GW-7434D-G

Modbus TCP/RTU/ASCII Slave to DeviceNet Master Gateway
GW-7434D-G
GW-7434D-G
GW-7434D-G
GW-7434D-G

Features

  • Programmable DeviceNet Master MAC ID
  • Programmable DeviceNet transfer-rate 125K, 250K, 500K
  • Supports maximum DeviceNet devices up to 63
  • Predefined Master/Slave Connection Set
  • Devicenet I/O Length: 128 bytes max. (Input/Output) per DeviceNet slave
  • Total DeviceNet I/O Length: 1280 bytes max. (Input/Output) for all DeviceNet slaves
  • Supports I/O Operation Mode: Poll, Bit-Strobe and Change Of State/Cyclic
  • Supports maximum 512 bytes Modbus I/O datas for DeviceNet I/O to map
  • Supports on-line adding device into and removing device from network
  • Converters single Modbus/TCP to multi Modbus/RTU, setting by Utility
  • Supports VxComm technique for every COM ports of controllers, setting by Utility
  • Allowed multi-client (or master) access simultaneously
  • Supports Modbus RTU to DeviceNet master, setting by Utility
CE UKCA FCC RoHS WEEE

Introduction

The GW-7434D is an economic solution that provides a communication protocol transformation between the DeviceNet protocol and the Modbus TCP protocol. This module solves the problem to connect an existing DeviceNet network to the Ethernet-based PLC, HMI or SCADA for setting up a control or monitoring system. Different to the GW-7243D, the GW-7434D offers the Predefined Master connection Set function and Group 2 only Server function as a DeviceNet master, and enables accessing the DeviceNet slaves automatically and cyclically. If the PLC, HMI or SCADA would like to access the DeviceNet slaves and simultaneously communicate with the Modbus slaves or COM-based devices connected with the RS-232 or RS-485 port of the GW-7434D, the GW-7434D can be the Modbus TCP server or VxComm server to exchange the data with those devices.

Applications

DeviceNet Gas Valve Station (EN)

Robotic Arm Control (TC)

Robotic Arm Control (EN)

Touched HMI Aplications (EN)
 

Typical Applications 

Application 1: Modbus TCP/RTU slave to DeviceNet master gateway

The GW-7434D can act as a Modbus TCP/RTU slave to DeviceNet master gateway. Using the module, users don’t need to take care of the detail of the DeviceNet protocol. The module will implement the DeviceNet protocol automatically. It mainly supports the Predefined Master/Slave Connection Set functions to allow users to merge I/O data into DeviceNet network by using Modbus TCP/RTU commands.

Application 2: a single Modbus/TCP to multi-Mosbus/RTU converter

GW-7434D can be a single Modbus/TCP to multi-Modbus/RTU converter. You can simple use the Utility software to configure the device and then set connection between SCADA, HMI software and the GW-7434D.

Application 3: protocol converter with VxComm technique

GW-7434D can also be able to link to serial devices that don’t support Modbus/RTU. To use this function, you will need to install VxComm driver on host PCs. After installation, you will be able to access the remote COM ports via the standard serial driver.

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES GW-7434D-G     CR DESCRIPTIONModbus/TCP server to DeviceNet Master Gateway (RoHS)
This combination include other products.

Similar Products

CPU Module
CPU 80186, 80 MHz or compatible
EEPROM 16 KB
Watchdog Timer Yes
LED Indicators
Status 1 x Device status
2 x DeviceNet status
Ethernet
Ports 1 x RJ-45, 10/100Base-T(X) (Auto-negotiating, Auto_MDIX)
Protocol Modbus TCP
COM Ports
Ports 1 x RS-232
1 x RS-485
Protocol Modbus ASCII / Modbus RTU
Parity None, Even, Odd
Data Bit 7, 8
Stop Bit 1, 2
DeviceNet
Controller NXP SJA1000T with 16 MHz clock
Ports 1
Connection Supported 1 connection for Explicit Messaging
1 connection for Polled I/O
1 connection for Bit-Strobe I/O
1 connection for COS/Cyclic I/O
Isolation 1000 VDC for DC-to-DC, 2500 Vrms for photo-couple
Terminal Resistor Jumper for 120 Ω terminal resistor
Specification Volume I, Release 2.0 & Volume II, Release 2.0
Power
Input Range +10 VDC ~ +30 VDC
Consumption 2.5 W
Mechanical
Dimensions (mm) 72 x 122 x 33 (W x L x H)
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 ℃
Storage Temperature -30 ~ +80 ℃
Humidity 10 ~ 90% RH, Non-condensing

We provide GW-7434D Utility tools for Windows 98/SE/2K/XP, it includes:

  • Online add/remove DeviceNet devices via Ethernet
  • Online monitor and configure devices status via Ethernet
  • Get/Set Modbus/TCP input/output memory address
  • Support DeviceNet I/O mapping table
  • Show DeviceNet devices connection status
  • Support communication mode setting

Data Interchange 

The GW-7434D provides centralized data storage, “Internal Memory”, for data that is shared between the DeviceNet and Modbus/TCP network. Data is placed into the “Internal Memory” by one network interface, allowing the data to be read/wrote through the other network interface.