~NEW~ |
|
| |
|
|
| Model: I-7015 |
Model: I-7015-G |
|
|
|
I-7015/I-7015(G)
6-channel RTD Input Module |
 |
 |
 |
|
 |
 |
|
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
| Analog Input |
| Input Channels |
6 |
| Input Type |
RTD |
| Wire connection |
2/3 wire |
| RTD Type |
Pt100, Pt1000, Ni120, Cu100, Cu1000 |
| Resolution |
16-bit |
| Sampling Rate |
12 samples/ second (Total) |
| Accuracy |
+/-0.05% |
| -3dB BandWidth |
15.7Hz |
| Zero drift |
+/-0.5£gV/¢XC |
| Span drift |
+/-20£gV/¢XC |
| Common Mode Rejection |
150 dB |
| Normal Mode Rejection |
100 dB |
| Voltage Input Impedance |
>1M Ohms |
| Open Wire Detection |
Yes |
| Individual Channel Configurable |
Yes |
| 4KV ESD Protection |
Yes, Contact for each terminal. |
| Intra-module Isolation, Field to Logic |
3000 VDC |
| Interface |
| Interface |
RS-485 |
| Format |
N, 8, 1 |
| Buad Rate |
1200 ~ 115200bps |
| LED Display |
| 1 LED as Power/ Communication indicator |
| Power |
| Input |
+10 to +30 Vdc |
| Power Consumption |
1.1W |
| Environment |
| Operating temperature |
-25 to 75¢XC |
| Storage temperature |
-40 to 85¢XC |
| Humidity |
5 to 95%, non-condensing |
| NOTE: We recommend to choose I-7015P for long distance RTD Line. |
|
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
| Type Code |
RTD Type
|
Temperature Range ¢XC
|
| 20
|
Platinum
100, £\= 0.00385
|
-100 ~ 100
|
| 21
|
Platinum
100, £\= 0.00385
|
0 ~ 100
|
| 22
|
Platinum
100, £\= 0.00385
|
0 ~ 200
|
| 23
|
Platinum
100, £\= 0.00385
|
0 ~ 600
|
| 24
|
Platinum
100, £\= 0.003916
|
-100 ~ 100
|
| 25
|
Platinum
100, £\= 0.003916
|
0 ~ 100
|
| 26
|
Platinum
100, £\= 0.003916
|
0 ~ 200
|
| 27
|
Platinum
100, £\= 0.003916
|
0 ~ 600
|
| 28
|
Nickel 120
|
-80 ~ 100
|
| 29
|
Nickel 120
|
0 ~ 100
|
| 2A
|
Platinum
1000, £\= 0.00385
|
-200 ~ 600
|
| 2B
|
Cu 100 at
0¢XC,£\= 0.00421
|
-20 ~ 150
|
| 2C |
Cu 100 at
25¢XC,£\= 0.00427
|
0 ~ 200
|
| 2D |
Cu 1000
at 0¢XC,£\= 0.00421
|
-20 ~ 150
|
| 2E
|
Platinum
100, £\= 0.00385
|
-200 ~ 200
|
| 2F
|
Platinum
100, £\= 0.003916
|
-200 ~ 200
|
| 80 |
Platinum
100, £\= 0.00385
|
-200 ~ 600
|
| 81 |
Platinum
100, £\= 0.003916
|
-200 ~ 600
|
|
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
| I-7015 |
6-channel RTD Input Module |
| I-7015 CR |
6-channel RTD Input Module (RoHS) |
|
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
|
| |
back |
|
|
|