    PROFIBUS/Modbus Gateway

     
     

    The GW-7552 Gateway is specially designed for the slave device of PROFIBUS DP protocol. It allows the PROFIBUS master to access the Modbus devices. These Modbus devices may be a PLC, a sensor, ICPDAS M-7000 series modules and so forth. In addition, we also provide the utility software for users to configure the GW-7552. By using this module, users can put their Modbus devices into PROFIBUS network very easily.

     
     
    Applications  
    • Industrial Automation
    • Factory Automation
    • Process Automation
    • Etc…
     
     
    Features  
    Protocol & Hierarchy
    DP-V0 Slave
    Supports PROFIBUS Transmission Rate (Kbps)
    9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000
    Transmission Rate Setting
    detected automatically
    Max Input Data Length
    132 Bytes
    Max Output Data Length
    131 Bytes
    Address Setting
    0~126 set by DIP switch
    Supports Modbus Mode
    Master/Slave
    Supports Modbus Format
    RTU/ASCII
    Hybrid COM 1
    RS-232/422/485 with “Self Tuner” inside
    Supports COM 1 Baudrate (Kbps)
    2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2
    Supports COM 1 Data Format
    7/8 data bits, No/Odd/Even parity, 1/2 stop bit
    Indicators
    PWR, ERR, and RUN LEDs
    Network Isolation Protection
    High Speed iCoupler
    DC Isolation Protection
    3000VDC on PROFIBUS side
     
     
    Utility  
    The GW-7552 Utility helps users to configure the devices, and has following features:
    • Provide GW-7552 safe value setting
    • Display module parameters of the GW-7552
    • Show module address configuration of the GW-7552

     

     
     
    Modules Support  
    Only the following Modbus commands are supported by the gateway.
    Code
    Name
    Description
    01
    Read Coil Status
    Read the ON/OFF status of discrete outputs in the slave
    02
    Read Input Status
    Read the ON/OFF status of discrete inputs in the slave
    03
    Read Holding Registers
    Read the binary contents of holding registers in the slave
    04
    Read Input Registers
    Read the binary contents of input registers in the slave
    05
    Force Single Coil
    Write a single output to either ON or OFF in the slave
    06
    Preset Single Register
    Write an integer value into a single register in the slave
    15
    Force Multi. Coils
    Write each coil in the sequence of coils to either ON or OFF in the slave
    16
    Preset Multi. Registers
    Write a block of contiguous registers in the slave
     
     
    Hardware Specifications  
    Hardware
    CPU
    80186, 80 MHz or compatible
    SRAM/Flash/EEPROM
    512 KB / 512 KB / 16 KB
    Watchdog
    Watchdog IC
    CPU built-in
    ESD Protection
    4 kV class A
    PROFIBUS Interface
    Controller
    Siemens SPC3
    Transceiver
    ADI ADM2486
    Connector
    9-pin female D-Sub
    Baud Rate (bps)
    9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M
    Transmission Distance (m)
    Depend on baud rate (for example, max. 1200 m at 9.6 kbps )
    Isolation
    3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic
    Protocol
    DP-V0
    UART Interface
    COM
    RS-232/RS-422/RS-485(can’t be used simultaneously)
    COM Connector
    3-pin screwed terminal block (RxD, TxD, GND)
    4-pin screwed terminal block (RxD+, RxD-, TxD+, TxD-)
    2-pin screwed terminal block (DATA+, DATA-)
    Baud Rate (bps)
    1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
    Data bit
    7, 8
    Stop bit
    1, 2
    Parity
    None, Even, Odd
    LED
    Round LED
    PWR LED, RUN LED, ERR LED
    Power
    Power supply
    Unregulated +10 ~ +30 VDC
    Protection
    Power reverse polarity protection, Over-voltage brown-out protection
    Power Consumption
    2.5 W
    Mechanism
    Installation
    DIN-Rail
    Dimensions
    72 mm x 33 mm x 119 mm (W x L x H)
    Environment
    Operating Temp.
    -25 ~ 75℃
    Storage Temp.
    -30 ~ 85℃
    Humidity
    5 ~ 95% RH, non-condensing
     
     
    Ordering Information  
    GW-7552-B CR
    PROFIBUS/Modbus Gateway (RoHS)
    GW-7552-M CR
    PROFIBUS/Modbus Gateway (RoHS) (Metal casing)
     
       