-
- home > news > products > 2015
-
End of Life Notification for PM-2133 and PM-2134 series
- EOL notification date: 2015/11/23
Phased out model: PM-2133 and PM-2134 series
Dear Partners,
ICP DAS hereby formally announces the manufacturing discontinue and End of Life (EOL) of PM-2133 and PM-2134 series.
Within the effective warranty period, ICP DAS is committed to continue providing comprehensive after-sales service and technical support.
● Reason for termination: new product migration
● Products are affected by this announcement:Modbus RTU Series CANopen SeriesCAN Bus SeriesPM-2133-100 PM-2133-100-CPS PM-2133-160 PM-2133-160-CPS PM-2133-240 PM-2133-240-CPS PM-2134-100 PM-2134-100-CPS PM-2134-100-CAN -
● Suggested replacement device: PM-2133 series → PM-3133 series
PM-2134 series → PM-3114 series
- Status: Available
- Please refer to the following table for cross reference information. -
Model Name PM-2133 SeriesPM-3133 SeriesProduct Status Phased outAvailableAC Power Measurement Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CTInput Voltage 10 ~ 500 VInput Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A)CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A)Input Frequency 50-60 HzW Accuracy Better than 1% (PF:1)Better than 0.5% (PF:1)Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), FrequencyCommunication Protocol Modbus RTUModbus RTUData Format N, 8, 1N, 8, 1Baud Rate 9600, 19200(default), 384009600, 19200(default), 38400, 115200Alarm Output Power Relay -5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC Dimension W x L x H 78 mm x 35 mm x 99 mm105 mm x 33 mm x 127 mm - For more information, please visit the link below:
PM-3133 series:
http://www.icpdas.com/root/product/solutions/intelligence_power_meter/pm_series/pm-3133.html
PM-3114 series:
http://www.icpdas.com/root/product/solutions/intelligence_power_meter/pm_series/pm-311x.html
Model Name PM-2134 SeriesPM-3114 SeriesProduct Status Phased outAvailableAC Power Measurement Wiring 1P2W, 1P4WInput Voltage 10 ~ 300 VInput Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A)CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A)Input Frequency 50-60 HzW Accuracy Better than 1% (PF:1)Better than 0.5% (PF:1)Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)Communication Protocol Modbus RTUModbus RTUData Format N, 8, 1N, 8, 1Baud Rate 9600, 19200(default), 384009600, 19200(default), 38400, 115200Alarm Output Power Relay -5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC Dimension W x L x H 78 mm x 35 mm x 99 mm105 mm x 33 mm x 127 mm