GW-7228-G
Introduction
The GW-7228 is a solution that provides a protocol conversion between J1939 and Modbus RTU. For J1939 network, the GW-7228 supports PDU1, PDU2, broadcast and destination specific type of J1939 messages. From the view of Modbus RTU network, the GW-7228 is a Modbus RTU slave to reply the request from Modbus RTU master. We provide Utility software for users to configure the parameters of J1939 / Modbus RTU of the GW-7228. The application fields can be Diesel power-train applications, In-Vehicle networks for trucks and buses, etc.
The following figure shows the application architecture for the GW-7228

Applications
- Diesel power-train applications
- In-Vehicle networks for trucks and buses
- Truck-Trailer connections
- Fleet management systems
- On Board Diagnostics
- Vehicle Automation

Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
This combination include other products.
Similar Products
LED Indicators | |
---|---|
Status | PWR / J1939 / MODBUS |
COM Ports | |
---|---|
Ports | 1 x RS-232(TXD, RXD, GND) 1 x RS-422(Tx+, Tx-, Rx+, Rx-) 1 x RS-485(D+, D-) |
Baud Rate | 9600, 19200, 38400, 57600, 115200 |
Protocol | Modbus RTU |
J1939 | |
---|---|
Ports | 1 |
Baud Rate | 250k |
Isolation | 3000 VDC power protection on CAN side, 2500Vrms photo-couple isolation on CAN bus |
Terminal Resistor | Jumper for 120 Ω terminal resistor |
Specification | ISO-11898-2, CAN 2.0A and CAN 2.0B |
Pin Assignment | C.I.A. DS-102 (CAN_H=7, CAN_L=2) |
Power | |
---|---|
Consumption | 1.5 W |
Mechanical | |
---|---|
Dimensions (mm) | 108 x 72 x 35 (H x W x L) |
Installation | DIN-Rail |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 ℃ |
Storage Temperature | -30 ~ +80 ℃ |
Humidity | 10 ~ 90% RH, Non-condensing |
- Provide Modbus network configuration interface
- Provide J1939 network configuration interface – Network Address / Device Name…
- Provide J1939 Input / Output configuration interface

Comparison Table
ICP DAS Fieldbus Gateways Comparison Table:
|
|||
Model | Support Protocol | Comm. Interface | |
---|---|---|---|
GW-7228 | J1939 | Modbus RTU Slave | RS-232 RS-422 RS-485 |
GW-7433D | CANopen Master | Modbus TCP server/RTU Slave | RS-232 RS-485 Ethernet |
I-7231D | CANopen Slave | DCON Master | RS-232 RS-485 |
I-7232D | CANopen Slave | Modbus RTU Master | RS-232 RS-485 |
I-7241D | DeviceNet Slave | DCON Master | RS-232 RS-485 |
I-7242D | DeviceNet Slave | Modbus RTU Master | RS-232 RS-485 |
I-7243D | DeviceNet Master | Modbus TCP server | Ethernet |
GW-7243D | DeviceNet Slave | Modbus TCP/RTU/ASCII Master | RS-232 RS-485 Ethernet |
GW-7552 | PROFIBUS DP-V0 Slave | Modbus RTU/ASCII Master/Slave |
RS-232 RS-422 RS-485 |
GW-7553 | PROFIBUS DP-V0 Slave | Modbus TCP/RTU/ASCII Master/Slave | RS-232 Ethernet |