DN-848VI-80V
Introduction
The DN-800V series are voltage input attenuator. The maximum input range is from ±80 V to +/- 600 V and can be attenuated to ±10 V. The "I" version provide 3000 VDC intra-modules isolation and 3000 VDC channel to channel isolation to avoid the noise interference from inputs to outputs or channel to channel. It can be used with the analog input modules such as I-7017 and I-87017 etc. to measure the high voltage.
Applications
Ordering Information
PRODUCT SERIES | DESCRIPTION | QNT. | INQUIRY |
---|---|---|---|
This combination include other products.
Similar Products
EMS Protection | |
---|---|
ESD (IEC 61000-4-2) | ±4 kV contact for power line, input and output channels, ±8 kV air for random point |
Surge (IEC 61000-4-5) | ±3 kV for power liner |
Analog Input | |
---|---|
Channels | 8 |
Type | AC/DC Voltage |
Range | ±80 Vpp |
Accuracy | 1% of FSR |
Bandwidth | 30 KHz |
Input Impedance | >1 MΩ |
Channel-to-Channel Isolation | 3000 VDC |
Intra-module Isolation | 3000 VDC |
Analog Output | |
---|---|
Channels | 8 |
Type | AC/DC Voltage |
Range | ±10 Vpp |
Power | |
---|---|
Input Range | +10 ~ +30 VDC |
Consumption | 9.2 W |
Mechanical | |
---|---|
Casing | Plastic |
Dimensions (mm) | 174 x 122 x 33 (W x L x D) |
Installation | DIN-Rail Mounting |
Environment | |
---|---|
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ +75 °C |
Humidity | 10 ~ 90% RH, Non-condensing |