PM-4324D-100P-CPS

Multi-circuit Smart Power Meter with LCD Display
PM-4324D-100P-CPS
PM-4324D-100P-CPS

Features

• Bi-directional Energy
• 8 Three Phase Circuits or 24 Single Phase Circuits
• True RMS Power Measurements
• Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
• Current Measurements Up to 60 A with Different CT Ratio
• Voltage Measurements Up to 600 V
• Easy install with split core CT
• W Accuracy Better than 0.5% (PF=1)
• Total Harmonic Distortion (THD)
• LCD Display
• 2/3-wire DS18B20 Wire Connection
• Support CANopen Protocol
• Support 2 Power Relay Output (Form A)
RoHS WEEE

Introduction

The PM-4324D series multi-circuit power meter monitors up to 8 three-phase circuits or 24 single-phase circuits, or any combination of single or three-phase circuits. The PM-4324D series can measure up to 24 currents via external Current Transformers (CTs). This flexibility makes the PM-4324D series perfect for multi-tenant facilities such as residential projects, office buildings and shopping malls. This compact instrument is designed to easily fit into existing panelboards or be flush mounted nearby, thus eliminating the need for expensive retrofit projects or for allocating extra space for the device. The digital temperature sensor function that provides one port for 2- or 3 wire DS18B20 digital temperature sensor input. This meter has LCD display shows power.

Applications


• Generator monitoring
• Switchgear distribution systems
• Energy Management
• Power quality analysis

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES PM-4324D-100P-CPS     CR DESCRIPTIONCANopen, Multi-Circuit Power Meter; includes 60A CT (Inside diameter 10 mm; wire lead 4 m) x 24 (RoHS)
This combination include other products.

Similar Products

AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Loops Multi-circuit
Input Voltage 10 ~ 600 V
Input Current CTØ10 mm (0.05 A ~ 60 A)
Input Frequency 50/60 Hz
W Accuracy Better than 0.5% (PF=1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh),Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate 1 Second
LCD Display Yes
CT
Includes CTs 24
Type Clip
Max. Current 60 A
Inside Diameter 10 mm
Leading Cable 4 mm
CANopen
Baud Rate 125 k (default), 250 k, 500 k, 1 M; DIP Switch Selectable
Isolation 3000 VDC
Protocol CANopen
Power
Input Range +85 ~ +264 VAC (277 VAC available)
Consumption 6 W
Alarm Output Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63 Hz), 5 A @ 30 VDC
Mechanical
Casing Metal
Dimensions (mm) 237 x 57 x 134 (W x L x H)
Installation DIN-Rail & wall mounting
Environment
Operating Temperature -20 ~ +70 °C
Storage Temperature -25 ~ +80 °C
Humidity 10 ~ 90% RH, Non-condensing