FR-2046iT
16-channel Dry Contact Isolated Digital Input Module With Isolated Communication line | |
|
 |
FR-2046iT |
| ~Available soon~ |
|
|
|
|
|
 |
|
|
|
|
|
|
| |
The FR-2046iT has 16-channel isolated Dry Contact input module. The FR-2000 I/O module has an FRnet interface. The users can daisy chain several FR-2000 modules together. Via FRnet, the FR-2000 modules can extend the remote I/O control of PC, PAC and PLC easily. Further information about the networking of FR-2046iT; refer to literature related to I-7188EF, I-8172W, FRB-100/200/200U. |
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
- Built-in Wire-saving FRnet DI/DO control
- High-speed transmission reliability
- Simple synchronization mechanism
- No software overhead on protocol processing
- Supporting broadcasting (1:n data transmission)
- Duplicating output easily
- Fixed I/O scan-time and I/O synchronization
- DIN-Rail mountable
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
| Digital Input |
| Input Channel |
16 |
| Input Type |
Dry Contact, Source |
| On Voltage Level |
Open |
| Off Voltage Level |
Close to GND |
| Effective Distance |
500m Max. |
| Isolation Voltage |
3750Vrms |
| Connection |
20-Pin Removable Terminal Block |
| Interface |
| Isolation Voltage |
3000Vrms |
| 2-wire cabling |
Belden 9841 (2P twisted-pair cable),
When different cables are used, the transmission distance may be changed |
| Transfer distance |
Max. 400m for speed 250Kbps
Max. 100m for speed 1Mbps(Default) |
| LED Indicators |
Power, Communication Run, Communication Error, Terminal
resistor, Digital input |
| Transfer speed |
250Kbps and 1Mbps(Default)
DIP Switch Settings |
| Cyclic scan time |
2.88ms for speed 250Kbps
0.72ms for speed 1Mbps(Default) |
| Power |
| Input Voltage Range |
+10 ~ +30VDC (Non-isolation) |
| Power consumption |
2.4W Max |
| Protection |
Power reverse polarity protection |
| Frame Ground for EMS Protection |
Yes |
| Connection |
5-Pin Removable Terminal Block |
| EMS Protection |
| ESD |
4KV for power liner, Communication line and each channel |
| EFT |
1KV for power liner |
| Surge |
0.5KV for power liner |
| Case |
| Case |
Plastic |
| Flammability |
UL 94V-0 materials |
| Dimensions |
32.5mm x 110mm x 102mm (W x H x D) |
| Installation |
DIN-Rail |
| Environmental |
| Operating Temperature |
-25 ¢XC~ +75¢XC |
| Storage Temperature |
-30 ~ +85¢XC |
| Ambient Relative Humidity |
10 to 90% RH, non-condensing |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
| FR-2046iT |
16-channel Dry Contact Isolated Digital Input Module With Isolated Communication line |
|
|
| |
|
|
|
|
|
| |
|
|
| |
|
|
| |
| GPSU06U-6 |
24V/0.25A Power Supply, (No-mounting) |
| DIN-KA52F |
24V/1A Power Supply, (With DIN-Rail mounting) |
|
|
| |
|
|
|
|
|
| |
|
|
|
|