The PET-7H16M/PET-7H24M/PET-AR400 is an high speed data acquisition devices.

PET-7H16M

The PET-7H16M is an high speed data acquisition devices built-in a Ethernet communication port for data transfer over the network and it includes eight high speed 16-bit single-ended analog inputs (200 KHz sample and hold for 8 channels), 4-channel digital inputs and 4-channel digital outputs. It provides programmable input range on all analog channels (±5 V and ±10 V), digital output can be set output with Short-circuit protection and overload protection. The counter value of 4-channel Low-speed DI counters and 1-channel High-speed counter are latched by ADC sampling time synchronously. PET-7H16M also has qualification for 4 kV ESD protection as well as 2500 VDC intra module isolation. In addition, the 16-bit ADC includes built-in anti-aliasing filtering to adjust the appropriate sampling rate and filter out modulator and signal noise. The PET-7H16M is not only suitable for a wide range of mobile/portable measurement applications, but also for precision signal measurement.

PET-7H16M supports more kinds of trigger modes for A/D conversion: software trigger, external clock trigger , external digital trigger (Post-trigger/Pre-trigger/Delay-trigger)and analog threshold trigger. The software trigger can acquire a sample whenever needed, while the internal pacer saves CPU loading by triggering the sampling at pre-programmed frequency. An external clock trigger can be used for triggering by external frequency source. Analog threshold trigger mode, when the analog input value is higher or lower than the set specific voltage value, it triggers, and the A/D collection of N data is started.

PET-7H24M

The PET-7H24M is an high speed data acquisition devices built-in a Ethernet communication port for data transfer over the network and it includes 4 high-speed 24-bit differential Analog input channels analog inputs (128 KHz sample and hold for 4 channels), 2 Analog Output channels, 3 Digital Input channels, 4 Digital Output channels and 1 Encoder Input channel. The module provides a programmable input range on all analog channels, and the Digital Output can be set to output with short-circuit and over load protection. 1 Encoder Input channel can be configured as Quadrant, Pulse/Direction or CW/CCW input mode. The PET-7H24M also provides 4 kV ESD protection as well as 2500 VDC intra-module isolation. In addition, the 24-bit ADC includes built-in Sinc3 filtering to adjust the appropriate sampling rate and filter out modulator and signal noise. The PET-7H24M is not only suitable for a wide range of mobile/portable measurement applications, but also for precision signal measurement.

PET-7H24M supports more kinds of trigger modes for A/D conversion: software trigger, Analog threshold trigger. The software trigger can acquire a sample whenever needed, Analog threshold trigger, when the analog input value is higher or lower than the set specific voltage value, it triggers, and the A/D collection of N data is started.

PET-AR400

PET-AR400 is a high-precision dynamic signal data acquisition module with Ethernet network, which is used to measure piezoelectric (IEPE) sensors, such as accelerometers, etc. It can simultaneously collect 4-channel analog input signals, and the sampling frequency Up to 128 kHz @ single channel

PET-AR400 also has 4 kV electrostatic protection and 2500 VDC internal isolation, which has extremely high stability characteristics. In addition, the 24-bit ADC also includes built-in filtering function, which can adjust the appropriate sampling rate and filter out signal noise. PET-AR400 is suitable for various mobile/portable measurement applications, as well as precision signal measurement, and supports software trigger and analog input level trigger. The software trigger mode can trigger the A/D acquisition of continuous or N data when needed. Analog input level trigger mode, trigger when the analog input value is higher or lower than the set specific voltage value, and start A/D acquisition of N data.

Particular Features

PET-7H16M

  1. Continuous Transmission (Maximum sampling rate of 30 kHz per channel)
  2. After starting A/D acquisition, data is continuously transmitted to the Host PC

    Total simultaneous sampling channels Maximum sampling rate per channel
    8 30 KHz
    4 60 KHz
    2 120 KHz
    1 200 KHz
  3. After collecting N data samples, the data is transferred to the Host PC (Maximum sampling rate of 200 kHz per channel)
  • After starting A/D acquisition, the data will be temporarily stored in the memory on the PET-7H16M module, and wait until a command is received from the Host PC, before transferring the collected data to the Host PC

  • The memory capacity allows temporary storage of up to 30 million data samples, Storage time:

    (b1) 125 seconds at a sampling rate of 30 kHz

    (b2) 19.6 seconds at a sampling rate of 200 kHz

Total simultaneous sampling channels Maximum sampling rate per channel
1 ~ 8 200 KHz
  1. Software A/D Data Acquisition Mode
  2. The A/D acquisition parameters are configured via a command from the Host PC. The continuous A/D acquisition or the acquisition of N data samples begins after the command is triggered.

  3. External Digital Signal Event Trigger Mode
  4. The A/D acquisition parameters are configured via a command from the Host PC, and then triggered via an external electrical signal. The A/D acquisition of the N data samples is then started.

  5. Analog threshold trigger Mode
  6. The A/D acquisition parameters are configured via a command from the Host PC, When the analog input value is higher or lower than the set specific voltage value, the A/D acquisition of the N data is started.

  7. External Clock A/D Conversion Data Acquisition Mode
  8. The speed of the A/D acquisition and the amount of data acquired are controlled by external electrical signals. A falling edge for each output waveform triggers an AD conversion.

A/D acquisition is performed in external digital event trigger mode (triggering the electrical signal is the falling edge trigger). The maximum sampling rate per channel is 200 kHz, and A/D acquisition of N data samples is performed. The acquisition mode can be categorized into three types.

  • Pre-Trigger (acquisition of N data samples)
  • The A/D data is continually collected and is temporarily stored in the memory on the PET-7H16M until the trigger signal is received. Once the trigger signal is received, the collected N data samples are then transferred to the Host PC.

  • Post-Trigger (acquisition of N data samples)
  • In this mode, the A/D acquisition of the N data samples is started once the trigger signal is received.

  • Delay-Trigger (acquisition of N data samples)
  • The A/D acquisition of the N data samples is started once the programmed delay period from the trigger has elapsed.

Analog threshold trigger is triggered when the voltage signal of the specified analog input channel is higher or lower than a certain voltage setting. In addition, the user can also specify the trigger voltage level range of the input signal. Once the signal leaves the high and low level region or the signal enters the high and low level region, it is triggered to start the acquisition.

  1. Above High: The signal is triggered above the high level and collects N data.
  2. Below Low : The signal is triggered below the low level and collects N data.
  3. Leave-region : Trigger when the signal leaves the high and low level region, collect N data.
  4. Entry-region : Trigger when the signal enters the high and low level region, collect N data.

The A/D acquisition parameters are configured via a command from the Host PC, and are triggered by an external digital signal event, the A/D acquisition of N data samples, or A/D acquisition via the synchronization of an external clock signal.

The PET-7h16M is equipped with 4-channel low-speed counters and 1-channel high-speed counter. It can be set to read the counter input synchronously with the A/D sampling time. The counter inputs can be read asynchronously by the software at any time and the counter inputs are also read synchronously with the analog input at the set sampling time. The high speed counter input is the same channel as the hardware trig + / trig- input. If the trig + / trig- input is set to the counter input. External digital signal event triggering and external clock A/D conversion data acquisition cannot be used.

The features of the previous 1~4 are all about A/D high-speed acquisition, data transmission and trigger mode. In addition to the high-speed acquisition of the analog input, other digital input/digital output read-back and counter input can also be read simultaneously, and these acquisition data can also be transferred to the Host PC with the Analog input sampling data. It is flexibly to define different input types into the Ethernet data frame of synchronous input data acquisition. In synchronous input data acquisition, the sampling rate can be 2KHZ Max. The Transmit packet of the synchronous input data acquisition is embedded in the Ethernet frame with user-defined data frames. Here are some examples below.

  1. The following user-defined frame consists of 8-channel AI value and 1-channel high-speed counter value.
  2. The following user-defined frame consists of the index header, 8-channel AI value and 1-channel high-speed counter value.
  3. The following user-defined frame consists of a timestamp header, an 8-channel AI value, a 4-channel DI value, a 2-channel low-speed counter value, and a 1-channel high-speed counter value.

PET-7H24M

  1. Continuous Transmission (Maximum sampling rate of 60 kHz per channel)
  2. After starting A/D acquisition, data is continuously transmitted to the Host PC

    Total simultaneous sampling channels Maximum sampling rate per channel
    2 ~ 4 60 kHz
  3. After collecting N data samples, the data is transferred to the Host PC (Maximum sampling rate of 128 kHz per channel)
  • After starting A/D acquisition, the data will be temporarily stored in the memory on the PET-7H24M module, and wait until a command is received from the Host PC, before transferring the collected data to the Host PC

  • The memory capacity allows temporary storage of up to 15 million data samples, Storage time:

    (b1) 62.5 seconds at a sampling rate of 60 kHz

    (b2) 29.3 seconds at a sampling rate of 128 kHz

Total simultaneous sampling channels Maximum sampling rate per channel
1 ~ 4 128 kHz
  1. Software A/D Data Acquisition Mode
  2. The A/D acquisition parameters are configured via a command from the Host PC. The continuous A/D acquisition or the acquisition of N data samples begins after the command is triggered.

  3. Analog Threshold Trigger Mode
  4. The A/D acquisition parameters are configured via a command from the Host PC, and then triggered via an external electrical signal. The A/D acquisition of the N data samples is then started.

Analog Threshold Trigger is triggered when the voltage signal of the specified analog input channel is higher or lower than a certain voltage setting. In addition, the user can also specify the trigger voltage level range of the input signal. Once the signal leaves the high and low level region or the signal enters the high and low level region, it is triggered to start the acquisition.

  1. Above High: The signal is triggered above the high level and collects N data.
  2. Below Low : The signal is triggered below the low level and collects N data.
  3. Leave-region : Trigger when the signal leaves the high and low level region, collect N data.
  4. Entry-region : Trigger when the signal enters the high and low level region, collect N data.

PET-AR400

  1. Continuous Transmission
  2. Total simultaneous sampling channels Maximum sampling rate per channel
    1 12.8k/16k/32k/64k/128k Hz
    2 12.8k/16k/32k/64k Hz
    3/4 12.8k/16k/32k Hz
  3. N Sample Acquisition
  • After starting A/D acquisition, the data will be temporarily stored in the memory on the PET-AR400 module, and wait until a command is received from the Host PC, before transferring the collected data to the Host PC

  • The memory capacity allows temporary storage of up to 15 million data samples, Storage time:

    (b1) 117.2 seconds at a sampling rate of 32 kHz

    (b2) 117.2 seconds at a sampling rate of 128 kHz

Total simultaneous sampling channels Maximum sampling rate per channel
1 12.8k/16k/32k/64k/128k Hz
2 12.8k/16k/32k/64k Hz
3/4 12.8k/16k/32k Hz
  1. Software A/D Data Acquisition Mode
  2. The A/D acquisition parameters are configured via a command from the Host PC. The continuous A/D acquisition or the acquisition of N data samples begins after the command is triggered.

  3. Analog Threshold Trigger Mode
  4. The A/D acquisition parameters are configured via a command from the Host PC, and then triggered via an external electrical signal. The A/D acquisition of the N data samples is then started.

Analog Threshold Trigger is triggered when the voltage signal of the specified analog input channel is higher or lower than a certain voltage setting. In addition, the user can also specify the trigger voltage level range of the input signal. Once the signal leaves the high and low level region or the signal enters the high and low level region, it is triggered to start the acquisition.

  1. Above High: The signal is triggered above the high level and collects N data.
  2. Below Low : The signal is triggered below the low level and collects N data.
  3. Leave-region : Trigger when the signal leaves the high and low level region, collect N data.
  4. Entry-region : Trigger when the signal enters the high and low level region, collect N data.

Common Features

  1. Windows
  2. 。Microsoft VC, C#, VB.NET SDK API and Demo

    。Python and Demo

    。NI LabVIEW Toolkit and Demo

  3. Linux
  4. 。C/C++ library and Demo

    。.NET library and Demo

    。Python and Demo

Each PET-7H16M/PET-7H24M/PET-AR400 module has a built-in web server that allows users to easily configure, monitor and control the module from a remote location using a regular web browser.

Account and password are required when logging into the PET-7H16M/PET-7H24M/PET-AR400 web server. An IP address filter is also included, which can be used to allow or deny connections with specific IP addresses.

The Modbus/TCP slave function on the Ethernet port can be used to provide data to remote HMI/SCADA software built with Modbus/TCP driver.

RJ-45 port supports automatic MDI/MDI-x that can automatically detect the type of connection to the Ethernet device without requiring special straight or crossover cables.

PET-7H16M/PET-7H24M/PET-AR400 is housed in a metal shell/case with a column-like ventilator that helps to cool the working environment inside the shell/case.

。Operating Temperature: -25 ~ +75 °C

。Storage Temperature: -30 ~ +80 °C

。Humidity: 10 ~ 90 % RH (non-condensing)

"P" of PET-7H16M/PET-7H24M/PET-AR400 means PoE function. The module has integrated Power-over-Ethernet (PoE), it allows power and data to be carried over a single Ethernet cable, so a device can operate solely from the power it receives through the data cable. This innovation allows greater flexibility in office design, higher efficiency in systems design, and faster turnaround time in set-up and implementation. The module feature true IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) using both Ethernet pairs (Category 5 Ethernet cable). The module can receive power from an auxiliary power sources like AC adapters and battery in addition to the PoE enabled network. This is a desirable feature when the total system power requirements exceed the PSE’s (power sourcing equipment) load capacity. Furthermore, with the auxiliary power option, the module can be used in a standard Ethernet (non-PoE) system.

When using PoE devices like PET-7H16M/PET-7H24M/PET-AR400, you can choose ICP DAS “PoE” switch —“NS-205PSE” as the power source, NS-205PSE automatically detects the connected devices whether they are PoE devices or not. This mechanism ensures NS-205PSE to work with both PoE and non-PoE devices coordinately at the same time. Being as a power source for PoE devices, NS-205PSE requires its power input ranging from +46 ~ +55 VDC.

Ethernet High Speed Data Acquisition Module with PoE
Model PET-7H16M  PET-7H24M  PET-AR400 
Analog Input Channels 8 Single-ended (Simultaneously) 4 differential (Simultaneously)
Resolution 16-bit 24-bit
Signal Type Voltage IEPE
Range Bipolar Input
(Programmable): ± 10 V, ± 5 V
± 10 V, ± 5 V, ± 2.5 V, ± 1.25 V
± 0.625 V, ± 300 mV, ± 150 mV,
± 75 mV, ± 40 mV, ± 20 mV
±10 V
Sampling Rate 200 kS/s (Each channel) 128 kS/s (Each channel) 128 kS/s (One channel)
32 kS/s (4 channels)
Analog Output Channels - 2 -
Voltage Output - ± 10 V, ± 5 V, 0 ~ 5 V, 0 ~ 10 V -
Resolution - 12-bit -
Digital Input Channels 4 3 -
Type Wet (Sink) Wet (Sink/Source) -
Digital Output Channels 4 -
Type Wet (Sink) -
Encoder Input Channels - 1 -
Type - Quadrant CW/CCW Pulse/Dir -
 

PET-7H16M/PET-7H24M

Ethernet has many advantages such as standard reliability, easy installation, long transmission distance and fast transmission speed. Its openness and popularity are not only widely used in the integration of IT, enterprise and field, but also become the mainstream specification for industrial communication.

At present, most of the high-speed synchronous data capture systems are mostly collected by a computer host with data capture cards. When the number of channels increases, more data is needed to capture the card. If the devices to collect data are distributed across multiple sites, you will need to increase the number of computer hosts. At this time, the PET-7H16M/PET-7H24M is used instead of the configuration of the computer and data capture card. The data collected from different sites can be transmitted to the central monitoring computer through the network, which can greatly reduce the complexity and time cost of the built wiring, and has the advantages of real-time monitoring. Of device status and centralized data management. The module can be used for continuous data acquisition, high-speed interval acquisition, and simultaneous acquisition with multiple channels. The maximum acquisition speed of each AI channel can exceed 100 kHz. It is suitable for high-speed data acquisition of various mechanical, electronic and physical signals in industrial production, automatic control, electrochemistry, medicine, etc.

The Raspberry Pi open hardware creates diversified and customized applications in the age of Internet of Things. With python (the most popular development tool for the IoT) or Microsoft's cross-platform development tool .Net, it can provide products and various services more quickly. Raspberry Pi users use the python/.Net library and sample programs provided by the ICP DAS high-speed data acquisition module platform to connect to the PET-7H16M/PET-7H24M to collect high-speed data for data analysis and IoT applications.

Strain gauges have been used for stress and strain monitoring of bridges, pipelines, railway tracks, etc. for some time. PET-7H24M has high precision (+/- 20mV range is ±0.2% of FSR) and a variety of low voltage (mV) input ranges, and each AI channel has a maximum acquisition speed of 128kHz, allowing faster and accurate real-time measurement of multiple channels value change of the strain gauge. In this case, 150 strain gauges are measured. The acquisition rate of each channel needs to be greater than 100Hz. Each strain gauge +/- 20mV is output to one AI channel of PET-7H24M, and one PET-7H24M is used for every four channels, totaling 38 sets PET-7H24M. (The excitation voltage of the strain gauge is supplied by an external circuit).

The SG-3000 Series Signal Conditioning Module can be connected to a variety of sensors for current, voltage, thermocouple, resistance temperature sensor (RTD), strain gauge (Strain Gauge), accelerometer Different input signals such as (IEPE Accelerometer) are filtered, isolated, amplified, and converted into an analog voltage or current output in the general measurement range. PET-7H16M/PET-7H24M plus SG-3000 series signal conditioning module will not only monitor voltage, current, temperature, strain, vibration and other diversified signals, but also collect real-time data from different regions and transmit it to the central management system via Ethernet.

Models SG-3011/H SG-3013 SG-3016 SG-3227
Analog Input
Channels 1 2
Signal Thermocouple RTD Strain Gauge IEPE Signal Conditioner
Type J, K, T, E, R, S, B, N, C, L, M, L2 Pt100, Ni120, Pt1000 ±10, ±20, ±30, ±50, ±100 mV IEPE Current: 2, 4, 6, 10 ±5 % mA
AC Signal Gain: 1, 10, 100 ±2 %
High Pass Filter: 10 Hz
Low Pass Filter: x1, x10: 80 kHz; x100: 50 kHz
Analog Output
Channels 1 2
Signal 0 ~ 10 V, 0 ~ 20 mA 0 ~ 5, 0 ~ 10 V
0 ~ 20, 4 ~ 20 mA
±5, ±10, 0 ~ 5, 0 ~ 10 V,
0 ~ 20 mA
AC Couple: ±10 V,
DC Couple: 1 ~ 28 V
Others
Applications 。HVAC/Air conditioning control
。Petrochemical industry
。Electronic/semiconductor equipment
。Water treatment equipment
。Pot/heating industry
。Hot pressing mold
。VOC Combustion control
。Corrosive temperature measurement
。Air/oil pressure machine
。Solar production equipment
。Desalination equipment
。Vehicle material research
。Equipment construction
。Boat, bridge structure
。Building structure monitoring
。Building structure
。Equipment safety detection
。Mechanical vibration measurement
。Structural vibration analysis measurement
。Vibration reduction test
。Machine rigidity test

For more information, please visit    SG-3000 Series

DN-800 / DNM-800 series is a Voltage Attenuator and Current Transformer designed for used in high-voltage and high-current applications . The high-voltage and high-current can be converted into ±10 Vpp attenuated signal, and PET-7H16M/PET-7H24M is able to read the ±10 VDC signals via DN-800 / DNM-800 series. By using DN-800 / DNM-800 series and PET-7H16M/PET-7H24M, the power data of all kinds of machines and AC/DC motors can be high-speed measured and retrieved, and then the analyzed data can be quickly used to develop a model to build a failure warning system.

For more information, please visit    DN-800/DNM-8000 Series

PET-7H16M is equipped with a voltage attenuator and current transformer module (DNM-800) to collect the voltage and current signals of the motor and convert them into analog voltages in the general measurement range. The signals are converted into digital data via the PET-7H16M and transmitted back to the host PC via Ethernet. . On the PC side, the voltage, current, frequency, energy consumption, harmonics and health status of the motor in operation are calculated through algorithms, and the data results are displayed on the HMI to help customers monitor the energy consumption and health status of the motor at all times. It is currently used in a technology company, deploying 9 sets of PET-7H16M to monitor 9 sets of motor equipment. The AI sampling rate of each channel of this application is 2k~10k Hz.

PET-AR400

PET-AR400 is a 24-bit high-performance dynamic signal acquisition Ethernet module specially designed for vibration monitoring and analysis. The maximum simultaneous sampling rate per channel on the PET-AR400 is up to 32kHz. The PET-AR400 module includes a built-in 4mA excitation current to power a piezoelectric (IEPE) accelerometer for collecting real-time vibration data and immediately transmitting the data via Ethernet to a central management system. The analysis software of the system obtains the vibration signal of mechanical equipment, and can use time domain analysis parameters or frequency domain analysis of its acceleration/velocity/displacement amplitude, frequency, etc. to diagnose the strength of the equipment structure, and the operating status of the equipment as an instant alarm or predictive failure Analysis applications such as maintenance.