ISO-C64
64-channel Optically Isolated Open-collector Digital Output Board |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The ISO-C64 has 64 channels of optically isolated digital outputs, arranged into four isolated banks. Each digital output offers a darlington transistor and integral suppression diode for inductive load. Isolated output channels are designed into group A, B, C, D. The power supply of the output port should be use the external power. This board interface to field logic signals, eliminating ground-loop problems and isolating the host computer from damaging voltages. |
|
|
|
back |
|
|
|
|
|
|
|
|
|
|
|
- 64-channel optically isolated digital output / Open-collector
- Four isolated bank
- 3750 Vrms isolation voltage
|
|
|
|
back |
|
|
|
|
|
|
|
|
|
|
|
- Factory Automation
- Product Test
- Laboratory Automation
|
|
|
|
back |
|
|
|
|
|
|
|
|
|
|
|
- DOS sample program(with source codes)
- DLL and OCX SDK for Windows 98/NT/2000
- DLL and OCX SDK for 32-bit Windows XP/2003/Vista/7
- VB/VC/Delphi/BCB sample programs with source codes are included
- LabVIEW toolkit for Windows
- Driver for DasyLab
|
|
|
|
|
|
|
|
|
|
back |
|
|
|
|
|
|
|
|
Digital Output |
Isolation Voltage |
3750 Vrms (Using external power) |
Channels |
64 |
Compatibility |
Sink, Open Collector |
External Voltage |
5 ~ 30 VDC (max.) |
Output Capability |
100 mA for one low driving channel @ 100% duty
100 mA for all low driving channels @ 60% duty |
Response Speed |
4 kHz (Typical) |
General |
Bus Type |
ISA |
Data Bus |
8-bit |
I/O Connector |
Female DB37 x 1
40-pin Box header x 1 |
Dimensions (L x W x D) |
178 mm x 115 mm x 22 mm |
Power Consumption |
500 mA @ +5 V |
Operating Temperature |
0 ~ 60 ¢XC |
Storage Temperature |
-20 ~ 70 ¢XC |
Humidity |
5 ~ 85% RH, non-condensing |
|
|
|
|
|
|
|
|
|
|
|
|
back |
|
|
|
|
|
|
|
|
ISO-C64 CR |
Isolated 64-chanel digital Output Board (RoHS)
Includes one CA-4037W cable and two CA-4002 D-Sub connectors. |
|
|
|
|
|
|
|
|
|
|
|
back |
|
|
|
|
|
|
|
|
CA-3710 |
DB-37 Male-Male D-sub cable 1 M (Cable for Daughter Board(45¢X)) |
CA-3710D |
DB-37 Male-Male D-sub cable 1M (Cable for Daughter Board(180¢X)) |
CA-3715DM-H |
DB-37 Male-Male Cable, 1.5 M, 180¢X. (RoHS) |
CA-3730DM-H |
DB-37 Male-Male Cable, 3.0 M, 180¢X. (RoHS) |
CA-3750DM |
DB-37 Male-Male Cable, 5.0 M, 180¢X. (RoHS) |
CA-3750DM-H |
DB-37 Male-Male Cable, 5.0 M, 180¢X. (RoHS) |
CA-4002 |
37-pin Male D-sub connector with plastic cover |
CA-4037W |
40-pin flat & D-sub 37-pin Female cable 24 cm. |
DB-37 |
Directly connect signal to D-sub 37-pin connector |
DN-37 |
DIN Rail Mounting 37-pin Connector |
DB-32R |
32-channel relay output board
Include : CA-3710D Male- Male D-sub Cable 1.0 M |
|
|
|
|
|
|
|
|
|
|
|
back |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
back |
|
|
|
|