AR-200/AR-400 (Accelerometer Data Logger)
New Products
2018-03-29

In recent years, in the trend of rapid growing in intelligent factory, automatic, unmanned, and intelligent equipment would be the main trend in the future. The vibration detection of equipment could prevent the loss caused by the damage of equipment. The factory manager could perform maintenance and repair before the equipment being out of order due to lacking of maintenance in time. And it prevent large scale malfunction of the equipment which may by decrease the production efficiency.
IEPE acceleration sensor in current market is often used in detection of vibration signal in station bearing, and it usually needs to install extra driver module. In this way, the cost is increase and may cause uncertain results in measurement. In addition, the sampling range of acceleration recorder in current market usually could not meet the standard to detect certain range of vibration for station bearing. In order to solve the above problem and to achieve best performance, ICP DAS has developed Accelerometer Data Logger, AR-200/AR-400.
IEPE acceleration sensor in current market is often used in detection of vibration signal in station bearing, and it usually needs to install extra driver module. In this way, the cost is increase and may cause uncertain results in measurement. In addition, the sampling range of acceleration recorder in current market usually could not meet the standard to detect certain range of vibration for station bearing. In order to solve the above problem and to achieve best performance, ICP DAS has developed Accelerometer Data Logger, AR-200/AR-400.
Features: |
|
|
|
Utility: |
|
|
|

Specifications:
| Module | AR-200 | AR-400 |
| Analog Input Interface | ||
| Channels | 2 (simultaneous sampling) | 4 (simultaneous sampling) |
| ADC Resolution | 16 bit | |
| Sample rate (kHz) | 50, 100, 200 | 50, 100, 125 |
| Dynamic range | +/- 10V | |
| IEPE | 3 mA | |
| Trigger mode | Push button trigger, Schedule trigger, Analog threshold trigger, Digital input trigger and Utility Remote trigger | |
| Connector | BNC | |
| Digital Input Interface | ||
| Channels | 2, Dry Contact: Source x 1, Wet Contact: Sink or Source x 1 | |
| Dry Contact Level | Off Voltage Level: Open, On Voltage Level : Close to GND | |
| Wet Contact Level | Off Voltage Level: +4 VDC max., On Voltage Level: +10 VDC to +50 VDC | |
| Digital Output Interface | ||
| Channels | 1, Power Relay, Form A x 1 | |
| Contact Rating | AC: 125 V@0.6 A DC: 30 V@2 A, 110 V@0.6 A | |
| Ethernet Interface | ||
| Controller | 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX) | |
| Connector | RJ-45 with LED indicator | |
| SD Card Interface | ||
| Storage Media | Micro SDHC type flash – support 4 to 32 GB | |
| Recording Format | Binary | |
| LED Indicator | ||
| LED indicator | PWR LED, DAQ LED, SD LED | |
| Power | ||
| Power supply | Unregulated +10 to +30 VDC | |
| Protection | Power reverse polarity protection, Over-voltage brown-out protection | |
| Power Consumption | 4.3 W | |
| Mechanical | ||
| Installation | Wall Mount | |
| Dimensions | 197 mm x 139 mm x 57 mm (W x L x H) | |
| Environment | ||
| Operating Temp. | -25 to 75 ℃ | |
| Storage Temp. | -30 to 80 ℃ | |
| Humidity | 10 to 90% RH, non-condensing | |
Datasheet Download:
https://www.icpdas.com/web/product/download/iiot/sensor/ar/document/data_sheet/AR-200_400_datasheet_en.pdf
For more information, please refer to:
https://www.icpdas.com/en/product/AR-200
https://www.icpdas.com/en/product/AR-400
Related Product:
https://www.icpdas.com/en/product/guide+IIoT+IO_Sensor+Accelerometer__Data__Logger#913
Ordering Information:
| AR-200 CR | 2-Channels Accelerometer Data Logger device (RoHS) | |
| AR-400 CR | 4-Channels Accelerometer Data Logger device (RoHS) | |