| Models |
VP-23W7 |
VP-25W7 |
| System Software |
|
| OS |
Windows CE 5.0 |
| .Net Compact Framework |
2.0 |
| Embedded Service |
FTP Server, Web Server (supports VB script, JAVA script), Embedded SQL Server |
| SDK Provided |
Dll for eVC, Dll for Visual Studio.Net 2005/2008 |
| Multilanguage Support |
English, German, French, Spanish, Russian, Italian, Simplified Chinese, Traditional Chinese |
| Development Software |
|
ISaGRAF
Software |
ISaGRAF Ver.3 |
IEC 61131-3 standard. |
| Languages |
LD, ST, FBD, SFC, IL & FC;
Support Soft-GRAF HMI: XP-8xx7-CE6, WP-8xx7 and VP-2xW7 |
| Max. Code Size |
1 MB |
| Scan Time |
3 ~ 15 ms for normal program
15 ~ 50 ms (or more)for complex or large program |
| Non-ISaGRAF |
Options: MS eVC++ 4.0 or VS .NET 2005/2008 (VB.NET, C# .NET) |
| Web Service |
|
| Web HMI |
PC running Internet Explorer can monitor/control PAC via Internet/modem |
| Security |
Support three-level username and password protection. (high/middle/low) |
| CPU Module |
|
| CPU |
PXA270 or compatible (32-bit and 520 MHz) |
| SDRAM |
128 MB |
| FLASH |
Total size |
96 MB |
| OS Image |
64 MB |
| Built-in Flash Disk |
31 MB |
| Registry |
1 MB |
| Expansion Flash Memory |
microSD socket with 2 GB microSD card (can support up to 16 GB compatible microSDHC card) |
| Dual Battery Backup SRAM |
512 KB |
| Data Retention: 5 years. |
| EEPROM |
16 KB |
| 1,000,000 erase/write cycles; Data Retention: 40 years. |
| RTC (Real Time Clock) |
Provide second, minute, hour, date, day of week, month, year |
| 64-bit Hardware Serial Number |
Yes, for Software Copy Protection |
| Dual Watchdog Timers |
Yes (0.8 second) |
| Rotary Switch |
Yes (0~9) |
| Communication Ports |
| Ethernet |
RJ-45 x 1, 10/100 Base-TX
(Auto-negotiating, LED indicators)
Please use NS-205/NS-208 Industrial Ethernet Switch. |
| USB 1.1 (host) |
1 (for USB-mouse, keyboard or USB drive) |
| COM0 |
Internal communication with the high profi le I-87K series modules in slots |
| COM2 |
RS-485 |
D2+, D2- ; self-tuner ASIC inside; |
| Isolation |
2500 VDC |
| COM3 |
RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND);
Non-Isolated; |
| MMI (Man Machine Interface) |
| LCD Monitor |
3.5" TFT (Resolution 320 x 240) |
5.7" TFT
(Resolution 640 x 480) |
| Touch Panel |
- |
Yes |
| Rubber Keypad |
24 keys |
6 keys |
| Audio |
Microphone-In and Earphone-Out |
| LED Indicators |
3 Dual-Color LEDs (PWR, RUN, LAN1, L1, L2, L3; L1~L3 For User Programmable) |
| I/O Expansion Slots |
|
| Slot Number |
3 slots (slot 0 ~ 2) |
| * For High Profile I-8K and I-87K Modules Only |
| Hot Swap |
* For High Profile I-87K Modules Only |
| Mechanical |
| Dimensions (W x L x H) |
182 mm x 158 mm x 125 mm |
| Installation |
Panel Mounting |
| Ingress Protection |
Front panel: IP65 |
| Environment |
|
| Operating Temperature |
-20 ~
+70 °C |
| Storage Temperature |
-30 ~ +80 °C |
| Ambient Relative Humidity |
10 ~ 90 % RH (non-condensing ) |
| Power |
|
| Input Range |
+10 ~ +30 VDC |
| Isolation |
1 kV |
| Capacity |
2.5 A, 5 V supply to I/O expansion slots |
| Consumption |
7.2W (0.3A @ 24 VDC) |
| Protocols (some protocols need optional devices) |
| NET ID |
From 1 ~ 255, user-assigned by software |
| Modbus TCP/IP Master |
Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol (FAQ-113) |
| Modbus RTU/ASCII Master |
Max. 10 ports: COM2, 3 and COM5 ~ 14 (*). (To connect to other Modbus Slave devices).
Support Multi-port. |
| Modbus RTU Slave |
Max. 5 Ports: one of COM2/3, COM5 ~ 8 (*).
(For connecting ISaGRAF, PC/ HMI/ OPC Server & HMI panels.) |
| Modbus TCP/IP Slave |
Yes, LAN1 and optional 2nd Ethernet Port in I-8135W support total up to 32 connections (for connecting ISaGRAF & PC / HMI). When one Ethernet port is broken, the other one can still connect to PC/HMI. |
| Web HMI |
Ethernet ports for connecting PC running Internet Explorer. |
I-7000 & I-87K
RS-485
Remote I/O |
One of COM2 or COM3 supports I-7000 I/O modules & (I-87Kn or
RU-87Pn + I-87K High Profile I/O boards) as Remote I/O. Max. 255 modules for one controller. |
| M-7000 Series Modbus I/O |
Max. 10 RS-485 ports: COM2, 3, 5 ~ 14 (*). Each port can connect up to 32 M-7000 Modules.
(with optional I-7510 repeater connected can connect up to more than 32 M-7000 Modules) |
| Modbus TCP/IP I/O |
Supports ICP DAS Ethernet I/O : I-8KE4-MTCP and I-8KE8-MTCP listed at www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-042.
If LAN1 is broken, it will switch to the 2nd Ethernet port (in optional I-8135W card) automatically to continuously work. (This need LAN1 & the 2nd Ethernet's IP are set in the same IP domain) |
| FRnet I/O |
Support max 3 pcs. I-8172W boards in slot 0 ~ 2 to connect to FRnet I/O modules, like FR-2053,
FR-2057, FR-32R, FR-32P, at www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-048. Each I-8172W board can connect up to 256 DI plus 256 DO channels. |
| Send Email |
Supports "mail_snd" and "mail_set" functions to send email with one attached file via Ethernet port. |
| Ebus |
To exchange data between ICP DAS's ISaGRAF Ethernet controllers via Ethernet port.
(LAN1 Port only) |
SMS:
Short Message Service |
COM3 or COM5 (*) can link to a GSM Modem to support SMS. User can request data/control the controller by cellular phone. The controller can also send data & alarms to user's cellular phone. Optional GSM Modems: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem) |
| User-defined Protocol |
User can write his own protocol applied at COM2, 3 and COM5 ~ COM14 (*) by Serial communication function blocks. |
| MMICON/LCD |
COM3 or COM5 (*)supports ICP DAS's MMICON. The MMICON is featured with a 240 x 64 dot LCD & a 4 x 4 Keyboard to display picture, string, integer, float, & input a char, string, integer & float. |
UDP Server & UDP Client
(Exchange Message &
Auto-Report) |
LAN1 or 2nd Ethernet port (in optional I-8135W card) support UDP Server and UDP Client protocol to send/receive message to/from PC/HMI or other devices. For example, to automatically report data to InduSoft's RXTX driver. |
TCP Client
(Exchange Message &
Auto-Report) |
LAN1 or 2nd Ethernet port (in optional I-8135W card) support TCP Client protocol to send/receive message to/from PC/HMI or other devices which support TCP Server protocol. For example, to automatically report data to InduSoft's RXTX driver, or to connect a local camera. |
| GPRS |
Support the I-8212W card to receive / send a short message or to dial up to link the Internet by GPRS connection to send an email or communicate with remote stations by using "TCP Client" or "UDP Server" or "UDP Client" . Please refer to FAQ-143. |
| SQL Client |
Supports SQL Client functions to write data to (or read data from) Microsoft SQL Servers (2000 SP3, 2005, 2008) |
New Hot-Swap and
Redundant System |
Must enable the 2nd Ethernet port in the optional I-8135W card.
This redundant system has setup two "Active IP" address point to the active VP-25W7/VP-23W7's LAN1 and 2nd Ethernet ports always. One or two or more PC/HMI/SCADA can communicate with this redundant system via one of the two given active IP.
So the PC/HMI/SCADA can access to the system easily without any notice about which VP-25W7/
VP-23W7 is currently active. Moreover, the new redundant system can integrate with the RU-87P4 and RU-87P8 expansion unit plus the I-87K high-profile I/O cards to support the hot-swap application.
If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system. Please refer to www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English) FAQ-093. |
| CAN/CANopen |
COM3 or COM5 ~ COM14 (*) can connect one I-7530 (Converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One PAC supports max.10 RS-232 ports to connect max.10 I-7530. Please refer to www.icpdas.com > FAQ > Software > ISaGRAF Ver.3 (English)
FAQ-086. |
| CANopen Master |
Support the I-8123W CANopen Master card to connect other CANopen slave devices.
Please refer to FAQ-145. |
| HART Solutions |
Support I-87H17W modules in slot 0 to 2 to communicate with other HART devices. |
| Optional I/O Functions (Refer to ISaGRAF PAC I/O Selection Guide for I/O Module list) |
| PWM Output |
|
| High Speed PWM Module |
I-7088, I-8088W, I-87088W:
8-ch. PWM outputs, software support 1 Hz ~ 100 KHz (non-continuous), duty: 0.1 ~ 99.9% |
| DO Module as PWM |
8-ch. max. 250 Hz max. For Off=2 & On=2 ms . Output square wave: Off: 2 ~ 32766 ms, On: 2 ~ 32766 ms.
Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave) |
| Counter, Encoder, Frequency |
| Parallel DI Counter |
8-ch. max. For 1 controller. Counter val: 32-bit. 250 Hz max. Min. ON & OFF width must > 2 ms. Optional DI boards:
I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W. |
| Serial DI Counter |
Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit)
Optional serial I-87K DI boards:
I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W. |
| Remote DI Counter |
All remote I-7000 & I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535 |
| High Speed Counter |
I-87082W: 100 kHz max. 32 bit;
I-8084W: 250 kHz max. 32 bit |
| Encoder |
I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4M Hz for
pulse/direction and cw/ccw input mode. (FAQ-112)
I-8084W: 250 kHz max., 4-ch encoder, can be pulse/direction, or Up/Down or A/B phase
(Quad. mode); Not support Encoder Z-index. (FAQ-100) |
| Frequency |
I-87082W: 2-ch, 1 Hz ~ 100 kHz;
I-87088W: 8-ch, 0.1 Hz ~ 500 kHz;
I-8084W: 8-ch, 1 Hz ~ 250 kHz; |
| Motion |
|
| Motion Control |
One I-8091W (2-axis) or two I-8091W (4-axis) can do motion control, only one I-8091W can do X-Y dependent motion. |
| Port |
|
| Second Ethernet |
VP-2xW7 / VP-2xW6 can add one optional I-8135W card in its slot 0 ~ 2 to expand the second Ethernet port. |
*Note: COM5 ~ COM14 are resided at the expansion boards if they are plugged on slot 0 ~ 2 of VP-2xW7.
Ex: I-8112W/8112iW/8114W/8114iW modules. |