ZB-2000 series
EOL
2013-08-23
ICP DAS hereby formally unveils the End of Life (EOL) notification that all the ZB-2000 series will be phased out of production at December 31, 2013. The suggested replacement devices are ZT-2000 series.
EOL Reason: the main component, ZigBee module, is stopped production.
Replacement Device: ZT-2000 series (Available now)
Description:
The ZT-2000 series provides most of all functions of the ZB-2000 series, but the ZT-2000 series and the ZB-2000 series use different low level communication protocols. That is to say that the ZT-2000 series can’t communicate with all of the ZB-2000 series. The differences are listed in the following table.
Product series | ZB-2000 | ZB-2000-T | ZB-2000-P | ZB-2000-PA | ZT-2000 |
---|---|---|---|---|---|
Transmission power | 9 dBm | 4 dBm | 22 dBm | 11 dBm (CE/FCC) (Max. 19 dBm) | |
Antenna Gain | 3 dBi | 5 dBi | |||
Transmission range (LOS) | 100 m | 700 m (Typical) 1 km (Max.) |
|||
Certification | No | CE/FCC, FCC ID | No | CE/FCC, FCC ID | |
Max. Nodes in one network | 61 | 255 | 61 | 255 | 256 |
Protocol | Private | ZigBee 2007 Pro | |||
Routing Mechanism | Automatic/Specific | Automatic | |||
RSSI Indicator | No | Yes | |||
Configuration | Complex | Simple | |||
Support ZB-100R or ZB-100T | No | Yes | No | Yes | No |
Due to the high compatibility of the product functions, most of applications can directly use the ZT-2000 series to instead of ZB-2000 series without any modification. In order to reduce the impact of original applications, we will still supply the ZB-2000 series until the end of this year, and also do our best to help users to apply the ZT-2000 series in their original system. By means of more reliable and more flexible features, the ZT-2000 series brings you better user experience of the ZigBee applications. For more information about the ZT-2000 series, please visit the following web site: