PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organization (PI). Based on Ethernet versatility, PROFINET make vertical integration of field level with Enterprise level easily. PROFINET is automation in real time, so it can cover all requirements of the Automation Industry. PROFINET is fit for factory automation, process automation, safety applications and motion control applications, etc.

PROFINET allows existing field bus systems such as PROFIBUS DP, PROFIBUS PA, AS-Interface, INTERBUS and DeviceNet to be integrated without changes to existing field devices. It means the investments of field devices and applications are all protected.

 

The PROFINET standard defines three different performance levels which cover the various requirements from different applications.

PROFINET NRT (Non Real Time): It uses standard protocols as UDP/IP. With response time approx. 100 ms PROFINET NRT targets for applications in process automation.

PROFINET RT (Real Time): For applications with higher requirements on cycle time like factory automation, it directly uses the Ethernet protocol to exchange I/O data, while diagnosis and configuration uses standard UDP/IP. PROFINET RT enables applications with response time approx. 10 ms.

PROFINET IRT (Isochronous Real Time): The highest requirements come from the control of complex industrial drive systems, like packaging machines or robotics. With applications with cycle time < 1 ms and jitter < 1 μs are possible.

Applications

  • Industrial Automation
  • Factory Automation
  • Process Automation
  • Etc…
      

Features 

  • Transfer protocol: PROFINET IO
  • Supported Ethernet services: ICMP, IGMP, ARP, DHCP, TELNET, TFTP, SNMP, VLAN Priority Tagging
  • Supported PROFINET services: RTC, RTA, CL-RPC, DCP, LLDP, I&M
  • PROFINET Conformance Class B and RT Class 1
  • Cyclic Time: 1ms (min)
  • Generic GSDML File Provided
  • Automatic MDI / MDI-X Crossover for Plug-and-play
Model Analog Input Modules
Module Name PFN-2019/S
 
Channels 10 (Differential)
Sensor Type Thermocouple (J, K, T, E, R, S, B, N, C)
Voltage Input Range ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V,
±2.5 V, ±5 V, ±10 V
Current Input Range ±20 mA, 0 ~ +20 mA, +4 mA ~ +20 mA
(Jumper Selectable)
Resolution 16-bit
Sampling Rate 10 Hz
Accuracy ±0.1% of FSR
EDS Protection 4 kV Contact for each channel
 
 
Model Analog Output Modules
Module Name PFN-2024
 
Channels 4
Voltage Output Range 0 ~ 5 V, ±5 V, 0 ~ 10 V, ±10 V
Current Output Range 0 ~ 20 mA, 4 ~ 20 mA
Resolution 16-bit
Accuracy Voltage Output ±0.1% of FSR
Current Output ±0.1% of FSR
ESD Protection 4 kV Contact for each channel
 
Model Digital Input & Output Module
Module Name PFN-2042
 
PFN-2051
 
PFN-2052
 
PFN-2053
 
PFN-2055
 
PFN-2060
 
Digital Input
Channels  - 16 8 16 8 6
Contact Dry + Wet Wet Dry Dry + Wet Dry + Wet
Sink/Source (NPN/PNP) Dry: Source
Wet: Sink/Source
Sink/Source Source Dry: Source
Wet: Sink/Source
Dry: Source
Wet: Sink/Source
Wet Contact On Voltage Level +10 ~ 50 VDC +4 ~ 30 VDC - +10 ~ 50 VDC +10 ~ 50 VDC
Wet Contact Off Voltage Level +4 VDC Max. +1 VDC Max. - +4 VDC Max. +4 VDC Max.
Dry Contact On Voltage Level Close to GND - Close to GND Close to GND Close to GND
Dry Contact Off Voltage Level Open - Open Open Open
Input Impedance 10 kΩ, 0.5 W 3 KΩ, 0.3 W 3 kΩ, 0.3 W 10 kΩ, 0.5 W 10 kΩ, 0.5 W
Digital Output
Channels 16  -  -  - 8 6
Type Open Collector Open Collector Power Relay
Sink/Source (NPN/PNP) Sink Sink Form A
Load Voltage +3.5 ~ +50 VDC +3.5 ~ +50 VDC 30 VDC/125 VAC
Max. Load Current 700 mA/Channel 700 mA/Channel 2 A @ 30 VDC,
0.6 A @ 125 VAC
Overvoltage Protection 60 VDC 60 VDC -
Overload Protection Yes Yes -
Power-on Value Yes Yes Yes
Safe Value Yes Yes Yes
 
Converter & Gateway Modules
Model Description
Converter I-7580
 
PROFINET to RS-232/422/485 Converter
Gateway GW-7662
 
PROFINET to Modbus RTU/ASCII Gateway
GW-7663
 
PROFINET to Modbus TCP Gateway