PM-3112/PM-3114
Single-phase Smart Power Meter |
|
|
~ NEW ~ |
|
 |
 |
Model: PM-3112 |
Model: PM-3114 |
|
|
 |
- True RMS Power Measurements
- Energy Analysis for 1P2W, 1P4W
- Current Measurements Up to 200 A with Different CT Ratio
- Voltage Measurements Up to 300 V
- Clip-on CT for Easy Installation
- W Accuracy Better than 0.5% (PF=1)
- Supports Modbus RTU, Modbus TCP or CANopen Protocol
- Supports 2 Power Relay Output (Form A)
- IEC 61010-1 and EN 61010-1
|
|
|
|
 |
ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration. |
|
 |
Model |
PM-3112 |
PM-3114 |
PM-3112-MTCP |
PM-3114-MTCP |
PM-3112-CPS |
PM-3114-CPS |
AC Power Measurement |
Wiring |
1P2W-2CT |
1P4W-4CT |
1P2W-2CT |
1P4W-4CT |
1P2W-2CT |
1P4W-4CT |
Input Voltage |
10 ~ 300 V |
Input Current |
CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A) |
Input Frequency |
50/60 Hz |
W Accuracy |
Better than 0.5% (PF=1) |
Starting Current |
>0.03A (60A), >0.05A (100A), >0.09A(200A) |
Power Parameter Measurement |
True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF) |
Data Update Rate |
1 Second |
Communication |
RS-485 |
Protocol |
Modbus-RTU |
- |
- |
Baud rate |
9600,19200 (default), 38400, 115200;
DIP Switch Selectable |
- |
- |
Data format |
N,8,1 |
- |
- |
Isolation |
3000 VDC |
- |
- |
Ethernet |
Protocol |
- |
Modbus TCP |
- |
CANopen |
Protocol |
- |
- |
CAN Bus and CANopen |
Baud rate |
- |
- |
125 k (default), 250 k, 500 k, 1 M;
DIP Switch Selectable |
Alarm Output |
Power Relay |
Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC |
Power |
Input Range |
+12 ~ 48 VDC |
Power Consumption |
2 W |
Mechanical |
Casing |
Plastic (Flammability UL 94V-0) |
Dimensions (W x L x H) |
127 mm x 105 mm x 33 mm |
Module Installation |
DIN-Rail Mounting |
CT Installation |
Clip-On |
Environment |
Operating Temperature |
-20 ~ +70˚C |
Storage Temperature |
-25 ~ +80 °C |
Ambient Relative Humidity |
10% ~ 90% RH, Non-condensing |
|
|
 |
RS-485 Interface |
PM-3112-100 CR |
Modbus RTU, 2 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-160 CR |
Modbus RTU, 2 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-240 CR |
Modbus RTU, 2 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3114-100 CR |
Modbus RTU, 4 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-160 CR |
Modbus RTU, 4 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-240 CR |
Modbus RTU, 4 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 4 (RoHS) |
Ethernet Interface |
PM-3112-100-MTCP CR |
Modbus TCP, 2 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-160-MTCP CR |
Modbus TCP, 2 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-240-MTCP CR |
Modbus TCP, 2 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3114-100-MTCP CR |
Modbus TCP, 4 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-160-MTCP CR |
Modbus TCP, 4 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-240-MTCP CR |
Modbus TCP, 4 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 4 (RoHS) |
CAN bus Interface |
PM-3112-100-CPS CR |
CANopen, 2 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-160-CPS CR |
CANopen, 2 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3112-240-CPS CR |
CANopen, 2 loops single-phase Power Meter; includes 200A CT (Inside diameter 24 mm; wire lead 1.8 m) x 2 (RoHS) |
PM-3114-100-CPS CR |
CANopen, 4 loops single-phase Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-160-CPS CR |
CANopen, 4 loops single-phase Power Meter; includes 100A CT (Inside diameter 16 mm; wire lead 1.8 m) x 4 (RoHS) |
PM-3114-240-CPS CR |