I-87082-G

2-ch Counter/Frequency Input Module
I-87082-G
I-87082-G

Features


• 2-channel Counter/Frequency Input
• 32-bit Counter
• Isolated or Non-isolated Input
• Programmable Alarm Output
• Programmable Digital Filter
• Programmable Threshold Voltage Level
• Maximum Frequency of up to 100 kHz
• Dual Watchdog
CE FCC RoHS WEEE

Introduction

The I-87082 offers 2 high speed counter or frequency input channels and 2 digital output channels. Two types of digital input are provided, one for isolated input, and the other is for nonisolated input. The isolated input provides 3750 Vrms isolation voltage and the non-isolated input provides programmable threshold voltage level. The built-in digital filter is valid for both non-isolated and isolated input and can filter out noise where the high/low pulse width is smaller than the minimum high/low width of the digital filter. The maximum count is up to 32-bit and the maximum frequency is up to 100 kHz. The module also provides programmable alarm output with non-isolated open collectors.

Applications


• Building Automation
• Factory Automation
• Machine Automation
• Remote Maintenance
• Remote Diagnosis
• Testing Equipment

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES I-87082-G     CR DESCRIPTION2-ch Counter/Frequency Input Module (Gray Cover) (RoHS)
This combination include other products.

Similar Products

CPU Module
Watchdog Timer Yes, Module (1.6 Seconds), Communication (Programmable)
Isolation
Intra-module Isolation 3750 Vrms
LED Indicators
Status 1 x Power and Communication
8 x I/O
Digital Output
Channels 2
Sink/Source (NPN/PNP) Sink, Open Collector
Load Voltage +5 VDC ~ +30 VDC
Load Current 30 mA
Counter/Frequency/Encoder Input
Channels 2
Type Counter or Frequency
Counter Mode Up
Counter/Encoder Bits 32-bits (4,294,967,295)
Max. Counter/Frequency 100 kHz
ON Voltage Level Sensor Type:
+3.5 VDC ~ +30 VDC

Non-isolated:
0 ~ +5 VDC (Default > 2.4 VDC)
0 ~ +5 VDC (Default < 0.8 VDC)
OFF Voltage Level Sensor Type:
+1 VDC Max.

Non-isolated:
0 ~ +5 VDC (Default > 2.4 VDC)
Frequency Accuracy 1 Hz or 10 Hz (software selectable)
Programmable Alarm Mode Mode 0:
High Alarm Comparator on Counter 0 and Counter 1

Mode 1:
Two Steps High Alarm Comparator on Counter 1
Low Pass Filter 2 ~ 65000 μs
COM Ports
Baud Rate 115200 bps
Data Format N, 8, 1
Protocol DCON
Power
Consumption 0.9 W Max.
Mechanical
Dimensions (mm) 31 x 116 x 88 (W x L x H)
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +75 °C
Humidity 5 ~ 95% RH, Non-condensing