GW-5493

BACnet/IP to Modbus TCP Gateway
GW-5493
GW-5493

Features

  • Read/Write Modbus registers via BACnet objects
  • Configurable BACnet/IP Server
  • Configurable Modbus TCP Client
  • Supports up to 200 Objects every type, AI, AO, AV, BI, BO, BV, MSI, MSO, MSV
  • Supports Modbus discrete inputs, coils, input registers and holding registers
CE FCC RoHS WEEE

Introduction

GW-5493 is a fully configurable universal Modbus RTU to BACnet/IP gateway. The GW-5493 includes BACnet/IP Server and Modbus TCP Client which is used to make Modbus TCP devices accessible on a BACnet network. BACnet (Building Automation and Control Networking) protocol has been designed specifically to meet the communication needs of building automation and control systems for applications such as heating, ventilating, air-conditioning control…etc. The GW-5493 contains a large number of BACnet objects (AI, AO, AV, BI, BO, BV, MSI, MSO, MSV) gives you flexibility in mapping Modbus RTU registers to any combination of BACnet objects. Multiple BIBBs (DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM, DS-COV-B…etc.) are supported. All the data transfer is configurable using a standard Web browser.

Applications

  • Building Automation
  • Heating, Ventilating, and Air-conditioning Control
  • Lighting Control
  • Access Control
  • Fire Detection Systems

Ordering Information

PRODUCT SERIES DESCRIPTION QNT. INQUIRY
PRODUCT SERIES GW-5493     CR DESCRIPTIONBACnet/IP to Modbus TCP Gateway (RoHS)
This combination include other products.

Similar Products

CPU Module
CPU 32-bit
EEPROM 16 KB
Flash 64 MB
SRAM 64 MB
Ethernet
Ports 10/100Base-TX Ethernet Controller
COM Ports
Ports RS-232 (RxD, TxD, and GND); Non-isolation
BACnet/IP
Protocol Modbus TCP Client
Objects AI, AO, AV, BI, BO, BV, MSI, MSO, MSV (Maximum: 200 each)
BIBBs DS-RP-B, DS-RPM-B, DS-WP-B, DS-WPM-B, DS-COV-B, DM-DDB-B, DM-DOB-B, DM-DCC-B, DM-TS-B, DM-UTC-B, DM-RD-B
Power
Input Range +10 ~ +30 VDC
Consumption 4.8 W (0.2 A @ 24 VDC)
Mechanical
Casing Plastic
Dimensions (mm) 91 x 132 x 52
Installation DIN-Rail
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +85 °C
Humidity 5 ~ 90% RH, Non-condensing
  • Configured via standard web browser
  • Provide Modbus network configuration interface
  • Provide BACnet configuration interface

Comparison Table

ICP DAS Fieldbus Gateway Comparison Table:
Model Support Protocol Comm. Interface
GW-5492 BACnet/IP Server Modbus RTU Master RS-232
RS-485
Ethernet
GW-5493 BACnet/IP Server Modbus TCP Client RS-232
Ethernet
GW-7228 J1939 Modbus RTU Slave RS-232
RS-422
RS-485
GW-7433D CANopen Master Modbus TCP Server/RTU Slave RS-232
RS-485
Ethernet
I-7231D CANopen Slave DCON Master RS-232
RD-485
I-7232D CANopen Slave Modbus RTU Master RS-232
RD-485
I-7241D DeviceNet Slave DCON Master RS-232
RD-485
I-7242D DeviceNet Slave Modbus RTU Master RS-232
RD-485
I-7243D DeviceNet Master Modbus TCP Server Ethernet
GW-7243D DeviceNet Slave Modubs TCP / RTU / ASCII Master RS-232
RS-422
RS-485
GW-7552 PROFIBUS DP-V0 Slave Modubs RTU/ASCII Master/Slave RS-232
RD-485
GW-7553 PROFIBUS DP-V0 Slave Modbus TCP / RTU/ ASCII Maste / Slave RS-232
RD-485