- New Product Release: PM-4324-CPS
CANopen Multi-circuit Smart Power Meter
Mar. 19, 2019 -
-
The CANopen is a kind of network protocols evolving from CAN (Controller Area Network) bus, used on car control system in early days, and has been greatly used in various applications, such as vehicles, industrial machine, building automation, medical devices, maritime application, restaurant appliance, laboratory equipment and research. The PM-4324-CPS provides the error process mechanisms and message priority concepts. These features can improve the network reliability and transmission efficiency. Furthermore, CAN supplies the multi-master capabilities, and is especially suitable for networking “intelligent” devices as well as sensors and actuators within a system or sub-system.
The PM-4324-CPS series multi-circuit power meter monitors up to 8 three-phase circuits or 24 single-phase circuits, or any combination of single or three-phase circuits.
The PM-4324-CPS series can measure up to 24 currents via external Current Transformers (CTs). This flexibility makes the PM-4324-CPS series perfect for multi-tenant facilities such as residential projects, office buildings and shopping malls. This compact instrument is designed to easily fit into existing panelboards or be flush mounted nearby, thus eliminating the need for expensive retrofit projects or for allocating extra space for the device.
It also provides the CANopen interface for users to easily gather the real-time power consumption information in their CANopen applications. User can use CANopen PDO event time feature to response messages at regular intervals automatically. It makes the communication more efficient when collecting a lot of remote power information. In addition, the PM-4324-CPS also owns the arbitration mechanism which can avoid data collision and error detection. - Hardware Features:
- Support CANopen
- NXP TJA1042 CAN transceiver
- 3000 VDC isolation
- Operating temp. -20 °C to +70 °C
- Support 2 Power Relay Output (Form A)
- Communication Features:
- Follow CiA CANopen DS-301 specification
- CANopen Device Profile DSP-401 v2.1
- Act as NMT slave.
- Support NMT Node Guarding and Heartbeat Producer protocol.
- Support 1 SDO Server.
- Support 40 TxPDO
- PDO Mode: Event Timer, Remotely Requested, Cyclic and Acyclic SYNC
- Support baud rate 125 kbps, 250 kbps, 500 kbps and 1000 kbps
- Support up to 64 nodes on the CANopen network
- Data Update Rate :1 second
- Power Meter Features:
- 8 Three Phase Circuits or 24 Single Phase Circuits
- True RMS Power Measurements
- Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
- 2 Independent main circuit inputs for PM-4324A series
- Voltage Measurements Up to 500 V
- Current Measurements Up to 400 A with Different CT Ratio
- Total Harmonic Distortion (THD)
- Easy install with split core CT
- W Accuracy Better than 0.5% (PF=1)
-
- Related Product:PCI CANopen Master board (PISO-CPM100U) http://www.icpdas.com/root/product/solutions/industrial_communication/fieldbus/canopen/master/piso-cpm100u.html
USB CANopen Master module (I-7565-CPM) http://www.icpdas.com/root/product/solutions/industrial_communication/fieldbus/canopen/master/i-7565-cpm.html
1Port High Performance CANopen Master module (I-8123W) http://www.icpdas.com/products/Remote_IO/can_bus/i-8123w.htm - CANopen Power Meter Series:
Model Name PM-3112/3114-CPS PM-3133-CPS PM-3033-CPS PM-4324-CPS Wiring 1P2W-2CT/1P4W-4CT 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT Input Voltage 10 ~ 300 V 10 ~ 500 V Input Current CT Φ10 mm (60 A), CT Φ16 mm (100 A), CT Φ24mm (200 A) CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A); CTØ36 mm (400 A) 1A or 5A CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A); CTØ36 mm (400 A) Input Frequency 60/50 Hz kWh Accuracy 1%(PF=1) Power Relay Form A (Normal Open) x 2 - Form A (Normal Open) x 2 Data Update Rate 1 Second Operating Temperature -20 ~ +70 °C Dimensions (W x L x H) 127(L) mm x 33(W) mm x 105(H) mm 237 mm x 52 mm x 134 mm -
CAN & CANopen series Product: http://www.icpdas.com/root/product/solutions/industrial_communication/fieldbus/fieldbus_selection_guide.html
- Ordering information:
PM-3112/3114-100-CPS CR 2/4 Loops 1 Phase Compact Smart Meter/CT:2/4pcs,Φ10mm(0-60A)/English /CANopen (RoHS) PM-3112/3114-160-CPS CR 2/4 Loops 1 Phase Compact Smart Meter/CT:2/4pcs,Φ16mm(0-100A)/English /CANopen (RoHS) PM-3112/3114-240-CPS CR 2/4 Loops 1 Phase Compact Smart Meter/CT:2/4pcs,Φ24mm(0-200A)/English /CANopen (RoHS) PM-3133-100-CPS CR 3 Phase Compact Smart Meter/CT:4pcs,Φ10mm(0-60A)/English /CANopen (RoHS) PM-3133-160-CPS CR 3 Phase Compact Smart Meter/CT:4pcs,Φ16mm(0-100A)/English /CANopen (RoHS) PM-3133-240-CPS CR 3 Phase Compact Smart Meter/CT:4pcs,Φ24mm(0-200A)/English /CANopen (RoHS) PM-3033-CPS CR 3 Phase Compact Smart Meter/English /CANopen -
For more information, please visit the following website:
http://www.icpdas.com/root/product/solutions/intelligence_power_meter/pm_series/pm-4324.html