Input |
Voltage range |
85 ~ 264 VAC
120 ~ 370 VDC |
Frequency range |
47 ~ 63 Hz |
Efficiency (Typ.) |
84% |
Leakage current (max.) |
0.55 A/115 VAC
0.35 A/230 VAC |
Inrush Current (Typ.) |
COLD START 20 A/115 VAC
40 A/230 VAC |
Leakage current |
<1 mA / 240 VAC |
Output |
DC Voltage |
24 VDC |
Rated Current |
1 A |
Current Range |
0 ~ 1 A |
Rated power |
24 W |
Ripple & noise (max.) Note.2 |
150mVp-p |
Voltage ADJ. range |
21.6 ~ 26.4 V |
Voltage Tolerance Note.3 |
±1.0% |
Line Regulation |
±1.0% |
Load regulation |
±1.0% |
Setup, rise Time Note.5 |
50 ms/230 VAC
0 ms/115 VAC at full load |
Hold up time (Typ.) |
85 ~ 264 VAC
120 ~ 370 VDC |
Protection |
Overload |
105 ~ 160% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
Over voltage |
27.6 ~ 32.4V |
Protection type : Shut down o/p voltage, re-power on to recover |
Function |
DC OK Active Signal (max.) |
18 ~ 27 V/20 mA |
Environmental |
Working temp. |
-20 ~ +70°C (Refer to output load derating curve) |
Working humidity |
20 ~ 90% RH non-condensing |
Storage TEMP., humidity |
-40 ~ +85°C , 10 ~ 95% RH |
TEMP. Coefficient |
±0.03%/°C (0 ~ 50°C) |
Vibration |
Component:10 ~ 500Hz, 2G 10min./1cycle,
60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
Safety & EMC (Note 4) |
Safety standards |
UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant |
Withstand voltage |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5K VAC |
Isolation resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500 VDC |
EMI Conduction & Radiation |
Compliance to EN55011,EN55022 (CISPR22), EN61204-3 Class |
Hsrmonic current |
Compliance to EN61000-3-2,-3 |
EMS immunity |
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A |
Others |
MTBF |
236.9K hrs min.
MIL-HDBK-217F (25°C ) |
Dimension (W x H x D) |
22.5 mm x 90 mm x 100 mm |
Packing |
0.19Kg; 72pcs/14.7Kg/0.91CUFT |
NOTE |
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
|