WISE-7102
Introduction
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
WISE-7102 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7102 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
This multi-function module WISE-7102 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 3-channels analog inputs, 6-channels digital inputs and 3-channels Power Relay outputs. Each analog input channel provides 240 Vrms high over voltage protection.
WISE-7102 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7102 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
This multi-function module WISE-7102 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 3-channels analog inputs, 6-channels digital inputs and 3-channels Power Relay outputs. Each analog input channel provides 240 Vrms high over voltage protection.

Applications
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.
More detailed application case, you can find on here.
More detailed application case, you can find on here.
Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
This combination include other products.
Similar Products
Software | |
---|---|
Protocol | • Modbus TCP • CGI Command (Sending) |
Function | • Web Interface for Configuration • IF-THEN-ELSE Logic operation (36 rule supported) • I/O channel monitoring and control • Timer operation (12 set supported) • Internal Register operation (48 set supported) • Recipe operation (12 set supported) • Advanced P2P (8 set supported) • non-SSL Email sending function |
CPU Module | |
---|---|
CPU | 16-bit CPU (80 MHz) |
Isolation | |
---|---|
Intra-module Isolation | 2500 VDC |
EMS Protection | |
---|---|
EFT (IEC 61000-4-4) | ±4 kV for Power Line |
ESD (IEC 61000-4-2) | ±4 kV Contact for each terminal and ±8 kV Air for random point |
Surge (IEC 61000-4-5) | ±0.5 kV for Power Line |
LED Indicators | |
---|---|
Status | 1 x PoE Power 1 x System Running 1 x Ethernet Link/Act 1 x Ethernet 10/100M Speed |
Analog Input | |
---|---|
Channels | 3 (Differential) |
Type | ±150mv, ±500mv, ±1 V, ±5 V, ±10 V ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA (Jumper Selectable) |
Resolution | 16-bit |
Accuracy | ±0.1% |
Sampling Rate | 10 Sample/Sec. (Total) |
Input Impedance | Voltage: 2 MΩ Current: 125 Ω |
Common Mode Rejection | 86 dB Min. |
Normal Mode Rejection | 100 dB |
Overvoltage Protection | 240 Vrms |
Overcurrent Protection | Yes, 50 mA max. at 110 VDC/VAC max. |
Individual Channel Configuration | Yes |
Open Wire Detection | Yes, for 4 ~ 20 mA only |
Zero Drift | ±20 μV/°C |
Span Drift | ±25 ppm/°C |
Digital Input/Counter | |
---|---|
Channels | 6 |
Type | Wet Contact |
Sink/Source (NPN/PNP) | Sink/Source |
ON Voltage Level | +10 VDC ~ +50 VDC |
OFF Voltage Level | +4 VDC Max. |
Max. Counts | 16-bit (65535) |
Frequency | 50 Hz |
Min. Pulse Width | 10 ms |
Input Impedance | 10 KΩ, 0.5W |
Overvoltage Protection | +70 VDC |
Relay Output | |
---|---|
Channels | 3 |
Type | Power Relay, Form A (SPST N.O.) |
Contact Rating | Operating Voltage Range: 250 VAC/30 VDC Max Load Current: 5.0A/channel at 25°C Intra-module Isolation, Field to Logic: 3750 VDC |
Operate Time | 6 ms (Typical) |
Release Time | 3 ms (Typical) |
Electrical Endurance | VDE: 5 A @ 250 VAC 30,000 ops. (10 ops./minute) at 75°C 5 A @ 30 VDC 70,000 ops. (10 ops./minute) at 75°C UL: 5 A @ 250 VAC/30 VDC 6,000 ops. 3 A @ 250 VAC/30 VDC 100,000 ops. |
Mechanical Endurance | 20,000,000 ops. at no load (300 ops./minute) |
Ethernet | |
---|---|
Ports | RJ-45 x 1, 10/100 Base-TX and automatic MDI/MDI-X |
PoE | Yes |
Power | |
---|---|
Reverse Polarity Protection | Yes |
Input Range | 12 ~ 48 VDC |
Consumption | 3.4 W |
Powered from PoE | Yes, IEEE 802.3af, Class 1 |
Powered from Terminal Block | Yes, 12 ~ 48 VDC |
Mechanical | |
---|---|
Dimensions (mm) | 72 x 123 x 35 (W x L x H) |
Installation | DIN-Rail Mounting/Wall Mounting |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ +80 °C |
Humidity | 10 ~ 90% RH, Non-condensing |