Model: tGW-700 Series
tGW-712/tGW-722/tGW-732
tGW-715/tGW-725/tGW-735
tGW-718/tGW-724/ tGW-734
Tiny Modbus/TCP to RTU/ASCII gateway Device Servers
 
     
 
 
 
Modbus has become a de facto standard industrial communication protocol, and is now the most commonly available means of connecting industrial electronic devices. Modbus allows for communication between many devices connected to the same RS-485 network, for example, a system that measures temperature and humidity and communicates the results to a computer. Modbus is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.

The tGW-700 is a Modbus TCP to RTU/ASCII gateway that enables a Modbus/TCP host to communicate with serial Modbus RTU/ASCII devices through an Ethernet network, and eliminates the cable length limitation of legacy serial communication devices. The module can be used to create a pair-connection application (as well as serial-bridge or serial-tunnel application), and can then route data over TCP/IP between two serial Modbus RTU/ASCII devices, which is useful when connecting mainframe computers, servers or other serial devices that use Modbus RTU/ASCII protocols and do not themselves have Ethernet capability.

The new read-cache function included in firmware version 1.4.1 is used to store previous requests and responses in the memory buffer of the tGW-700 module. When other HMI/SCADA master controllers send the same requests to the same RTU slave device, the cached response is returned immediately. This feature dramatically reduces the loading on the RS-485 bus communication, ensures faster TCP responses, and improves the stability of the entire system.

DHCP minimizes configuration errors caused by manual IP address configuration, such as address conflicts caused by the assignment of an IP address to more than one computer or device at the same time. The tGW-700 module supports the DHCP client function, which allows it to easily obtain the necessary TCP/IP configuration information from a DHCP server. The module also contains a UDP responder that transmits its IP address information in response to a UDP search from the eSearch utility, making local management more efficient.

The tGW-700 module features a powerful 32-bit MCU to enable efficient handling of network traffic, and also has a built-in web server that provides an intuitive web management interface that allows users to modify the configuration of the module, including the DHCP/Static IP, the gateway/mask settings and the serial port settings.

The module contains a dual watchdog, including a CPU watchdog (for hardware functions) and a host watchdog (for software functions). The CPU watchdog automatically resets the CPU if the built-in firmware is operating abnormally, while the host watchdog automatically resets the CPU if there is no communication between the module and the host (PC or PLC) for a predefined period of time (system timeout). The dual watchdog is an important feature that ensures the module operates continuously, even in harsh environments.

The tGW-700 module offers true IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) functionality using a standard category 5 Ethernet cable to receive power from a PoE switch such as the NS-205PSE. If there is no PoE switch on site, the module will also accept power input from a DC adapter. The tGW-700 module is designed for ultra-low power consumption, reducing hidden costs from increasing fuel and electricity prices, especially when you have a large number of modules installed. Reducing the amount of electricity consumed by choosing energy-efficient equipment can have a positive impact on maintaining a green environment.

The module is equipped with a male DB-9 or a removable terminal block connector to allow easy wiring. Based on an amazing tiny form-factor, the tGW-700 achieves maximum space savings that allows it to be easily installed anywhere, even directly embedded into a machine. It also supports automatic RS-485 direction control when sending and receiving data, thereby improving the stability of the RS-485 communication.
 
 
 
     
   
     
 
 
 
  • Supports Modbus TCP/UDP master and slave
  • Supports Modbus RTU/ASCII master and slave
  • Max. connections (masters) per serial port: 32 (tGW-71x), 16 (tGW-72x) or 10 (tGW-73x)
  • Read-cache ensures faster Modbus TCP/UDP response
  • Supports UDP responder for device discovery (UDP Search)
  • Static IP or DHCP network configuration
  • Easy firmware update via the Ethernet (BOOTP, TFTP)
  • Tiny Web server for configuration (HTTP)
  • Contains a 32-bit MCU that efficiently handles network traffic
  • 10/100 Base-TX Ethernet, RJ-45 x 1 (Auto-negotiating, auto MDI/MDIX, LED Indicators)
  • Includes redundant power inputs: PoE (IEEE 802.3af, Class 1) and DC jack
  • Allows automatic RS-485 direction control
  • Male DB-9 or terminal block connector for easy wiring
  • Tiny form-factor and low power consumption
  • RoHS compliant & no Halogen
  • Cost-effective Modbus Gateway
 
 
 
  back  
   
 
 
 
  • Factory , Building and Home Automation
  • Remote Diagnosis and Management
 
     
  back  
     
 
Spec
 
 
Model tGW-712 tGW-722 tGW-732 tGW-715 tGW-725 tGW-735 tGW-718 tGW-724 tGW-734
System
CPU 32-bit ARM
Communication Interface
Ethernet 10/100 Base-TX, 8-pin RJ-45 x 1,
(Auto-negotiating, Auto-MDI/MDIX, LED indicator)
PoE (IEEE 802.3af, Class 1)
COM1 (TCP Port: 502) 5-wire RS-232 5-wire RS-232 3-wire RS-232 2-wireRS-485
4-wire RS-422
2-wire RS-485 2-wire RS-485 3-wire RS-232 2-wire RS-485 2-wire RS-485
2-wireRS-485
4-wire RS-422
COM2 (TCP Port: 503) - 5-wire RS-232 3-wire RS-232 - 2-wire RS-485 2-wire RS-485 - 5-wire RS-232 3-wire RS-232
COM3 (TCP Port: 504) - - 3-wire RS-232 - - 2-wire RS-485 - - 3-wire RS-232
Self-Tuner - Yes, automatic RS-485 direction control
RS-485 Bias Resistor - Yes, 1 K£[
Node - 254 (max.)
UART 16c550 or compatible
COM Port Format
Baud Rate 115200 bps Max.
Data Bit 5, 6, 7, 8
Parity None, Odd, Even, Mark, Space
Stop Bit 1, 2
Power
Power Input PoE: IEEE 802.3af, Class 1
DC jack: +12 ~ 48 VDC
Power Consumption 0.07 A @ 24 VDC
Mechanism
Connector Male DB-9 x 1 10-Pin Removable Terminal Block x 1
Mounting DIN-Rail
Flammability Fire Retardant Materials (UL94-V0 Level)
Environment
Operating Temperature -25 ~ +75 ¢XC
Storage Temperature -30 ~ +80 ¢XC
Humidity 10 ~ 90% RH, non-condensing
 
     
   
   
 
 
 
Model RS-232 RS-422/485 RS-485 CPU Ethernet Baud Rate COM1
TCP Port: 502
COM2
TCP Port: 503
COM3
TCP Port: 504
tGW-712 1 - - 32-bit ARM 10/100 Base-TX, PoE 115200 bps 5-wire RS-232 - -
tGW-722 2 - - 5-wire RS-232 5-wire RS-232 -
tGW-732 2 - - 3-wire RS-232 3-wire RS-232 3-wire RS-232
tGW-715 - 1 - 2-wire RS-485
4-wire RS-422
- -
tGW-725 - - 2 2-wire RS-485 2-wire RS-485 -
tGW-735 - - 3 2-wire RS-485 2-wire RS-485 2-wire RS-485
tGW-718 1 - 3-wire RS-232 - -
2-wire RS-485
4-wire RS-422
tGW-724 1 - 1 2-wire RS-485 5-wire RS-232 -
tGW-734 2 - 1 2-wire RS-485 3-wire RS-232 3-wire RS-232
 
     
   
     
 
 
 
tGW-712 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 1 RS-232 Port (RoHS)
tGW-722 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 2 RS-232 Ports (RoHS)
tGW-732 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 3 RS-232 Ports (RoHS)
tGW-715 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 1 RS-422/485 (RoHS)
tGW-725 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 2 RS-485 Ports (RoHS)
tGW-735 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 3 RS-485 Ports (RoHS)
tGW-718 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 1 RS-232/422/485 Port (RoHS)
tGW-724 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 1 RS-232 and 1 485 Ports (RoHS)
tGW-734 CR Tiny Modbus/TCP to RTU/ASCII gateway with PoE and 2 RS-232 and 1 485 Ports (RoHS)
Includes one CA-002 cable.
 
   
     
   
     
 
 
 
CA-002 DC connector to 2-wire power cable, 0.3 M
CA-PC09F DB-9 Female connector with plastic cover
CA-0910N DB-9 Female-Female 3-wire Null Modem Cable, 1 M
CA-0915 Male DB-9 to Female DB-9 Cable, 1.5 m
CA-0910F Female DB-9 to Female DB-9 Cable, 1.0 m
CA-0909 Female DB-9 to Female DB-9 connector for tDS-712/tGW-712.
NS-205 CR Unmanaged 5-Port Industrial Ethernet Switch (RoHS)
NS-205PSE CR Unmanaged Ethernet Switch with 4 PoE Ports and 1 RJ-45 Uplink (RoHS)
FRA05-S12-SU 12 V/0.58 A (max) Power Supply.
 
     
   
     
 
 
 
PDS Series Main Page
 
     
   
     