch, 1 Hz ~ 100 kHz;
I-87088W: 8-ch, 0.1 Hz ~ 500 kHz;
I-8084W: 8-ch, 1 Hz ~ 250 kHz; |
Motion |
Motion Control |
Integrate with one or several I-8092F (2-axis) or I-8094F/I-8094 (4-axis) |
* Note: COM6 ~ COM33 are resided at the expansion boards if they are plugged on slot 1 ~ 7 of XP-8xx7-Atom-CE6.
XP-8xx7-Atom-CE6's COM1 is for internal communication with I-87K modules in slots only.
* ISaGRAF FAQ: http://www.icpdas.com/faq/isagraf.htm
* Recommend to use NS-205/NS-208 or RS405/RS408 Industrial Ethernet Switch. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
XP-8147-Atom-CE6 CR |
1 slots Ethernet WinCE 6.0 Based ISaGRAF XPAC-Atom (RoHS) |
(OS: Multi-language version) |
XP-8347-Atom-CE6 CR |
3 slots Ethernet WinCE 6.0 Based ISaGRAF XPAC-Atom (RoHS) |
(OS: Multi-language version) |
XP-8747-Atom-CE6 CR |
7 slots Ethernet WinCE 6.0 Based ISaGRAF XPAC-Atom (RoHS) |
(OS: Multi-language version) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Click here to see more ISaGRAF PAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|