GW-7238D-G

J1939 to Modbus TCP Server / RTU Slave Gateway
GW-7238D-G
GW-7238D-G
GW-7238D-G
GW-7238D-G

Features

  • Built-in jumper to select 120 ohm terminal resistor
  • Watchdog inside
  • Transmission and reception of all types of J1939 messages, including PDU1, PDU2, broadcast and destination specific
  • J1939 Transport Protocol for transmission and reception of large messages (9 - 1785 bytes)
  • Supports BAM of Connection Management Message
  • Network addresses management
  • Supports Modbus TCP server / RTU slave protoco
CE FCC RoHS WEEE

Introduction

The GW-7238D is a gateway that provides conversion between J1939 and Modbus TCP/RTU protocol. For J1939 network, the GW-7238D supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. For Modbus TCP/RTU network, the GW-7238D is a Modbus TCP server / RTU slave to reply the request from Modbus TCP client / RTU master. Utility software is provided for users to configure J1939 and Modbus TCP/RTU setting in the GW-7238D. The application fields can be diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7238D

Applications

  • Diesel power-train applications
  • Diesel power-train applications
  • In-Vehicle networks for trucks and buses
  • Truck-Trailer connections
  • On Board Diagnostics
  • Vehicle Automation

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES GW-7238D-G     CR DESCRIPTION J1939 to Modbus TCP Server / RTU Slave Gateway included CA-0910 cable (RoHS)
This combination include other products.

Similar Products

CPU Module
CPU 80186, 80 MHz or compatible
LED Indicators
Status PWR / J1939 / MODBUS / ERR
Ethernet
Protocol RJ-45 with LED indicator / Modbus TCP
COM Ports
Ports 1 x RS-232
1 x RS-485 (Self-turner inside)
Baud Rate 9600, 19200, 38400, 57600, 115200
Protocol Modbus RTU
J1939
Controller NXP SJA1000T with 16 MHz clock
Ports 1
Baud Rate 250 k
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Jumper for 120 Ω terminal resistor
Specification ISO-11898-2, CAN 2.0A and CAN 2.0B
Power
Consumption 2 W
Mechanical
Dimensions (mm) 122 x 72 x 33 (L x W x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing
  • Provide Modbus network configuration interface
  • Provide J1939 network configuration interface – Network Address / Device Name, etc
  • Provide J1939 Input / Output configuration interface
  • Provide Modbus monitoring interface

GW-7238D Utility Main Screen

Modbus monitoring table

Comparison Table

ICP DAS Fieldbus Gateways Comparison Table:
Model Support Protocol Comm. Interface
GW-7228 J1939 Modbus RTU lave RS-232
RS-422
RS-485
GW-7238D J1939 Modbus TCP Server
RTU Slave
RS-232
RS-485
Ethernet
GW-7433D CANopen Master Modbus TCP server
RTU Slave
RS-232
RS-485
Ethernet
I-7231D CANopen Slave DCON Master RS-232
RS-485
I-7232D CANopen Slave Modbus RTU Master RS-232
RS-485
I-7241D DeviceNet Slave DCON Master RS-232
RS-485
I-7242D DeviceNet Slave Modbus RTU Master RS-232
RS-485
GW-7243D DeviceNet Slave Modbus TCP/RTU/
ASCII Master
RS-232
RS-485
Ethernet
GW-7434D DeviceNet Master Modbus
TCP Server
RTU Slave
RS-232
RS-485
Ethernet
GW-7552 PROFIBUS DP-V0 Slave Modbus RTU/
ASCII Master/Slave
RS-232
RS-422
RS-485
GW-7553 PROFIBUS DP-V0 Slave Modbus TCP/RTU/
ASCII Master/Slave
RS-232
Ethernet
GW-7557 PROFIBUS DP-V0 Slave HART Master RS-232
HART-710 HART Master Modbus RTU/ASCII Slave RS-232
RS-422
RS-485
GW-5492 BACnet/IP Server Modbus RTU Master RS-232
RS-485
Ethernet
GW-5493 BACnet/IP Server Modbus TCP Client RS-232