PM-3133-RCT2000P Series – Modbus RTU, 3-phase power meter, with Rogowski Coil CT

New Products 2020-08-26

PM-3133-RCT2000P - Modbus RTU, 3-phase power meter; includes 2000A CT (Inside diameter 105 mm; wire lead 4 m) x 3
PM-3133-RCT4000P - Modbus RTU, 3-phase power meter; includes 4000A CT (Inside diameter 185 mm; wire lead 4 m) x 3
PM-3133-RCT2000P-MTCP - Modbus TCP, 3-phase power meter; includes 2000A CT (Inside diameter 105 mm; wire lead 4 m) x 3
PM-3133-RCT4000P-MTCP - Modbus TCP, 3-phase power meter; includes 4000A CT (Inside diameter 185 mm; wire lead 4 m) x 3




 

Introduction:

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3133-RCT that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<2%, PF=1; Input Current >50A), this series can be used to both low voltage primary side and medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters monitoring equipment with Rogowski Coil CT is "ropestyle" Current Transformer which delivers "Easy Installation" features for large window size (55 ~ 185mm) and mechanical flexibility for tight space. It operates over a wide range of input voltages 10 ~ 500 VAC which allows universal compatibility. Also, with 2 channels built-in relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration. 

 

Features:

  • Bi-directional Energy
  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Current Measurements Up to 500 ~ 4000 A
  • Voltage Measurements Up to 500 V
  • Rogowski Coil Soft CT for Easy Installation
  • W Accuracy Better than 2% (PF=1 Input Current >50A)
  • Total Harmonic Distortion (THD)
  • RS-485 or Ethernet (PoE) Communication
  • Supports Modbus RTU/TCP Protocol
  • Builit-in 2 Power Relay Output (Form A)
  • IEC 61010-1 and EN 61010-1
 

Similar Products:

Model Name PM-2133D-xxxP PM-3033 PM-3133-xxxP PM-3133i-xxxP PM-3133-RCTxxxP
Spotlight With LED Display To secondary output Generic Isolated Rogowski Coil
Wiring 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Max. Voltage 500V 500V 500V 600V 500V
Max. Current Includes Clip-on CT,
CTΦ10 mm (60 A),
CTΦ16 mm (100 A),
CTΦ24mm (200 A),
CTØ36 mm (300 A),
CTØ36 mm (400 A)
without CT,
1A or 5A
Includes Clip-on CT,
CTΦ10 mm (60 A),
CTΦ16 mm (100 A),
CTΦ24mm (200 A),
CTØ36 mm (300 A),
CTØ36 mm (400 A)
Includes Clip-on CT,
CTΦ10 mm (60 A),
CTΦ16 mm (100 A),
CTΦ24mm (200 A),
CTØ36 mm (300 A),
CTØ36 mm (400 A)
Includes Rogowski Coil type CT,
CTΦ55 mm (500 A),
CTΦ80 mm (1000 A),
CTφ105 mm (2000A) (New),
CTφ185 mm (4000A) (New)