Features

  • 10-channel, 16-bit resolution thermocouple input DeviceNet slave general-purpose I/O device
  • Comply with DeviceNet specification Volume I, Release 2.0 & Volume II, Release 2.0, Errata 5
  • Group 2 Only Server (non UCMM-capable)
  • Connection supported:
    • 1 connection for Explicit Messaging
    • 1 connection for Polled I/O
    • 1 connection for Bit-Strobe I/O connection
  • Support DeviceNet Heartbeat and Shutdown message
  • Set the DeviceNet device station number and baud rate through the rotary switch
  • Provide EDS file for DeviceNet master interface
  • LED indicators for power and DeviceNet status
CE UKCA RoHS WEEE

Introduction

DeviceNet is one kind of the network protocols based on the CAN bus and mainly used for the embedded network of the machine control, such as industrial machine control , aircraft engines monitoring, factory automation, medical equipments control, remote data acquisition, environmental monitoring, and packaging machines control, etc. The CAN-2019D/S2 follows DeviceNet specification Volume I/II, Release 2.0. User can access the thermocouple input status and set the configuration via DeviceNet EDS file. CAN-2019D/S2 has 10-channel thermocouple input and it can be used to various applications. By the DeviceNet masters of ICP DAS, you can quickly build a DeviceNet network to approach your requirements. For more information about the DeviceNet master interfaces and other DeviceNet products, please refer to the following web site.

Applications

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES CAN-2019D/S2     CR DESCRIPTIONDeviceNet Slave Module of 10-channel Universal AI (RoHS)
Includes a DN-1822 daughter board, a 1.8m Cable
This combination include other products.

Similar Products

LED Indicators
Status 1 x Power
2 x DeviceNet status
Analog Input
Channels 10 (Differential)
Sensor Type +/- 15mV, +/- 50mV, +/- 100mV, +/- 500mV, +/- 1V, +/- 2.5V, +/- 5V, +/- 10V
+/-20mA,(Requires Optional External 125 Ohm Resistor)
Thermocouple (J, K, T, E, R, S, B, N, C)
Resolution 16-bit
Accuracy +/-0.1% FSR
Sampling Rate 10 Samples/Sec. (Total)
Input Impedance >400 kΩ
Common Mode Rejection 86 dB Min.
Normal Mode Rejection 100 dB
Overvoltage Protection 240 Vrms
Individual Channel Configuration Yes
Open Wire Detection Yes
Zero Drift +/- 10 μV/ °C
Span Drift +/-25 ppm/ °C
Intra-module Isolation 3000 VDC
DeviceNet
Ports 1
Connection Supported 1 connection for Explicit Messaging
1 connection for Polled I/O
1 connection for Bit-Strobe I/O
Baud Rate 125 kbps, 250 kbps, 500 kbps
Terminal Resistor Switch for 120 Ω terminal resistor
Specification Volume I, Release 2.0 & Volume II, Release 2.0, Errata5
Node ID 0 ~ 63
Shutdown Message Yes
Heartbeat Message Yes
Subscribe Group 2 Only Server
Power
Input Range +10 VDC ~ +30 VDC
Consumption 1.5 W
Mechanical
Dimensions (mm) 33 x 99 x 78 ( W x L x H )
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing