  WP-8137, WP-8437, WP-8837
WP-8147, WP-8447, WP-8847
    ISaGRAF WinPAC (Windows CE 5.0 inside)
 
   
 
     
 
Running HMI and Control Logic in the Same PAC
New!!
Trend and Gauge meter
Alarm Lists
 
     
     
 
 
 
WinPAC-8xx7 Series (WP-8137/8437/8837/8147/8447/8847) is the new generation WinCE 5.0 based ISaGRAF PAC (Programmable Automation Controller) of ICP DAS. WP-8xx7 is equipped with a PXA270 CPU (520 MHz) running Windows CE 5.0 Operating System, various connectivity including 10/100 Base-TX Dual Ethernet Ports, 2 or 4 RS-232/485 ports, 1 VGA,
1 or 2 USB ports, and 1/4/8 slots for high performance Parallel-type I/O modules (High Profile I-8K series) and Serial-type I/O modules (Hot-Swap High Profile I-87K series), etc. Memories come with 128 MB SRAM, 512 KB dual battery backup SRAM, 96 or 128 MB FLASH and 1 GB microSD. For redundant supporting: Dual Watchdog Timers, redundant power inputs, dual battery backup SRAM, dual Ethernet Ports. WinPAC Series will upgrade your control system!
 
     
     
 
 
Windows CE.NET 5.0
Hard Real-Time Capability
Fast Boot Speed
ISaGRAF Ver.3 SoftLogic Inside
Support IEC 61131-3 Standard
Support Web HMI function
Accepts max. 1 MB ISaGRAF code size
 
 
     
     
 
 
PXA270 CPU (32-bit & 520 MHz) VGA: Max. 1024*768 (for WP-8x37)
128 MB SDRAM & 128 MB Flash (for WP-8x37)   Max. 800*600 (for WP-8x47)
128 MB SDRAM & 96 MB Flash (for WP-8x47) USB: 2 (for WP-8x37)
1/4/8 I/O Slots   1 (for WP-8x47)
Dual 10/100M Ethernet Ports 64-bit Hardware Serial Number for Software Protection
2/4 Serial Ports (RS-232/485)
 
 
     
 
Top
 
     
 
 
 
Measure Humidity and Temperature Values
via DL-100TM485
2G/3G Wireless Application Database Application
 
 
Soft-GRAF: Create A Colorful HMI Redundant System with Ethernet I/O
HART Solutions Redundant System with RS-485 I/O
ISaGRAF PAC connects the Smart Meter Modbus RTU/TCP Slave Ports
Stress Monitoring Application of Constructions Modbus RTU/ASCII Master Ports
Redundant Communication System Modbus TCP/IP Master
eLogger HMI Application SMS: Short Message Service
Remote I/O Modules and Expansion module/board Multiple Web HMI - Monitor & Control Everywhere!
ZigBee Wireless Solution Motion Control
GPS Applications: ISaGRAF PAC plus I-87211W or GPS-721 Data Recorder and Data Logger
Integrate with CAN/CANopen Devices and Sensors Data Exchange: Ebus
Send Email with One Attached File Detect I-8K/I-87K I/O status
An Easy Way to Program the Fast FRnet Remote I/O Modules VIP Communication Security
   
for "Applications Supporting List" & all applications
 
 
     
 
Top
 
 
 
Spec
 
 
Models WP-8137 WP-8437 WP-8837 WP-8147 WP-8447 WP-8847
System Software  
OS Windows CE 5.0
.Net Compact Framework 3.5
Embedded Service FTP Server, Web Server
Multilanguage Support English, German, French, Spanish, Russian, Italian, Korean, Simplified Chinese, Traditional Chinese
Development Software  
ISaGRAF Software ISaGRAF Ver.3 IEC 61131-3 standard
Languages LD, ST, FBD, SFC, IL & FC
Support Soft-GRAF HMI : XP-8xx7-CE6, XP-8xx7-Atom-CE6, WP-8xx7/5xx7 and VP-2xW7/4xx7 PAC
Max. Code Size 1 MB
Scan Time 3 ~ 15 ms for normal program
15 ~ 50 ms for complex or large program
Non-ISaGRAF Options: MS eVC++ 4.0 or VS.NET 2005/2008 (VB.NET, C#.NET)
Web Service  
Web HMI PC running Internet Explorer can monitor/control PAC via Internet/modem
Security Support three levels username and password protection. (high/middle/low)
CPU Module  
CPU PXA270, 520 MHz
SDRAM 128 MB
Dual Battery Backup SRAM 512 KB; data valid up to 5 years (for retain variables)
Flash 128 MB 96 MB
EEPROM 16 KB  
Memory Expansion microSD socket with one microSD card (support up to 32 GB)
RTC (Real Time Clock) Provide second, minute, hour, date, day of week, month, year
64-bit Hardware Serial Number Yes, for Software Copy Protection
Dual Watchdog Timers Yes
Programmable LED Indicator 1
Rotary Switch Yes (0 ~ 9)
DIP Switch - Yes (8 bits) - Yes (8 bits)
VGA & Communication Ports
VGA Yes
640 x 480, 800 x 600, 1024 x 768
Yes
640 x 480, 800 x 600
Ethernet RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, LED indicators)
USB 1.1 (Host) 2 1
COM0 Internal communication with the high profile I-87K series modules in slots
COM1 RS-232 (to update firmware) (RxD, TxD and GND); non-isolated
COM2 RS-485 (Data+, Data-) with internal self-tuner ASIC;
2500 VDC isolated for WP-8137 and WP-8147; 3000 VDC isolated for other models.
COM3 - Yes - Yes
RS-232/RS-485 (RxD, TxD, CTS, RTS and GND for RS-232; Data+ and Data- for RS-485);
non-isolated
COM4 - Yes - Yes
RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated
I/O Expansion Slots  
Slot Number 1 4 8 1 4 8
Note: For High Profile I-8K and I-87K Modules Only
Mechanical  
Dimensions (W x L x H) 95 mm x 132 mm x 111 mm: WP-8137, WP-8147
231 mm x 132 mm x 111 mm: WP-8437, WP-8447
355 mm x 132 mm x 111 mm: WP-8837, WP-8847
Installation DIN-Rail or Wall Mounting
Environmental  
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Ambient Relative Humidity 10 ~ 90 % RH (non-condensing )
Power  
Input Range +10 ~ +30 VDC
Isolation 1 kV
Redundant Power Inputs Yes, with one power relay (1 A @ 24 VDC) for alarm
Capacity 8 W 25 W 25 W 8 W 30 W 30 W
Power Consumption 7.3 W 9.1 W 9.6 W 7.3 W 9.1 W 9.6 W
Protocols (some protocols need optional devices)
NET ID 1 ~ 255, User-assigned by software
Modbus TCP/IP Master Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol (FAQ-113)
Modbus RTU/ASCII Master Max. 10 ports: COM1 ~ 14 (*). (To connect to other Modbus Slave devices)
Support Multi-ports.
Modbus RTU Slave Max. 5 ports: COM1, one of COM2/3, COM4 ~ 8 (*).
(For connecting ISaGRAF, PC/HMI/OPC Server & HMI panels)
Modbus TCP/IP Slave Ethernet LAN1 & LAN2 support total up to 32 connections. (If WP-8xx7 uses 1 connection to connect each PC/HMI, it can connect up to 32 PC/HMI; If WP-8xx7 uses 2 connections to connect each PC/HMI, it can connect up to 16 PC/HMI; ...) When one Ethernet port is broken, the other one can still connect to PC/HMI.
Web HMI Protocol Ethernet Ports for connecting PC running Internet Explorer.
User-Defined Protocol COM1 ~ COM14 by Serial communication function blocks. (*)
I-7000 & I-87K RS-485
Remote I/O
One of COM2, COM3 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards and
RU-87Pn + I-87K High Profile I/O boards as Remote I/O. Max. 255 modules for one controller.
M-7000 Series Modbus I/O Max. 10 RS-485 ports (COM1 ~ 14) (*)can support M-7000 I/O. Each port can connect up to 32
M-7000 Modules.
Modbus TCP/IP I/O LAN2 supports ICP DAS Ethernet I/O: I-8KE4-MTCP and I-8KE8-MTCP. If LAN2 is broken, it will switch to LAN1 automatically to continuously work. (LAN1 & LAN2's IP are requested set in the same IP domain) (FAQ-042)
FRnet I/O Support max 8 pcs. I-8172W boards in slot 0 to 7 to connect to FRnet I/O modules, like FR-2053, FR-2057, FR-32R, FR-32P (FAQ-82 and FAQ-154) .
Each I-8172W board can connect up to 256 DI plus 256 DO channels.
Send Email Supports functions to send Email with one attached file via Ethernet port.
Ebus LAN2 to exchange data between ISaGRAF Ethernet PAC via Ethernet port.
SMS:
Short Message Service
WP-84x7/88x7's COM4/5 and WP-81x7's COM1/COM5 can link to a GSM Modem to support SMS. User can request data/control the controller by cellular phone. The controller can also send data & alarms to user's cellular phone. (*)
Optional GSM Modem: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem) or he GSM/GPRS Modem on the website: http://www.icpdas.com/products/GSM_GPRS/wireless/GSM_GPRS_modem.htm
MMICON/LCD COM4 or COM5 supports ICP DAS's MMICON. (*)
UDP Server & UDP Client :
Exchange Message & Auto-Report
LAN1 or LAN2 support UDP Server and UDP Client protocol to send/receive message to/from PC/HMI or other devices. For example, to automatically report data to InduSoft's RXTX driver.
TCP Client :
Exchange Message & Auto-Report
LAN1 or LAN2 (To send/receive message to/from PC/HMI or other devices which support TCP server protocol.)
Ex: automatically report data to InduSoft's RXTX driver, or to connect a location camera.
GPRS/SMS Support the I-8212W (2G/3G) card to receive / send a short message or to dial up to link the Internet by GPRS connection to send an email or communicate with remote stations by using "Ftp Client" (FAQ-151) and "TCP Client" / "UDP Server" / "UDP Client" (FAQ-143).
SQL Client Supports SQL Client functions to write data to (or read data from) Microsoft SQL Servers (2000 SP3, 2005, 2008)
Hot-Swap and Redundant System This redundant system has setup two "Active IP" address point to the active LAN1 and LAN2 ports always. One or more PC/HMI/SCADA can communicate with this redundant system via one of the two given active IP. So the PC/HMI/SCADA can access to the system easily without any notice about which WP-8xx7 is currently active.
Moreover, the new redundant system can integrate with the RU-87P4/87P8 Expansion Unit plus the
I-87K high-profile I/O cards to support the hot-swap application. If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system. (FAQ-093)
CAN/CANopen COM1, COM3 ~ COM14 (*)can connect one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One WP-8xx7 supports max.10 RS-232 ports to connect max.10 I-7530. (FAQ-086)
CANopen Master Support the I-8123W CANopen Master card to connect other CANopen slave devices. (FAQ-145)
HART Solutions Support I-87H17W modules in slot 0 to 7 to communicate with other HART devices.
FTP Client Support FTP client to upload files in the PAC to a remote FTP server on PC. (FAQ-151)
Soft-GRAF’s g_Alarm & g_Logger1 HMI objects support FTP client, too.  (FAQ-146)
Soft-GRAF HMI Support the Soft-GRAF HMI . User can use the Soft-GRAF Studio on the PC to design the HMI screen and then download it to the PAC to display the HMI on the PAC. (FAQ-146)
Optional I/O Functions (Refer to ISaGRAF PAC I/O Selection Guide for I/O Module list)
PWM Output High Speed PWM Module I-7088, I-8088W, I-87088W:
8-ch. PWM outputs, software support 1 Hz ~ 100 KHz (non-continuous), duty: 0.1 ~ 99.9%
DO Module as PWM 8-ch. max. 250 Hz max. For Off=2 & On=2 ms .
Output square wave: Off: 2 ~ 32766 ms, On: 2 ~ 32766 ms.
Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave)
Counter, Encoder, Frequency Parallel DI Counter 8-ch. max. For 1 controller. Counter val: 32-bit. 250 Hz max. Min. ON & OFF width must > 2 ms.
Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W.
Serial DI Counter Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit)
Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W.
Remote DI Counter All remote I-7000 & I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535
High Speed Counter I-87082W: 100 kHz max. 32 bit;
I-8084W : 250 kHz max. 32 bit
Encoder I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4M Hz for
                pulse/direction and cw/ccw input mode. (FAQ-112)
I-8084W: 250 kHz max., 4-ch encoder, can be pulse/direction, or Up/Down or A/B phase
                (Quad. mode); Not support Encoder Z-index. (FAQ-100)
Frequency I-87082W: 2-ch, 1 Hz ~ 100 kHz;
I-87088W: 8-ch, 0.1 Hz ~ 500 kHz;
I-8084W : 8-ch, 1 Hz ~ 250 kHz;
Motion Motion Control Integrate with one I-8091W (2-axis) or two I-8091W (4-axis)
*Note: COM5 ~ COM14 are resided at the expansion boards if they are plugged on slot 0 ~ 7 of WP-8xx7.
          WP-8137/8147 has no COM3 & COM4.
* ISaGRAF FAQ: http://www.icpdas.com/faq/isagraf.htm
* Recommend to use NS-205/NS-208 or RS405/RS408 Industrial Ethernet Switch.  
 
     
 
Top
 
     
 
 
WP-8137-EN CR WP-8147-EN CR 1 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English) (RoHS)
WP-8437-EN CR WP-8447-EN CR 4 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English) (RoHS)
WP-8837-EN CR WP-8847-EN CR 8 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: English) (RoHS)
WP-8137-TC CR WP-8147-TC CR 1 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese) (RoHS)
WP-8437-TC CR WP-8447-TC CR 4 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese) (RoHS)
WP-8837-TC CR WP-8847-TC CR 8 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Traditional Chinese) (RoHS)
WP-8137-SC CR WP-8147-SC CR 1 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Simplified Chinese) (RoHS)
WP-8437-SC CR WP-8447-SC CR 4 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Simplified Chinese) (RoHS)
WP-8837-SC CR WP-8847-SC CR 8 slots Ethernet WinCE 5.0 Based ISaGRAF PAC (OS: Simplified Chinese) (RoHS)
WP8-GUP-17000 Upgrade the WP-8xx1 to become WP-8xx7 (or Upgrade the WP-8xx9 to become WP-8xx6)
TPM-4100/TP-4100 10.4" (800 x 600) resistive touch panel monitor with RS-232 or USB interface
Accessories: VGA cable, RS-232 cable, USB cable, Mounting clamps and screws
 
     
     
 
     
  Click here to see more optional accessories (Software & Hardware)  
     
     
 
     
   
     
     
 