~Will be available~
 
Model: I-87016W
I-87016W
2-channel Isolated Strain Gauge Input Module
 

 

 
 
 
 
Analog Input
Input Channels 2
Input Type

+/- 15mV, +/- 50mV, +/- 100mV
+/- 500mV, +/- 1V, +/- 2.5V
-20mA ~ +20mA(No External Restistor Reguired)

Resolution 16-bit
Sampling Rate 10 Samples/ second (One-channel Mode)
2 Samples/ second (Two-channel Mode)
Accuracy +/- 0.05% of FSR
-3dB BandWidth 5.24Hz
Zero Drift +/- 0.5£gV/ ¢XC
Span Drift +/- 25 £gV/ ¢XC
Common Mode Rejection 150dB
Normal Mode Rejection 100 dB
Input Impedance 20M Ohms
Intra-module Isolation, Field to Logic 3000VDC
Excitation Voltage Output
Output Channels 1
Output Range

0 ~+10VDC

Max. Output Load current 80mA
Accuracy +/- 0.05% or Better
Drift +/- 50 ppm/ ¢XC
Output Impedance 12 Ohms
Intra-module Isolation, Field to Logic 3000VDC
Digital Output
Output Channels 2
Output Type Isolated Open Collector
Load Voltage +5VDC ~ +50VDC
Load Current 700mA/channel max.
Photo-isolation 3750Vrms
Digital Input
Input Channels 2
On Voltage Level +3.5V ~ 50V
Off Voltage Level +1V max
Input Impedance 10K Ohms, 0.66W
Event Counter Channels: 2
Max. Input Frequency: 50Hz
Min. Pulse Width 10ms
Photo-isolation 3750Vrms
LED Display
1 LED as Power/ Communication Indicator
8 LEDs as Strain Gauge/Digital Input/Digitial Output status Indicators
Power
Power Consumption Maximum : 3W
Environment
Operating Temperature -25 to 75 ¢XC
Storage Temperature -30 to 75 ¢XC
Humidity 5 to 95% RH, non-condensing
Dimensions
30mm x 102mm x 115mm(W x L x H) Detail
 
     
  back  
     
 
 
 
I-87016W-G    2-channel Isolated Strain Gauge Input Module (Gray Cover)
 
     
   
     
 
 
 
Converters    USB, RS-232, Fiber Optical to RS-485 Converters and Repeaters
Power Supply    24V DC power supply
Relay Module    External relay modules for I-7000 DO module
Learning Kit    Starter learning kit
Application Books    Application books designed with our products
Data Logger Software    User friendly data logger software (free)
 
   
  back  