I-7018BL/I-7018P
8-channel Analog Input Module |
|
|
|
|
 |
 |
Model: I-7018BL |
Model: I-7018P |
|
|
 |
- I-7018BL
- Open Thermocouple Detection
- I-7018P
- Additional Thermocouple Types, L and M
- 8-channel Differential or 6-channel Differential and 2-channel Single-ended Analog Input
- Current, Voltage or Thermocouple Input
- High Resolution: 16-bit
- 3000 VDC Intra-module Isolation
- Dual Watchdog
- RoHS Compliant
- Wide Operating Temperature Range: -25 to +75°C
|
|
|
|
 |
The I-7018P is an Analog Input module that features current and voltage input, as well as thermocouple input. The I-7018BL is a thermocouple input module. Both of the modules provide 8-channel differential or 6-channel differential and 2-channel single ended input that can be selected via a jumper, and all channels can be configured for the same input type. Note that an optional external 125 Ω resistor is required for current input. The modules also feature 3000 VDC intra-module isolation as well as ±35 VDC overvoltage protection. The I-7018BL provides thermocouple open wire detection and the I-7018P provides support for two additional thermocouple types, L and M. |
|
 |
- Building Automation
- Factory Automation
- Machine Automation
- Remote Maintenance
- Remote Diagnosis
- Testing Equipment
|
|
 |
Models |
I-7018BL |
I-7018P |
Analog Input |
Channels |
Differential and Single-ended, or Differential |
Wiring |
Differential |
Sensor Types |
Thermocouple |
J, K, T, E, R, S, B, N, C |
J, K, T, E, R, S, B, N, C, L, M |
Voltage |
- |
±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V |
Current |
- |
±20 mA (requires an optional external 125 Ω resistor) |
Resolution |
16-bit |
Accuracy |
0.15% of FSR |
0.1% of FSR |
Sampling Rate |
10 Hz |
Input Impedance |
> 400 kΩ |
Common Voltage Protection |
±15 VDC |
Individual Channel Configuration |
- |
Overvoltage Protection |
±35 VDC |
±80 VDC |
Open Wire Detection
(for thermocouple only) |
Yes |
- |
Temperature Output Consistency |
- |
Stable Temperature Output in the Field |
- |
|
Note: For highly-accurate thermocouple measurement, ICP DAS recommends selecting the I-7018Z/I-7019Z module,which features automatic cold-junction compensation for each channel, ensuring consistent and stable temperature output. |
|
 |
Models |
I-7018BL |
I-7018P |
Communication |
Interface |
RS-485 |
Bias Resistor |
No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) |
Format |
(N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) |
Baud Rate |
1200 to 115200 bps |
Protocol |
DCON |
Dual Watchdog |
Yes, Module (1.6 Seconds), Communication (Programmable) |
LED Indicator/Display |
System LED Indicator |
Yes, 1 as Power/Communication Indicator |
I/O LED Indicator |
- |
7-Segment LED Display |
- |
Isolation |
Intra-Module Isolation, Field-to-Logic |
3000 VDC |
EMS Protection |
ESD (IEC 61000-4-2) |
±2 kV Contact for each Terminal |
EFT (IEC 61000-4-4) |
±4 kV to Power |
Surge (IEC 61000-4-5) |
±0.5 kV for Power Line |
Power |
Reverse Polarity Protection |
Yes |
Input Range |
+10 ~ +30 VDC |
Consumption |
1.0 W |
Mechanical |
Dimensions (L x W x H) |
123 mm x 72 mm x 35 mm |
Installation |
DIN-Rail or Wall Mounting |
Environment |
Operating Temperature |
-25 to +75°C |
Storage Temperature |
-40 to +85°C |
Humidity |
10 to 95% RH, Non-condensing |
|
|
 |
I-7018BL CR ~ Will be phased out ~ |
8-channel Analog Input Module using the DCON Protocol (Blue Cover) (RoHS) |
I-7018P CR |
8-channel Analog Input Module using the DCON Protocol (Blue Cover) (RoHS) |
I-7018P-G CR |
8-channel Analog Input Module using the DCON Protocol (Gray Cover) (RoHS) |
|
|
 |
tM-7520U CR |
RS-232 to RS-485 converter (RoHS) |
tM-7561 CR |
USB to RS-485 converter (RoHS) |
tM-SG4 CR |
RS-485 Pull-high/Pull-low and Termination Resistor Module (RoHS) |
I-7514U CR |
4-channel RS-485 Hub (RoHS) |
SG-770 CR |
7 channel differential or 14 channel single-ended surge protector (RoHS) |
SG-3000 Series |
Signal Conditioning Modules for Thermocouple, RTD, DC Voltage, DC Current and Power Input Transformers |
|
|
|
|
|
|
|