P8R8DIO
Isolated 8 Digital Input & Relay Output Board
 
 
Model: P8R8DIO
     
 
     
 
 
 

The P8R8 DIO is a 8 Isolated input and 8 relay output interface board designed for control and sensing applications. This interface board is easily installed in any PC/AT/XT or compatible computer. The P8R8 DIO Provides 8 electromechanical relay outputs and 8 optically isolated inputs. The P8R8 DIO can be used in various applications including load switching, external switching, contact closure, etc.

 
  back  
     
 
 
 
  • Relay output Channel
  • optically isolated digital input channels
  • AC/DC signal Input ; AC signal input with filter
  • Connector pin assignment is compatible to 725 series
  • Power Requirements : +5V 200mA(max.) ; +12V 260 mA (max.)
 
  back  
     
 
 
 
  • Factory Automation
  • Product Test
  • Laboratory Automation
  • Security Control
 
  back  
     
 
 
 
  • Toolkit for DOS
  • Toolkit for Windows 95/98
  • Toolkit for Windows NT
  • Toolkit for Windows 2000/XP
  • Toolkit for Labview 95/98
  • Toolkit for Labview NT
  • Toolkit for Labview 2000/XP
  • ActiveX Control (OCX) 95/98
  • ActiveX Control (OCX) NT
  • ActiveX Control (OCX) 2000/XP
  • Toolkit for LINUX
  • Toolkit for DasyLab
 
  back  
     
 
 
 
Relays
Relay output Channels
8
Contact Rating
0.3 A ;120V AC/DC / 1A ; 30Vdc
Contact arrangement
Output channel 0-3 are Form C (Output channel 4-7 are Form A)
Operating time
5m Sec
Release time
10m Sec
Expected life > 100,000 times (Electrical at 30V/1A)
Inputs
Channels
8
Type
Non-polarized OPTO-isolated , (PC-814)
Input Voltage
AC/DC 5-24V ( Vac Feq:50~1Khz)
Input Impedance
1.2 KW
Response Time
20mS ( Without filter)22mS ( With filter)
Isolation
500V channel-channel & channel-ground
Environmental
Operating temperature
0~60¢XC
Storage temperature
-20~70¢XC
Humidity
0 to 90% non-condensing
Dimensions
Dimensions
175 mm x 121 mm
 
  back  
     
 
 
 
P8R8DIO 8-channel Isolated D/I and Relay Output
Includes one CA-4002 D-Sub connector.
P8R8DIO CR 8-channel Isolated D/I and Relay Output (RoHS)
Includes one CA-4002 D-Sub connector.
 
  back  
     
 
 
 
DB-37 Directly connect signal to D-sub 37-pin connector
DN-37 DIN Rail Mounting 37-pin Connector
CA-4002 37-pin Male D-sub connector with plastic cover

 
     
  back  
     
 
 
 
I/O Card Main Page
 
     
  back  
     
Copyright© ICP DAS Co., Ltd. All Rights Reserved