PM-2133 and PM-2134 series

EOL 2015-12-07

EOL notification date: 2015/11/23
Phased out model: PM-2133 and PM-2134 series

Dear Partners,
ICP DAS hereby formally announces the manufacturing discontinue and End of Life (EOL) of PM-2133 and PM-2134 series.

Within the effective warranty period, ICP DAS is committed to continue providing comprehensive after-sales service and technical support.
  • Reason for termination: new product migration
  • Products are affected by this announcement:
Modbus RTU Series CANopen Series CAN Bus Series
PM-2133-100 PM-2133-100-CPS  
PM-2133-160 PM-2133-160-CPS
PM-2133-240 PM-2133-240-CPS
PM-2134-100 PM-2134-100-CPS PM-2134-100-CAN


  • Suggested replacement device:
    PM-2133 series → PM-3133 series
    PM-2134 series → PM-3114 series
- Status: Available
- Please refer to the following table for cross reference information.
 
Model Name PM-2133 Series PM-3133 Series
Product Status Phased out Available
AC Power Measurement
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Input Voltage 10 ~ 500 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A) CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A); CTØ36 mm (300 A)
Input Frequency 50-60 Hz
W Accuracy Better than 1% (PF:1) Better than 0.5% (PF:1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Communication
Protocol Modbus RTU Modbus RTU
Data Format N, 8, 1 N, 8, 1
Baud Rate 9600, 19200(default), 38400 9600, 19200(default), 38400, 115200
Alarm Output
Power Relay - 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Dimension
W x L x H 78 mm x 35 mm x 99 mm 105 mm x 33 mm x 127 mm


Model Name PM-2134 Series PM-3134 Series
Product Status Phased out Available
AC Power Measurement
Wiring 1P2W, 1P4W
Input Voltage 10 ~ 300 V
Input Current CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A) CTØ10 mm (60 A); CTØ16 mm (100 A); CTØ24 mm (200 A)
Input Frequency 50-60 Hz
W Accuracy Better than 1% (PF:1) Better than 0.5% (PF:1)
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Communication
Protocol Modbus RTU Modbus RTU
Data Format N, 8, 1 N, 8, 1
Baud Rate 9600, 19200(default), 38400 9600, 19200(default), 38400, 115200
Alarm Output
Power Relay - 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
Dimension
W x L x H 78 mm x 35 mm x 99 mm 105 mm x 33 mm x 127 mm


For more information, please visit the link below:
https://www.icpdas.com/en/product/guide+Energy__Management+Power__Meter+Single-phase__Smart__Power__Meter#487