P8R8DIO
Isolated 8 Digital Input & Relay Output Board |
|
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
The P8R8 DIO is a 8 Isolated input and 8 relay output interface board designed for control and sensing applications. This interface board is easily installed in any PC/AT/XT or compatible computer. The P8R8 DIO Provides 8 electromechanical relay outputs and 8 optically isolated inputs. The P8R8 DIO can be used in various applications including load switching, external switching, contact closure, etc.
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
- Relay output Channel
- optically isolated digital input channels
- AC/DC signal Input ; AC signal input with filter
- Connector pin assignment is compatible to 725 series
- Power Requirements : +5V 200mA(max.) ; +12V 260 mA (max.)
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
- Factory Automation
- Product Test
- Laboratory Automation
- Security Control
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
- Toolkit for DOS
- Toolkit for Windows 95/98
- Toolkit for Windows NT
- Toolkit for Windows 2000/XP
- Toolkit for Labview 95/98
- Toolkit for Labview NT
|
- Toolkit for Labview 2000/XP
- ActiveX Control (OCX) 95/98
- ActiveX Control (OCX) NT
- ActiveX Control (OCX) 2000/XP
- Toolkit for LINUX
- Toolkit for DasyLab
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
| Relays |
Relay output Channels |
8 |
Contact Rating |
0.3 A ;120V AC/DC / 1A ; 30Vdc |
Contact arrangement |
Output channel 0-3 are Form C (Output channel 4-7 are Form A) |
Operating time |
5m Sec |
Release time |
10m Sec |
Expected life > 100,000 times (Electrical at 30V/1A) |
Inputs |
Channels |
8 |
Type |
Non-polarized OPTO-isolated , (PC-814) |
Input Voltage |
AC/DC 5-24V ( Vac Feq:50~1Khz) |
Input Impedance |
1.2 KW |
Response Time |
20mS ( Without filter)22mS ( With filter) |
Isolation |
500V channel-channel & channel-ground |
Environmental |
Operating temperature |
0~60¢XC |
Storage temperature |
-20~70¢XC |
Humidity |
0 to 90% non-condensing |
Dimensions |
Dimensions |
175 mm x 121 mm |
|
|
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
| P8R8DIO |
8-channel Isolated D/I and Relay Output Includes one CA-4002 D-Sub connector. |
| P8R8DIO CR |
8-channel Isolated D/I and Relay Output (RoHS) Includes one CA-4002 D-Sub connector. |
|
|
|
|
| |
back |
|
|
|
|
| |
|
|
| |
|
|
| |
| DB-37 |
Directly connect signal to D-sub 37-pin connector |
| DN-37 |
DIN Rail Mounting 37-pin Connector |
| CA-4002 |
37-pin Male D-sub connector with plastic cover |
|
|
|
|
| |
|
|
|
|
|
| |
back |
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
|
| |