~NEW~ |
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
The ET-7019, a web-based Ethernet I/O module, features a built-in web server, which allows configuration, I/O monitoring and I/O control by simply using a regular web browser. Besides, with the web HMI function, no more programming or HTML skills are needed; creating dynamic and attractive web pages for I/O monitoring and I/O control would be fun to engineers ever after. The ET-7019 offers easy and safe access for users from anytime and anywhere! In addition, ET-7019 also supports Modbus/TCP protocol that makes seamless integration to SCADA software.
The ET-7019 is a 16-bit, 8-channel differential analog inputs and 4-channel digital ouputs module that provides programmable input range on all analog channels(+/-15 mV, +/-50 mV, +/-100 mV, +/-500 mV, +/-1 V, +/-2.5 V, +/-5 V, +/-10 V, +/-20 mA, 0 ~ 20 mA, 4 ~ 20 mA and thermpocouples) and digital output can be set alarm output. Each analog channel is allowed to configure an individual range and has 240 Vrms high over voltage protection. more...
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
- Built-in Web Server
- Modbus/TCP Protocol
- I/O Pair Connection
- 10/100 Base-TX Ethernet
- Support Current Input, Voltage Input and Thermocouple Input
- Individual Channel Configuration
- Open Wire Detection
- Over Voltage Protection is up to 240 Vrms
- 4-channel Digital Output for Alarm Output
- Jumper Setting for Current or Voltage Input
- 2-way Isolation/ESD Protection
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
| Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis, Testing Equipment. |
|
|
| |
|
|
|
|
|
| |
back |
|
 |
|
|
| |
|
|
| |
| CPU |
| CPU |
80186 CPU (80MHz) |
| SRAM |
512K Bytes |
| Flash Memory |
512K Bytes |
| EEPROM |
16K Bytes |
| Dual Watchdog |
Yes |
| Communication |
| Ethernet Port |
10 / 100 Base-TX (With Link, Activity LED Indicator)
Automatic MDI/MDI-X |
| Analog Input |
| Input Channels |
8 Differential |
| Input Type |
+/-15 mV, +/-50 mV, +/-100 mV, +/-50 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V
Thermocouple (J, K, T, E, R, S, B, N, C, L, M, LDIN43710)
+/-20mA, 0~20mA, 4~20mA (jumper selectable) |
| Resolution |
16-bit |
| Sampling Rate |
10 samples/Sec. total |
| Accuracy |
+/-0.1 % or better |
| BandWidth |
15.7 Hz |
| Zero drift |
+/-20 £gV/¢XC |
| Span drift |
+/-25 ppm/¢XC |
| Input Impedance |
Voltage: >1 M Ohms, Current: 125 Ohms |
| Common Mode Rejection |
86 dB min. |
| Normal Mode Rejection |
100 dB |
| Open Thermocouple Detection |
Yes |
| Individual Channel Configuration |
Yes |
| Over Voltage Protection |
240 Vrms |
| ESD Protection |
4 kV Contact for each terminal, and 8KV Air for random point |
| EFT Protection |
4 kV for Power |
| Digital Output |
| Output Channels |
4 (Sink) |
| Output Type |
Isolated Open Collector |
| Max Load Current |
700 mA/ Channel |
| Load Voltage |
5 VDC ~ 50 VDC |
| 2 Way Isolation |
| Ethernet |
1500 VDC |
| AI and DO |
2500 VDC |
| Mounting |
| Din Rail Mount |
Yes |
| Wall Mount |
Yes |
| LED Display |
| L1 LED as Run indicator, L2 LED as Link/Act indicator, L3 LED as 10/100 M indicator |
| Power Requirements |
| Protection |
Power reverse polarity protection |
| Required Supply Voltage |
+10 VDC ~ 30 VDC (non-regulated) |
| Power consumption |
0.10 A/24 VDC |
| Environment |
| Operating Temperature |
-25 ¢XC ~ +75 ¢XC |
| Storage Temperature |
-30 ¢XC ~ +80 ¢XC |
| Relative Humidity |
5 to 90% RH, non-condensing |
| Dimensions |
| Dimensions(W x L x H ) |
123 mm x 72 mm x 35 mm |
|
|
|
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
| ET-7019 CR |
8-channel Analog Input with High Voltage Protection and 4-channel Isolated Output Module (RoHS) |
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
| GPSU06U-6 |
24V/0.25A output power supply |
| MDR-20-24 |
24V/1A output power supply with DIN-Rail |
| NS-205 CR |
Unmanaged 5-Port Industrial Ethernet Switch |
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
|
|