Function | tGW-700 | tGW-700i | tGW-700-T | tGW-700i-T | GW-2200i |
---|---|---|---|---|---|
Shape | ![]() |
![]() |
![]() |
||
Ethernet Port | 1 | 1 | 1 | 1 | 2-port Switch (1 IP Address) |
Isolation | ![]() |
![]() |
![]() |
![]() |
![]() |
PoE | ![]() |
![]() |
![]() |
![]() |
Only for ETH1 |
DC Power Input | DC Jack | Terminal Block | |||
Virtual COM | ![]() |
![]() |
![]() |
![]() |
![]() |
Modbus Gateway | ![]() |
![]() |
![]() |
![]() |
![]() |
Multi-client | ![]() |
![]() |
![]() |
![]() |
![]() |
Form Factor | Tiny Size | Tiny Size | Tiny Size | Tiny Size | Slim Type |
Dimension (mm) | 95 x 52 x 27 | 95 x 52 x 27 | 95 x 52 x 27 | 95 x 52 x 27 | 126 x 97 x 33 |
The tGW-700/GW-2200i module off ers true IEEE 802.3afcompliant (classification, Class 1) Power over Ethernet (PoE) functionality using a standard category 5 Ethernet cable to receive power from a PoE switch such as the NS-205PSE. If there is no PoE switch on site, the module will also accept power input from a DC adapter. The tGW-700/GW-2200i module is designed for ultra-low power consumption, reducing hidden costs from increasing fuel and electricity prices,especially when you have a large number of modules installed. Reducing the amount of electricity consumed by choosing energy-effi cient equipment can have a positive impact on maintaining a green environment.
Based on an amazing tiny form-factor, the tGW-700/GW-2200i achieves maximum space savings that allows it to be easily installed anywhere, even directly embedded into a machine. It also supports automatic RS-485 direction control when sending and receiving data, thereby improving the stability of the RS-485 communication.

Tiny Gateway Application

|
|||||||
tGW-700 Series (Tiny Modbus/TCP to RTU/ASCII Gateway with PoE and DC jack): Includes DC connector to 2-wire power cable, 0.3 M
|
|||||||
Model (Non-Isolated) | Model (Isolated) | RS-232 | RS-422 | RS-485 | COM1 | COM2 | COM3 |
---|---|---|---|---|---|---|---|
tGW-712 | tGW-712i | 1 | - | - | 3-wire RS-232 | - | - |
tGW-722 | tGW-722i | 2 | - | - | 3-wire RS-232 | 3-wire RS-232 | - |
tGW-732 | tGW-732i | 3 | - | - | 3-wire RS-232 | 3-wire RS-232 | 3-wire RS-232 |
tGW-715 | tGW-715i | - | 1 | 2-wire RS-485 4-wire RS-422 |
- | - | |
tGW-725 | tGW-725i | - | - | 2 | 2-wire RS-485 | 2-wire RS-485 | - |
tGW-735 | tGW-735i | - | - | 3 | 2-wire RS-485 | 2-wire RS-485 | 2-wire RS-485 |
tGW-718 | tGW-718i | 1 | 3-wire RS-232 | - | - | ||
2-wire RS-485 4-wire RS-422 |
|||||||
- | tGW-718i-D | 1 | 5-wire RS-232 | - | - | ||
2-wire RS-485 4-wire RS-422 |
|||||||
tGW-724 | tGW-724i | 1 | - | 1 | 2-wire RS-485 | 5-wire RS-232 | - |
tGW-734 | tGW-734i | 2 | - | 1 | 2-wire RS-485 | 3-wire RS-232 | 3-wire RS-232 |
|
|||||||
tGW-700-T Series (Tiny Modbus/TCP to RTU/ASCII Gateway with DC Terminal Block):
|
|||||||
Model (Non-Isolated) | Model (Isolated) | RS-232 | RS-422 | RS-485 | COM1 | COM2 | COM3 |
---|---|---|---|---|---|---|---|
tGW-715-T | tGW-715i-T | - | 1 | 2-wire RS-485 4-wire RS-422 |
- | - | |
tGW-718-T | tGW-718i-T | 1 | 3-wire RS-232 | - | - | ||
2-wire RS-485 4-wire RS-422 |
|||||||
Note: The tGW-700-T series don't support PoE power supply. |
|
|||||||
GW-2200 Series(Modbus/TCP to RTU/ASCII Gateway with PoE and Terminal Block)
|
|||||||
Model (Isolated) | Ethernet | RS-232 | RS-422 | RS-485 | COM1 | COM2 | COM3 |
---|---|---|---|---|---|---|---|
GW-2212i | 2-Port Switch, 10/100M |
1 | - | - | 5-wire RS-232 | - | - |
GW-2222i | 2 | - | - | 5-wire RS-232 | - | ||
GW-2232i | 3 | - | - | 5-wire RS232 | |||
GW-2215i | - | 1 | 2-wire RS-485 4-wire RS-422 |
- | - | ||
GW-2225i | - | 2 | 2-wire RS-485 4-wire RS-422 |
- | |||
GW-2235i | - | 3 | 2-wire RS-485 4-wire RS-422 |
||||