/***************************************************/ /* Modbus Utility */ /* For 8430/8830/8431/8831/8KE4/8KE8 */ /* 7188E/iP-8000/ET-87Pn/ET-8KPn MTCP series */ /***************************************************/ ------------------------------------------------------------------------ Version: 1.8.5 [2021/06/30] by Mac NEW Support moving average for I-8017HW, I-8017HCW, I-8014W and I-8026W. Set fifo number 5~50 to acvtive moving average. The process will remove the highest and lowest values, and then caculate the average. Support I-87026W, I-8026W, I-87084W. Support duty setting of I-8088W(8-ch PWM output module). Add module off-line configuration files in Modbus_Utility\Demo Users can load the configuration files to check the configuration screens of various modules. Update eSearch V1.2.6 09,Dec,2020 Fix the bug that sometime can not search the PAC when the PC has multiple Ethernet adapters. ========== Relative information for 8000E-MTCP ========== The gateway and I/I units do not come with a CD. The firmware are uploaded to the website. You can get the firmware in the download center of each gateway and I/O unit. ------------------------------------------------------------------------------------- Units Firmware MiniOS7 image ------------------------------------------------------------------------------------- I-8KE4-MTCP, I-8KE8-MTCP M8E17270.EXE c836_udp-20210525.img ------------------------------------------------------------------------------------- iP-8441-MTCP, iP-8841-MTCP M8A17270.EXE C837_2M_UDP-20190905.img ------------------------------------------------------------------------------------- ET-87P4-MTCP, ET-87P8-MTCP M8T17270.EXE C837A_20190918.img (support only 87K modules) ------------------------------------------------------------------------------------- ET-8KP4-MTCP, ET-8KP8-MTCP ET8K7270.EXE C837A_20190918.img (support 8K, 87K modules) ------------------------------------------------------------------------------------- iP-8411-MRTU, iP-8811-MTCP M8R17270.EXE C837_2M_UDP-20190905.img ------------------------------------------------------------------------------------- ------------------------------------------------------------------------ Version: 1.8.4 [10,Nov,2017] by Renee NEW Support ET-8KPn-MTCP. Add Modbus "I/O Update time" and dispaly in the AI Mapping pane.(Current, maximum, minimum value in millisecond) -To achieve the I/O update time, the firmware need to update to 17267 first. Add "Reset I/O Update time" and set in the DO Mapping pane. Fix Bug Correct DI Counter address repeat if there are more than one DI Counter module. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E CD:\Napdos\Modbus\8000E\Firmware\M8e17267\M8E17267.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20121022.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20150520.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for iP-8441-MTCP, iP-8841-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17267\M8A17267.EXE MiniOS7 image file: CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20160826.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87P4-MTCP, ET-87P8-MTCP (support only 87K modules) CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17267\M8T17267.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\C837_2M_UDP-20160826.img ========== Relative information for ET-8KPn-MTCP ========== Modbus firmware: for ET-8KP4-MTCP, ET-8KP8-MTCP (support 8K, 87K modules) CD:\Napdos\Modbus\ET8KPn\Firmware\et8k7267\et8k7267.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET8KPn\OS_Image\C837_2M_UDP-20160826.img ========== Relative information for iP-8000-MRTU ========== Modbus firmware: for iP-8411-MRTU, iP-8811-MTCP CD:\Napdos\Modbus\iP8000R\Firmware\M8R17265\M8R17267.EXE MiniOS7 image file: CD:\Napdos\Modbus\iP8000R\OS_Image\C837_2M_UDP-20121025.img ------------------------------------------------------------------------ Version: 1.8.3 [17,Oct,2016] by Renee Update uPAC-7186EX-MTCP: change displayed name form I-7186En to uPAC-7186EX-MTCP. Enable Mode: remove "Console" item ,add "Modbus RTU-to-RTU Gateway" item and change "Modbus/RTU Gateway" to "Modbus TCP-to-RTU Gateway". The "Modbus RTU-to-RTU Gateway" only support for firmware version 1.7.5 or later. Version: 1.8.2 [06,Mar,2015] by Mac Update Fix range code for I-870278U. Version: 1.8.1 [28,Mar,2014] by Renee NEW Support I-87028VW, I-87028-20VW, I-87005W Support update firmware, set network and date/time[under initial mode]. -You can click "Client Tools">"Update Firmware" to do above setup via Ethernet or RS-232 cable. -If controller already had previous firmware, you can click "Erase Disk" before updating firmware. Support backup and recover setting[under initial mode and connect by RS-232 cable]. -You can click "Client Tools">"Update Firmware" and connect. Back up Settings can save current configuration as a ".eep" file to your PC. Recover Settings can load ".eep" file form PC and write to controller. For different type of controller, it has different writable blocks. For 7188E : 1 - 7 are writable blocks. For 8000E : 1 - 7 are writable blocks. For iP-8000 : 8 - 14 are writable blocks. Update For Win 7/8 user, the application will check if it's running as administrator. "Client Tools" > "UDP Search" is using eSearch Utility instead of UDPSearch.exe. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E CD:\Napdos\Modbus\8000E\Firmware\M8e17265\M8E17265.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17265\M8A17265.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20121025.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87Pn-MTCP CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17265\M8T17265.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\c837_2m_udp-20111108.img ========== Relative information for iP-8000-MRTU ========== Modbus firmware: for iP-8000-MRTU CD:\Napdos\Modbus\iP8000R\Firmware\M8R17265\M8R17265.EXE MiniOS7 image file: CD:\Napdos\Modbus\iP8000R\OS_Image\C837_2M_UDP-20121025.img ------------------------------------------------------------------------ Version: 1.8.0 [06,Aug,2013] by Mac NEW Support iP-8811-MRTU, iP-8411-MRTU, the remote I/O unit. Support I-87028UW, I-87028CW Support I-8093W on iP-8000 Support I-8014W Update Read Index of I-8090 QUADRANT mode. The index value is saved in DI register. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e17264\M8E17264.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17264\M8A17264.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20121025.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87Pn-MTCP CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17264\M8T17264.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\c837_2m_udp-20111108.img ========== Relative information for iP-8000-MRTU ========== Modbus firmware: for iP-8000-MRTU (new) CD:\Napdos\Modbus\iP8000R\Firmware\M8R17264\M8R17264.EXE MiniOS7 image file: CD:\Napdos\Modbus\iP8000R\OS_Image\C837_2M_UDP-20121025.img ------------------------------------------------------------------------ Version: 1.8.0 [06,Aug,2013] by Mac NEW Support iP-8811-MRTU, iP-8411-MRTU, the remote I/O unit. Support I-87028UW, I-87028CW Support I-8093W on iP-8000 Support I-8014W Update Read Index of I-8090 QUADRANT mode. The index value is saved in DI register. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e17264\M8E17264.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17264\M8A17264.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20121025.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87Pn-MTCP CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17264\M8T17264.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\c837_2m_udp-20111108.img ========== Relative information for iP-8000-MRTU ========== Modbus firmware: for iP-8000-MRTU (new) CD:\Napdos\Modbus\iP8000R\Firmware\M8R17264\M8R17264.EXE MiniOS7 image file: CD:\Napdos\Modbus\iP8000R\OS_Image\C837_2M_UDP-20121025.img ------------------------------------------------------------------------ Version: 1.7.3 [15,Oct,2012] by Mac New Support UDP Search. You can click "Client tools"=>"UDP Search" to run UDP search program. You can search the controller and set it's IP address by the program. Update Add 4~20mA, 0~20mA type of 87019. Add Pt1000 types of 87015. Fix Bug Support 32 channel DI Counter setting for 87040. Correct the mornitoring values for 4~20mA type of 87017Z. Correct the mornitoring values for -50~50V type of 87017W-A5. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e17263\M8E17263.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17263\M8A17263.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20110921.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87Pn-MTCP (new) CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17263\M8T17263.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\c837_2m_udp-20111108.img ------------------------------------------------------------------------ Version: 1.7.2 [2012/06/27] by Mac New Support ET-87Pn-MTCP Ethernet I/O expansion unit. Support 8046W,87015PW,87016W,87017W-A5,87017RW87017RCW,87017DW, 87017DW-SE,87018RW,87018PW,87019PW,87037W,87040PW,87042W, 87053PW,87053W-A5,87053W-E5,87057PW,87059W,87069W 8017DW,8017HCW,I-87024DW,I-87024RW,I-8050W modules. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e17262\M8E17262.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000-MTCP CD:\Napdos\Modbus\IP8000\Firmware\M8A17262\M8A17262.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20110921.img ========== Relative information for ET-87Pn-MTCP ========== Modbus firmware: for ET-87Pn-MTCP (new) CD:\Napdos\Modbus\ET87Pn\Firmware\M8T17262\M8T17262.EXE MiniOS7 image file: CD:\Napdos\Modbus\ET87Pn\OS_Image\c837_2m_udp-20111108.img ------------------------------------------------------------------------ Version: 1.7.2 [2012/01/03] by Mac New Support IP-8841/8441 main control unit. Support I-87017ZW, I-87019ZW, I-87018ZW, I-8084W module. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e17260\M8E17260.EXE MiniOS7 image file: 8000E (40M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP-20110125.img 8000 (80M CPU) CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20110117.img ========== Relative information for IP-8000-MTCP ========== Modbus firmware: for IP-8000 (new) CD:\Napdos\Modbus\IP8000\Firmware\M8A17260\M8A17260.EXE MiniOS7 image file: IP-8000 (80M CPU) CD:\Napdos\Modbus\IP8000\OS_Image\C837_2M_UDP-20110921.img ------------------------------------------------------------------------ Version: 1.7.0 [15,Jul,2007] by Mac ===== For 8000E-MTCP ===== Support 87019 Support Modbus/ASCII Slave COM Port Mode Configuration ------------------------------------------------------------------------ Version: 1.6.9 [21,May,2007] by Mac ===== For 8000E-MTCP ===== Support 87022,87026 ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e16956\M8E16956.EXE MiniOS7 image file: 8000E (40M CPU) 2.02 build 002, Apr 9 2007 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8000_UDP_20070409.img 8000 (80M CPU) 2.02 build 002, Apr 9 2007 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\C836_UDP-20070409.img ------------------------------------------------------------------------ Version: 1.6.8 [16,Aug,2006] by Mac ===== For 8000E-MTCP ===== New function 1.Set analog/digital output power on value, safe value 2.Read/Set watchdog timer, WDT event counts, CPU reset status, CPU reset events Fixbug:Set all range code error AI/AO(since V1.6.7) ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8e16755\M8E16755.EXE MiniOS7 image file: For 8000E (40M CPU) 2.00 build 004, Sep 02 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K050902.img For 8000E (80M CPU) 2.01 build 000, Nov 03 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8000E-80-20051103.img ------------------------------------------------------------------------ Version: 1.6.7 [20,Jul,2006] by Mac ===== For 8000E-MTCP ===== fix bug:DI Counter list error on AI mapping table. fix bug:Address table error of data logger list for 8080. fix bug:Address mapping error of 8090 on DO/AI mapping table. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\M8E16654\M8E16654.EXE MiniOS7 image file: For 8000E (40M CPU) 2.00 build 004, Sep 02 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K050902.img For 8000E (80M CPU) 2.01 build 000, Nov 03 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8000E-80-20051103.img ------------------------------------------------------------------------ Version: 1.6.6 [4,Jul,2006] by Mac ===== For 8000E-MTCP ===== New function 1.Auto scan I/O value monitor Add a column to show the I/O value in mapping table. On menu bar "Setting"=>"Monitor" to enable monitor or to set scan time interval 2.Digital/Analog output control Double click the address grid of digital/analog output mapping table to change the output value. 3.On/Off line warring of 87K module If the module is off line, the picture on the unit will become a red one, and come back normal when the module is on line. 4.COM Port setting The COM Port setting is the same function of 7188-MTCP. Five modes can be setted of the COM Port: a.VxComm (Virtual COM) b.Modbus/RTU Gateway c.Programming d.UpLink e.Debug 5.Datalog On menu bar "Setting" =>"Log" to enable log, open log file, or set log file name. If the log file name is not setted, default file name is "yyyymmdd.txt" at subdirectory "log". 6.Trend line There are 1 analog track and 3 digital tracks on the scope form. Click menu bar "Setting"=>"Trend" to show. 7.Set output value in scope Click on I/O or Address grid in address list to set. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\Ver_166\MBT8_166.exe MiniOS7 image file: For 8000E (40M CPU) 2.00 build 004, Sep 02 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K050902.img For 8000E (80M CPU) 2.01 build 000, Nov 03 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8000E-80-20051103.img ------------------------------------------------------------------------ Version: 1.5.1 Beta [8,May,2006] by Kevin ===== For 8000E-MTCP ===== Support 1. RTD Input Module:87015. ------------------------------------------------------------------------ Version: 1.5.0 [23,Mar,2006] by Kevin ===== For 8000E-MTCP ===== Support 1. Low speed counter (100Hz) of 87K DI module. 2. 16 Channel reading of 8017HS single-end mode New function Auto configuring When replaceing a module with another one (with same module ID number), the configuration will be keep the same as the data stored on the CPU module. This is helpful when replacing a damaged module, the worker doesn't need a PC to run Modbus Utility to configure the new module again. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\Ver_150\MBT8_150.exe MiniOS7 image file: For 8000E (40M CPU) 2.00 build 004, Sep 02 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K050902.img For 8000E (80M CPU) 2.01 build 000, Nov 03 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8000E-80-20051103.img ------------------------------------------------------------------------ Version: 1.3.3 [05,May,2005] by Kevin ===== For 7188E-MTCP ===== Change mapping for Modbus/RTU gateway refer the revison information of the online help for details. ========== Relative information for 7188E-MTCP ========== Modbus firmware: for 7188E (updated) CD:\Napdos\Modbus\7188E\Firmware\Ver_161\MBT7_161.exe MiniOS7 image file: for 7188E (40M CPU) 2.00 build 002, Oct 11 2004 CD:\Napdos\Modbus\7188e\OS_Image\For_40M\e041011.img ------------------------------------------------------------------------ Version: 1.3.2 [13,Apr,2005] by Kevin ===== For 8000E-MTCP ===== Support 87040, 87041 ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E (updated) CD:\Napdos\Modbus\8000E\Firmware\Ver_135\MBT8_135.exe MiniOS7 image file: for 8000E (40M CPU) (updated) 2.00 build 002, Apr 08 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K050408.img for 8000E (80M CPU) (updated) 2.00 build 002, Apr 08 2005 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8E050408.img ------------------------------------------------------------------------ Version: 1.3.1 [05,Jan,2005] by Kevin ===== For 8000E-MTCP ===== Fix bug DI registers of online/offline status oeverlap the DI modules. The firmware of I-8000E is no problem, users only need to update the Modbus Utility. Version: 1.3.1 [24,Dec,2004] by Kevin ===== For 8000E-MTCP ===== Add online/offline status detection for each I/O module. When the module is alive, the DI register is 1. If the module is failed, the DI register becomes 0. Support 8080 Fix bug Option to set offset value to AI moudle is ok, but to AO module doesn't work. ========== Relative information for 8000E-MTCP ========== Modbus firmware: for 8000E CD:\Napdos\Modbus\8000E\Firmware\Ver_131\MBT8_131.exe MiniOS7 image file: for 8000E (40M CPU) 2.00 build 001, Mar 30 2004 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K040330.img for 8000E (80M CPU) 2.00 build 001, Apr 20 2004 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8E040420.img ------------------------------------------------------------------------ Version: 1.2.7 [11,Jun,2004] by Kevin Add function Add CJC enable/disable functions for 87018 in 8000E-MTCP. ========== Relative information ========== Modbus firmware: for 8000E CD:\Napdos\Modbus\8000E\Firmware\Ver_121\MBT8_121.exe MiniOS7 image file: for 8000E (40M CPU) 2.00 build 001, Mar 30 2004 CD:\Napdos\Modbus\8000e\OS_Image\For_40M\8K040330.img for 8000E (80M CPU) 2.00 build 001, Apr 20 2004 CD:\Napdos\Modbus\8000e\OS_Image\For_80M\8E040420.img ------------------------------------------------------------------------ Version: 1.2.6 [25,Nov,2003] by Kevin Support 7188E-MTCP version 1.5.5 Fix bug when save/load configuration of 7188E-MTCP to/from *.ini files. Update MBRTU.exe to version 1.05 improve communication performance in polling mode Update MBTCP.exe to version 1.1.3 add an option to log the communication data to a text file. Note: this version doesn't support old version 7188E firmware. ========== Relative information ========== Modbus firmware: for 7188EX CD:\Napdos\Modbus\Firmware\7188E\ModbusTCP\Ver_155\MBT7_155.exe MiniOS7 image file: for 7188EX 2.00.001 , May 29 2003 CD:\Napdos\Modbus\OS_Image\7188e\e-030529.img ------------------------------------------------------------------------ Version: 1.2.5 [23,Sep,2003] by Kevin Modify AI adjustment option (for 8000-MTCP only): AI offset range is chnaged from this verion. The difference is: -128 ~ +127 ===> Utility: 1.2.3 ~ 1.2.4 Firmware: 1.1.5 ~ 1.1.9 -10000 ~ +10000 ===> Utility: 1.2.5 ~ newer Firmware: 1.2.0 ~ newer Add check-verion function Different firmware version supports different options. With the check-version function, the Utility can to recognize the firmware version and then decide which button and text box should be included. Support 8037 (for 8000-MTCP only) ========== Relative information ========== Modbus firmware: MBT8_120.exe to support new AI offset adjustment option to support 8037 MiniOS7 image file: for 8000-MTCP 2.00 build 001, Jun 05 2003 CD:\Napdos\Modbus\OS_Image\8000E\8K030605.img ------------------------------------------------------------------------ Version: 1.2.4 [11,Jul,2003] by Kevin (Not released to all user) Open function (for 7188E-MTCP only) Let users can change COM port settings of 7188E when the COM port is set to Modbus/RTU mode. Change label (for 7188E-MTCP only) Change label "Station/COM port" of the 7188E to "Stations per COM port". The document also do some change of description of the label. ------------------------------------------------------------------------ Version: 1.2.3 [20,Jun,2003] by Kevin Add AI offset adjustment option (for 8000-MTCP only) When you use AI modules, there must have difference between channels or slots. The differences could be caused of 1. sensor 2. power 3. environment noise 4. temperature 5. component of modules The QG procedure cannot guarantee the analog input values of every channel and every slot are same because above factors. The best method is: adjust the offsets of every channel and every slot to get almost same values (measure same target) at the work place at first time. Note: MBTCP_8E.exe must be version 1.1.6 ------------------------------------------------------------------------ Version: 1.2.2 [26,Jun,2003] by Kevin Upgrade MBRTU.exe (Modbus/RTU client) to version 1.0.4 MBTCP.exe (Modbus/TCP client) to version 1.1.2 Add polling mode to send command. That can estimate the communication performance. ------------------------------------------------------------------------ Version: 1.2.2 [27,May,2003] by Kevin Support: 8077, 8090 Note: MBTCP_8E.exe must be version 1.1.4 ------------------------------------------------------------------------ Version: 1.2.1 [20,Mar,2003] by Kevin Fix bug: When link to 87013, the first 4 channels of the AI module that next to the 87013 are always zero. Note: MBTCP_8E.exe must be version 1.1.3 ------------------------------------------------------------------------ Version: 1.2.0 [14,Mar,2003] by Kevin Support I-7188E -MTCP Add CJC adjustment for 87018. Note: MBTCP_8E.exe must be version 1.1.2 ------------------------------------------------------------------------ Version: 1.0.3 [8,Oct,2002] by Kevin Update Modbus Utility to ver. 1.0.3 to support Modbus/TCP ver. 1.0.1 (of 8000E). Addtion functions: 1. lists relate libaries version in help ==> about. ------------------------------------------------------------------------ Version: 1.0.1 [25,Sep,2002] by Kevin