GW-2200i Series– Modbus TCP/UDP to RTU/ASCII Gateway with 2-port Ethernet Switch and Multiple Isolated RS-232/485/422 Ports
New Products
2020-09-07
GW-2212i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 1 Isolated RS-232 Port
GW-2222i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 2 Isolated RS-232 Ports
GW-2232i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 3 Isolated RS-232 Ports
GW-2215i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 1 Isolated RS-422/485 Port
GW-2225i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 2 Isolated RS-422/485 Ports
GW-2235i: Modbus/TCP to RTU/ASCII Gateway with 2-port Ethernet Switch and 3 Isolated RS-422/485 Ports
Model | tGW-700 | tGW-700i | GW-2200i |
---|---|---|---|
Shape | |||
Ethernet Port | 1 | 1 | 2-port Switch (1 IP Address) |
Signal Isolation | |||
Dimension (mm) | 95 x 52 x 27 | 95 x 52 x 27 | 126 x 97 x 33 |
Introduction:
Modbus has become a de facto standard industrial communication protocol, and is now the most commonly available means of connecting industrial electronic devices. Modbus allows for communication between many devices connected to the same RS-232/422/485 network, for example, it can connect to both temperature monitoring system and humidity monitoring system and the data from both system can be send to a computer. Modbus is often used to connect a supervisory computer to a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.The GW-2200i module is a Modbus TCP/UDP to RTU/ASCII gateway that enables a Modbus TCP/UDP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then route data over TCP/IP between two serial Modbus RTU/ASCII devices, which is useful when connecting mainframe computers, servers or other serial devices that use Modbus RTU/ASCII protocols and themselves do not have Ethernet capability. With 2 Ethernet ports, the GW-2200i allows daisy chain connection which enables flexibility in locating devices; easy installation and lower infrastructure costs.
The GW-2200i also adds 3000 VDC isolation and +/-4 kV ESD protection component that diverts the potentially damaging charge away from sensitive circuit to protects the module and equipment from the sudden and momentary electric current. The GW-2200i series have 2-port Ethernet Switch (LAN Bypass) for Daisy-Chain Wiring, it’s more convenient for deployment.
Features:
- Supports Modbus TCP/UDP master and slave
- Supports Modbus RTU/ASCII master and slave
- 10/100 Base-TX Ethernet
- 2-port Ethernet Switch (LAN Bypass) for Daisy-Chain Wiring
- 3000 VDC Isolation and +/-4 kV ESD protection per serial port (RS-232/422/485)
- Max. 32 connections (masters) per serial port
- Read-cache ensures faster Modbus TCP/UDP response
- Supports UDP responder for device discovery (UDP Search)
- Static IP or DHCP network configuration
- Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC terminal block
For more information, please visit the GW-2200i series web site.